Onyx -1722 Manual

Medical station. high brightness slim medical panel pc

Advertisement

Quick Links

M e d i c a l S t a t i o n
O N Y X - 1 7 2 2 / 1 9 2 2
ONYX-1722/1922
®
TM
17"/19" Intel
Core
2 Duo
Processor
High Brightness
Slim Medical Panel PC
st
ONYX-1722/ 1922 Manual 1
Ed
January 2010

Advertisement

Table of Contents
loading

Summary of Contents for Onyx ONYX-1722

  • Page 1 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 ONYX-1722/1922 ® 17”/19” Intel Core 2 Duo Processor High Brightness Slim Medical Panel PC ONYX-1722/ 1922 Manual 1 January 2010...
  • Page 2 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Copyright Notice This document is copyrighted, 2010. All rights are reserved. The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice.
  • Page 3 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Acknowledgments ® ® Intel , Core 2 Duo are registered trademarks of Intel Corporation.
  • Page 4 O N Y X - 1 7 2 2 / 1 9 2 2 Packing List Before you begin installing your Medical Station, please make sure that the following items have been shipped: ONYX-1722 or ONYX-1922 Medical Station HDD screws Utility CD-ROM Contains User’s Manual (in PDF format), Drivers and...
  • Page 5 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Safety & Warranty 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3.
  • Page 6 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 14. If any of the following situations arises, get the equipment checked by service personnel: a.
  • Page 7 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Classification 1. Degree of production against electric shock: not classified 2. Degree of protection against the ingress of water: IPX0 3.
  • Page 8 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received...
  • Page 9 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 UL Module Description Onyx-1722/1922 AC modules are developed to suitable for the Classification Mark requirement...
  • Page 10 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Safety Symbol Description The following safety symbols are the further explanations for your reference.
  • Page 11 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Below Table for China RoHS Requirements 产品中有毒有害物质或元素名称及含量 AAEON Panel PC/ Workstation 有毒有害物质或元素 部件名称...
  • Page 12: Table Of Contents

    1.4 Dimension ..............1-8 Chapter 2 Hardware Installation 2.1 Safety Precautions ............ 2-2 2.2 A Quick Tour of the ONYX-1722/1922...... 2-3 2.3 Removing the rear maintenance cover ..... 2-5 2.4 2.5” Hard Disk Drive (HDD) Installation ....2-5 Chapter 3 Award BIOS Setup 3.1 System Test and Initialization .
  • Page 13 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 B.2 Memory Address Map..........B-2 B.3 IRQ Mapping Chart ..........B-3 B.4 DMA Channel Assignments........B-3 Appendix C Miscellanea C.1 General Cleaning Tips ..........
  • Page 14: Chapter 1 General Information

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Chapter General Information Chapter 1 General Information...
  • Page 15: Introduction

    The ONYX-1722/1922 includes all the features of a powerful computer into a slim and attractive chassis. Both of the ONYX-1722 has 380 nits and ONYX-1922 has 300 nits TFT displays with 1280 x 1024 resolution, and with 17” and 19” LCD respectively. Integrating with high brightness LCD is easier to analyze DICOM images.
  • Page 16: Features

    1000 : 1 Contrast Wide View Angle For X-Ray Film (ONYX-1722) 2000 : 1 Contrast Wide View Angle For X-Ray Film (ONYX-1922) 380 Nits High Brightness For X-Ray Film (ONYX-1722) 300 Nits High Brightness For X-Ray Film (ONYX-1922) ® Intel Core™...
  • Page 17: Specification

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 1.3 Specification Hardware Specifications ONYX-1722: 17” SXGA color TFT LCD Display ONYX-1922: 19” SXGA color TFT LCD System 200-pin DDRII SODIMM x 1, Max.
  • Page 18 White Mounting / Holder VESA 75/100mm Construction 3mm ABS + PC TYPE Plastic housing ONYX-1722: 15.1” x 13.3” x 2.8” Dimension (383mm x 338mm x 70mm) (W x H x D) ONYX-1922: 17.4” x 14.9” x 2.8” (442mm x 379mm x 70mm) Carton Dimension 23.8”...
  • Page 19 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Power Supply Specifications Power Requirement DC 9~30V 100 ~ 240V AC @ 47~ 63Hz, 1.4 ~0.6A Input Voltage 24V, 5A, 120W Max.
  • Page 20: Dimension

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 1.4 Dimension ONYX-1722 Unit: mm Unit: mm ONYX-1922 Chapter 1 General Information...
  • Page 21: Chapter 2 Hardware Installation

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Chapter Hardware Installation Chapter 2 Hardware Installation...
  • Page 22: Safety Precautions

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 2.1 Safety Precautions Always completely disconnect the power cord from your board whenever you are working on it.
  • Page 23: A Quick Tour Of The Onyx-1722/1922

    O N Y X - 1 7 2 2 / 1 9 2 2 2.2 A Quick Tour of the ONYX-1722/1922 Before you start to set up the ONYX-1722/1922, take a moment to become familiar with the locations and purposes of the controls, drives, connections and ports, which are illustrated in the figures below.
  • Page 24 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Figure 2.2: Rear view of the Medical Station Chapter 2 Hardware Installation...
  • Page 25: Removing The Rear Maintenance Cover

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 2.3 Removing the rear maintenance cover Pull USB cover; Unscrew the attachment screws used to hold the rear maintenance cover and remove rear cover.
  • Page 26 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 3. Assemble 2.5”HDD into disk module. 4. Connect HDD cable to 2.5” HDD connector Chapter 2 Hardware Installation...
  • Page 27: Chapter 3 Award Bios Setup

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Chapter Award BIOS Setup Chapter 3 Award BIOS Setup...
  • Page 28 The CMOS memory has lost power and the configuration information has been erased. The ONYX-1722/1922 CMOS memory has an integral lithium battery backup for data retention. However, you will need to replace the complete unit when it finally runs down.
  • Page 29 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 3.2 Award BIOS Setup Awards BIOS ROM has a built-in Setup program that allows users to modify the basic system configuration.
  • Page 30 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 PC Health Status This menu shows you the status of PC. Frequency/Voltage Control This menu shows you the display of frequency/Voltage Control.
  • Page 31: Chapter 4 Driver Installation

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Chapter Driver Installation Chapter 4 Driver Installation...
  • Page 32 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 The ONYX-1722/1922 comes with an AutoRun CD-ROM that contains all drivers and utilities that can help you to install the driver automatically.
  • Page 33 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 4.1 Installation: Insert the ONYX-1722/1922 CD-ROM into the CD-ROM drive. And install the drivers from Step 1 to Step 5 in order. ®...
  • Page 34 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 double click on the setup.exe Follow the instructions that the window shows The system will help you install the driver automatically Step 5 –...
  • Page 35: Appendix A Programming The Watchdog Timer

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Appendix Programming the Watchdog Timer Appendix A Programming the Watchdog Timer A-...
  • Page 36: Programming

    O N Y X - 1 7 2 2 / 1 9 2 2 A.1 Programming ONYX-1722/1922 utilizes ITE 8712 chipset as its watchdog timer controller. Below are the procedures to complete its configuration and the AAEON intial watchdog timer program is also attached based on which you can develop customized program to fit your application.
  • Page 37 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 (1) Enter the MB PnP Mode To enter the MB PnP Mode, four special I/O write operations are to be performed during Wait for Key state.
  • Page 38 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 WatchDog Timer Control Register (Index=71h, Default=00h) WatchDog Timer Configuration Register (Index=72h, Default=0 WatchDog Timer Time-out Value Register (Index=73h, Default=00h) Appendix A Programming the Watchdog Timer A-...
  • Page 39: Ite8712 Watchdog Timer Initial Program

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 A.2 ITE8712 Watchdog Timer Initial Program .MODEL SMALL .CODE Main: CALL Enter_Configuration_mode CALL Check_Chip mov cl, 7 call Set_Logic_Device...
  • Page 40 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 ; game port enable mov cl, 9 call Set_Logic_Device Initial_OK: CALL Exit_Configuration_mode MOV AH,4Ch INT 21h Enter_Configuration_Mode PROC NEAR...
  • Page 41 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Exit_Configuration_Mode ENDP Check_Chip PROC NEAR MOV AL,20h CALL Read_Configuration_Data CMP AL,87h JNE Not_Initial MOV AL,21h CALL Read_Configuration_Data CMP AL,12h...
  • Page 42 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 MOV DX,WORD PTR CS:[Cfg_Port+06h] IN AL,DX Read_Configuration_Data ENDP Write_Configuration_Data PROC NEAR MOV DX,WORD PTR CS:[Cfg_Port+04h] OUT DX,AL XCHG AL,AH MOV DX,WORD PTR CS:[Cfg_Port+06h]...
  • Page 43 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Set_Logic_Device proc near push ax push cx xchg al,cl mov cl,07h call Superio_Set_Reg pop cx pop ax Set_Logic_Device endp...
  • Page 44: Appendix B I/O Information

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 Appendix I/O Information Appendix B I/O Information...
  • Page 45: I/O Address Map

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 B.1 I/O Address Map Address Description User Address 000-01F DMA Controller #1 000-000F 020-03F Interrupt Controller #1, Master...
  • Page 46: Irq Mapping Chart

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 B.3 IRQ Mapping Chart IRQ0 System Timer IRQ8 System CMOS / Real time clock IRQ1 Keyboard IRQ9...
  • Page 47: Appendix C Miscellanea

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 ppendix Miscellanea Appendix C Miscellanea C-...
  • Page 48: General Cleaning Tips

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 C.1 General Cleaning Tips You may need the following precautions before you begin to clean the computer.
  • Page 49: Cleaning Tools

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 C.2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals.
  • Page 50 M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 • Cotton swabs - Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard, mouse, and other locations.
  • Page 51: Scrap Computer Recycling

    M e d i c a l S t a t i o n O N Y X - 1 7 2 2 / 1 9 2 2 C.3 Scrap Computer Recycling If the computer equipments need the maintenance or are beyond repair, we strongly recommended that you should inform us as soon as possible for the suitable solution.