Connection
6.1
Mechanical connection of water cooling system
The inlet and outlet holes for the cooling water supply are located on the NDE in the bearing
shield.
1. Make sure that the cooling water fulfills the required cooling water specification, see the
2. Make sure that the appropriate volume of cooling water is available, see the rating plate
3. Attach the cooling water pipes to the cooling water connections. You can connect the inlet
4. Ensure that the maximum permissible operating pressure does not exceed 2.5 bar.
5. Ensure that the cooling water connections and the cooling water pipes are not subject to
Adjusting the outlet direction of the cooling water connection:
1. Remove the union nut from the adjusting bracket
2. Rotate the adjusting bracket to the required output direction
3. Manually fix the adjusting bracket
4. Tighten the union nut to 32 Nm using a torque wrench
See also
Cooling (Page 19)
SIMOTICS A-1FV5/1PV5 synchronous/induction motors
Operating Instructions, 03/2014, 610.45002.40
chapter titled "Cooling".
(type plate).
and outlet as required.
continuous forces.
6
35