Camille Bauer SIRAX MT7000 Operating Manual page 28

Ac/dc current and voltage converter
Table of Contents

Advertisement

Available languages

Available languages

40016
Sec. for max RMS
40017
Sec. for min RMS
40018
Sec. for mean DC
40019
Sec. for max DC
40020
Sec. for min DC
40021
Sec. for mean AC
40022
Sec. for max AC
40023
Sec. for min AC
40024
Alarm Register Start
Address
40025
I Start
40027
Out Start
40029
I Stop
40031
Out Stop
40033
Steinhart Hart A
40035
Steinhart Hart B
40037
Steinhart Hart C
40039
Alarm Trip Value
40041
Alarm Hysteresis
40147
Status
40148
V I Out
40149
I RMS
10151
I DC
40153
I AC
40155
Frequency
40157
Crest Factor
40159
THD
40161
I 0 RMS
40163
I 1 RMS
40165
I 2 RMS
40167
I 3 RMS
PM 1001939 000 00
Seconds 1..30 for MAX RMS value. If the register is 0,
then the absolute MAX RMS is given
Seconds 1..30 for min RMS value. If the register is 0,
then the absolute min RMS is given
Register in seconds (0..30) for DC average
Seconds 1..30 for MAX DC value. If the register is 0,
then the absolute MAX DC is given
Seconds 1..30 for min DC value. If the register is 0,
then the absolute min DC is given
Register in seconds (0..30) for AC average
Seconds 1..30 for MAX AC value. If the register is 0,
then the absolute MAX AC is given
Seconds 1..30 for min AC value. If the register is 0,
then the absolute min AC is given
Float value Starting address for alarm (40149 I RMS,
40151 I DC, 40153 I AC, ecc)
Current (in A)/temperature (in °C) (see Flag Measure-
ment) which corresponds to Out start
Output value (in mV o in uA) of the chosen output
corresponding to I start
Current (in A)/temperature (in °C) (see Flag Measure-
ment) which corresponds to Out stop
Output value (in mV o in μA) of the chosen output
corresponding to I stop
Coeff Steinhart-Hart A
Coeff Steinhart-Hart B
Coeff Steinhart-Hart C
Alarm Threshold
Alarm Hysteresis
Bit 0: flash settings error
Bit 1: flash calibration error
Bit 2: Current Over Range; Bit 3: Current Under Range
Bit 4: don't care
Bit 5: RTD Open or broken
Bit 6: Current Zero crossing detecting
Bit 7: Switch open
Bit 8: RTD third wire error (Resistance > 20 Ω)
Bit 9: RTD out of the range (-200...+600°C)
Bit 10: Ah storing error
Bit 11: Analog Output over range
Bit 12: don't care
Bit 13: Alarm detection
Bit 14: Analog Output under range
Bit 15: don't care
Voltage or current output (in mV or mA)
RMS value (A)
DC value (A)
AC value (A)
Frequency (Hz)
Crest Factor
Total Harmonic Distortion
DC Harmonische
1. Harmonic
2. Harmonic
3. Harmonic
AC/DC Current and Voltage Converter SIRAX MT7000/MT7050
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Unsigned short
R/W
Float (LSW first)
R/W
Unsigned short
R/W
Float (LSW first)
R/W
Unsigned short
R/W
Float (LSW first)
R/W
Float (LSW first)
R/W
Float (LSW first)
R/W
Float (LSW first)
R/W
Float (LSW first)
R/W
Unsigned short
R
signed short
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
Float (LSW first)
R
0
0
0
0
0
0
0
0
40149
0
4000
5
20000
0
0
0
0
1
0
28/32