20L Dehumidifier Model Number: RHDH2002 220-240V AC 50Hz 440W For Customer Services & Spare Parts please call 0345 209 7461 https://mda.russellhobbs.com Or visit us at PLEASE RETAIN FOR FUTURE REFERENCE...
CONTENTS Page(s) Safety Instructions and Electrical Safety 3 - 4 Feature Diagram Control Panel Diagram Positioning your Dehumidifier Using your Dehumidifier 8 - 14 Emptying your Dehumidifier 14 - 15 Cleaning and Care 16 – 17 Troubleshooting Guarantee and Customer Services Spare Parts Connection to the Mains Supply Notes...
Safety Instructions Important note: Please read this booklet before installing and switching on this appliance. The manufacturer assumes no responsibility for incorrect installation and usage as described in this booklet. • This model uses natural refrigerant gas as part of its cooling system. This gas is known as R290 (Propane) and is environmentally friendly but can be combustible.
Page 4
Safety Instructions • Do not use in the following locations:- Next to a source of fire. An area where oil is likely to splash. An area exposed to direct sunlight. An area where water is likely to splash. Near a bath, shower or a swimming pool. In a greenhouse.
FEATURE DIAGRAM Front Rear 1. Control panel 6. Drain hose outlet 2. Air outlet grille 7. Air inlet grille 3. Water tank 8. Air filter (behind the air 4. Water tank window intake grille) 5. Handle 9. Power cord buckle 10.
CONTROL PANEL DIAGRAM 1. Power 9. Continuous dehumidifier 2. Mode selection button (extraction) mode indicator 3. Up control button light 4. Down control button 10. Dryer mode indicator light 5. Fan button 11. Water tank full indicator light 6. Timer button 12.
POSITIONING YOUR DEHUMIDIFIER • This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications. • Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full drawer of water. •...
USING YOUR DEHUMIDIFIER When using the dehumidifier for the first time, run the unit in continuous mode for 24 hours When the water tank is full the unit will automatically shut off or when the tank is removed. The fan motor may continue for a period of 30 seconds after shut off, this is normal After the unit has stopped, the unit cannot be restarted for 3 minutes.
Page 9
USING YOUR DEHUMIDIFIER Continuous Dehumifier (Extraction) Mode • For maximum extraction rate, the Continuous Dehumidifier (Extraction) mode should be used. • Press the Mode button on the control panel until the Continuous Dehumidifier indicator light is illuminated • The unit will continue to run at the maximum extraction rate until the water tank reaches the max fill level.
Page 10
USING YOUR DEHUMIDIFIER • Press the Mode button until the Dryer indicator light is illuminated • Press the Power button or Mode button to cancel the dryer function. Note: • The humidity cannot be set when the unit is operating in Dryer Mode.
Page 11
USING YOUR DEHUMIDIFIER Setting the Timer Delayed Start • The unit must be switched OFF for the Auto Start function to be programmed. • With the unit switched off, press the Timer button until the Timer indicator light is illuminated. “0.0” will be displayed on the LED display. •...
Page 12
USING YOUR DEHUMIDIFIER • Control the fan speed by pressing the fan speed button and select from Low, Medium and High fan speed settings. • Set the fan speed to High to obtain the maximum moisture removal. • When the humidity has been reduced and quiet operation is preferred (night time for example), you can set the fan control to Medium or Low.
Page 13
USING YOUR DEHUMIDIFIER Other features Auto Shut Off The dehumidifier will shut off automatically under the following conditions: • When the water tank is full • When the water tank is removed • When the water tank is not replaced in the proper position •...
USING YOUR DEHUMIDIFIER Error Codes AS – Humidity Sensor Error. Unplug the unit and plug it back in. if the error continues, call customer service. ES – Temperature Sensor Error – Unplug the unit and plug it back in. If error continues, call customer service.
Page 15
EMPTYING YOUR DEHUMIDIFIER • When you remove the water tank, do not touch any parts inside of the unit. Doing so may damage the product. • Be sure to push the water tank gently all the way into the unit. Banging the tank against anything or failing to push it in securely may cause the unit not to operate.
CLEANING AND CARE Cleaning the Air Filter The air filter is located behind the air intake grill on the rear of the appliance and should be checked and cleaned at least every 30 days or more often if necessary. NOTE: DO NOT PUT THE FILTER IN AN AUTOMATIC DISHWASHER To Remove the Air Filter: •...
Page 17
CLEANING AND CARE Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. Cleaning the Grille and Case • Use water and a mild detergent. Do not use bleach or abrasives. • Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
TROUBLE SHOOTING Problem What to check • Unit does not start Make sure the dehumidifier’s plug is pushed completely into the socket outlet. • Check the house fuse/circuit breaker box. • Dehumidifier has reached its preset level or drawer is full. •...
GUARANTEE AND CUSTOMER SERVICES At Russell Hobbs, we take all our customer feedback seriously. Feel free to contact our Product Care Team, on 0345 209 7461 who will be more than happy to assist you. This product is guaranteed for 12 months from the date of the original purchase.
SPARE PARTS To check the availability of the following spare parts, simply contact our friendly Customer Services team using the details provided at the bottom of this page. Air Filter Drain Hose Bung For Customer Services & Spare Parts please call 0345 209 7461 Or visit us at https://mda.russellhobbs.com Page 20...
CONNECTION TO THE MAINS SUPPLY This appliance is designed to operate from a mains supply of 220-240V~ 50Hz. Check that the voltage marked on the product corresponds with your supply voltage. How to change the fuse 1. Slot the end of a screwdriver into the recess in the fuse holder of the plug.
Specification RHDH2002 Model 220 – 240V 50Hz Voltage 440W Power Input 20L per day (DB 30 C RH = 80%) Moisture Removal R290/75g Refrigerant 24.5cm 35cm 51cm Overall Size (D x W x H) C - 35 Operating Temperature 15Kg...
Page 24
For Customer Services & Spare Parts please call 0345 209 7461 Or visit us at https://mda.russellhobbs.com Revision 1 Model: RHDH2002 Made by G2S Ltd under license. G2S Limited, Wigan, WN2 4AY This symbol is known as the 'Crossed-out wheelie bin Symbol'.