Nelsen Corporation AIO Plus Connected Series Installation & Operation Manual

Advertisement

Installation & Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Nelsen Corporation AIO Plus Connected Series

  • Page 1 Installation & Operation Manual...
  • Page 2: Table Of Contents

    Index AIO Plus Connected Series General Warnings Page 1 ..............................................Installation Requirements Page 2 - 4 ..........................................Installation Procedure Page 5 ............................................Utilizing Bluetooth Page 6 - 8 ..............................................Programming the Control Valve Page 9 - 11 ....................................... Powerhead Assembly Page 12 ............................................
  • Page 3: General Warnings

    AIO Plus Connected Series General Warnings WARNING Lubricants Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants will cause swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl . It is recommended ®...
  • Page 4: Installation Requirements

    Installation Requirements AIO Plus Connected Series INSTALLATION REQUIREMENTS Locate a level floor position ahead of piping into water heater for placement. Unit must be installed at least 10 feet ahead of the inlet to a water heater to prevent damage due to back-up hot water.
  • Page 5 AIO Plus Connected Series Installation Requirements INSTALLATION PROCEDURE Water Supply Connection and Bypass Valve To allow for filter servicing, swimming pool filling or lawn sprinkling, a manual Bypass Valve has been installed at the factory. The Bypass allows raw water to be manually routed around the filter.
  • Page 6: Installation Requirements

    Installation Requirements AIO Plus Connected Series Electrical Connection 1. Connect the power cord and plug power supply into a 120 volt / 60 Hz receptacle. NOTE: Do not plug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off...
  • Page 7: Installation Procedure

    AIO Plus Connected Series Installation Procedure Final Check 1. Be certain that the bypass valve is in Service position and main valve is completely on. 2. Check electrical supply to be certain the cord is connected to an uninterrupted 120 volt outlet.
  • Page 8: Utilizing Bluetooth

    Utilizing Bluetooth Control AIO Plus Connected Series ® up, or there is a problem connecting to a device, you can press the “Scan for Devices” button or the Legacy View logo at any time to refresh the list and start the process over.
  • Page 9 AIO Plus Connected Series Utilizing Bluetooth Control ® 1. Set Unit Time (Press “ok” to set time automatically based on device time). 2. Set Filter Backwash Frequency - This sets the number of days between backwash cycles. 3. Set Regeneration Time - Example: Midnight, just type 12 then press OK.
  • Page 10: Utilizing Bluetooth

    Utilizing Bluetooth Control AIO Plus Connected Series ® Status and History From the Status and History, all items in ORANGE can be reset. Touch any table to explode a detailed list of the last 60 days. 1. Start a regeneration or backwash cycle Option 1: Click the “Regenerate Unit Now.”...
  • Page 11: Programming The Control Valve

    AIO Plus Connected Series Programming the Control Valve Main Menu 12:00 MENU/ENTER SET/CHANGE 1. To enter Main Menu, press the Menu/Enter button. (Time of Day will flash) 2. To set the Time of Day, press the Set/Change button. Example: (12:00) (First digit will flash) - To change digit value, press the Set/Change button.
  • Page 12 Programming the Control Valve AIO Plus Connected Series Normal Operation 1. Home Display a. Alternates between the display of Time of Day and Number of Days until the Next Backwash. (Metered Softeners will alternate between time of days and gallons remaining until next regeneration).
  • Page 13: Programming The Control Valve

    AIO Plus Connected Series Programming the Control Valve Starting Extra Regeneration Cycle Example: [1] 1. To Start Delayed Extra Cycle: - If Days Remaining Until Next Regeneration does not read ‘1’, press and hold the Set/Change button for 3 seconds until the display reads ‘1 - Regeneration cycle will initiate at the next designated regeneration time.
  • Page 14: Powerhead Assembly

    Powerhead Assembly AIO Plus Connected Series LETTERS IN DIAGRAM REPRESENT WIRING CONNECTIONS Description Part# Powerhead Assembly 20010N100 Circut Board Assembly CS-BOARD ENCLOSURE 1 Encoder 20001X124 Front Plate 20001X004 Encoder Wheel 20001X007 Main Gear 21001X120 Power Supply CS-TRANS Back Plate 20001X005...
  • Page 15: Valve Body Assembly

    AIO Plus Connected Series Valve Body Assembly VALVE PARTS LIST ON FOLLOWING PAGE...
  • Page 16: Bypass Assembly

    Valve Body Assembly - Parts AIO Plus Connected Series Bypass Assembly Description Part# Piston Assembly CS-PISTON 10-24 X 13/16 Hex Head 20001X001 Seal and Spacer Kit CS-SEALS Bottom Spacer DLFC 5.0 Button 20251X272 DLFC 7.0 Button 20251X273 Drain Line Flow Control Housing 20017X268...
  • Page 17 AIO Plus Connected Series Servicing Instructions A. General Preliminary Instructions PERFORM BEFORE ALL SERVICING OPERATIONS 1. Turn off water supply to conditioner. • If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the valves at the conditioner inlet and outlet.
  • Page 18: Troubleshooting

    Troubleshooting Guide AIO Plus Connected Series F. To Replace Meter 1. Follow steps A1 - A3. 2. Unplug meter cable from front of circuit board. 3. Unscrew meter assembly nut from valve body. 4. Remove meter from valve body and clean or replace as necessary.
  • Page 19: Error Codes

    AIO Plus Connected Series Error Codes Control Valve Error Code Diagnosis Under normal operating conditions, when the control valve is in the “in service” position, the display should alternate between the current time of day and the number of days remaining (for filters and time clock softeners) or gallons re- maining (for metered softeners) until the next regeneration.
  • Page 20 Warranty is applicable to our product. No repair or replacement Residential Mineral Tank 10 Years made under the terms of the warranty shall extend this AIO Plus Connected Series Control Valve 7 Years warranty. Other Accessories and Parts 1 Years Part No: CS-AIO-PLUS-PROG GUIDE ©Nelsen Corporation - 0619...