INSTALLING THE FIREPLACE

STEP 1: Frame the opening for the fireplace using the dimensions
shown in Figures 1 or 2.
STEP 2: Set the fireplace directly in front of this opening and slide
the unit back until the mounting flanges touch the side framing.
STEP 3: Check the level of the fireplace and shim with sheet metal
if necessary.
STEP 4: When the fireplace is installed upon a combustible floor a
galvanized sheet ember protector (provided) must be installed be-
tween the fireplace and the hearth extension as illustrated in Figures
15 and 16, page 7.
STEP 5: Secure the fireplace to the framing through the nailingflanges
located on the sides on the fireplace with nails or sheet rock screws.
NOTE: The 3/4" clearance is not required at the nailing flange (see
Figure 12, page 6).
f i r e - p a r t s . c o m
45
/
"
1
4
Figure 1 FRAMING DIMENSIONS
46
5
/
"
8
66"
Figure 2 FRAMING DIMENSIONS
55510
11
/
"
3
16
43
1
/
"
2
23
5
/
"
8
15
3
/
"
8
33"
5
12
/
"
8
ASSEMBLING AND INSTALLING YOUR
DOUBLEWALL CHIMNEY SYSTEM
Each double wall chimney section consists of an outer pipe, flue pipe
and one wire spacer. The pipe sections are not unitized and must be
assembled independently as the chimney is installed. When starting
the chimney directly on the fireplace, the flue pipe section must be
installed first, with lanced side up. The outer pipe section can then
be installed over the flue pipe section with the hemmed end up (see
Figure 3).
Press down on each pipe section until the lances securely engage the
hem on the fireplace starter. The wire spacer will assure the proper
spacing between the inner and outer pipe sections.
LINEAL GAIN: THE ACTUAL
MEASURABLE LENGTH OF A
PART AFTER TWO OR MORE
PARTS ARE CONNECTED.
12
3
/
GALVANIZED
8
OUTER PIPE
HEMMED
END
8 IN.
STAINLESS
INNER PIPE
Figure 3
Continue to assemble chimney sections as outlined above, making
sure both inner and outer pipe sections are locked together. When
installing double wall "snap lock" chimney together, it is important
to assure the joint between the chimney sections are locked. Check
by pulling chimney upward after locking. The chimney will not
come apart if properly locked. It is not necessary to add screws to
keep the chimney together.
WARNING: THE OPENING IN THE COLLAR AROUND
THE TOP OF THE FIREPLACE MUST NOT BE OB-
STRUCTED. NEVER USE BLOWN INSULATION TO
FILL THE CHIMNEY ENCLOSURE (SEE FIGURE 4).
FIREPLACE
COLLAR
Figure 4
3
LINEAL GAIN
PART NO.
DESCRIPTION
V42 E/EC
FIREPLACE
V12-8DM
PIPE SECTION
V18-8DM
PIPE SECTION
V24-8DM
PIPE SECTION
V36-8DM
PIPE SECTION
V48-8DM
PIPE SECTION
VRTL-8DM
ROUND
VRTTL-8DM
TERMINATION
VETO-8DM
CHASE
VETLO-8DM
TERMINATION
KEEP THIS
AREA OPEN
GAIN (IN)
42
5
10
/
8
5
16
/
8
5
23
/
8
5
34
/
8
5
46
/
8
6
1 to 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aristocrat v42ec2

Table of Contents