Page 1
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 ONYX-1731 17”” Intel ® Celeron J1900 Quad Core Processor Slim Medical Panel PC ONYX-1731 Manual Jun., 2016...
ONYX, assumes no liabilities resulting from errors or omissions in this document, or from the use of the information contained herein. ONYX reserves the right to make changes in the product design without notice to its users.
Page 3
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Acknowledgments ® ® Intel Celeron is a registered trademark of Intel Corporation. ® ® Microsoft Windows is a registered trademark of Microsoft Corporation.
O N Y X - 1 7 3 1 Packing List Before you begin installing your Slim Medical Panel PC, please make sure that the following items have been shipped: ONYX-1731 Slim Medical Panel PC VESA Screws (M4 x 0.7 x 12mm) ...
Page 5
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Email: usasales@onyx-healthcare.com Onyx Healthcare EUROPE B.V. Primulalaan 42, 5582 GL Waalre, Netherlands Tel : +31-(0)499-745600 Email: eusales@onyx-healthcare.com Onyx Healthcare (Shanghai) INC.
Page 6
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Safety & Warranty 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Do not use liquid or spray detergents for cleaning.
Page 7
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 service personnel should open the equipment. 14. If any of the following situations arises, get the equipment checked by service personnel: a.
Page 8
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 modifier cet équipement sans l'autorisation du fabricant) Caution: It may cause the danger of explosion if battery is incorrectly replaced.
Page 9
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Classification 1. Degree of production against electric shock: Not classified. 2. Degree of protection against the ingress of water: IPX0 3.
Page 10
(1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. UL Module Description Onyx-1731 AC modules are developed to suitable for the Classification Mark requirement...
Page 11
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Safety Symbol Description The following safety symbols are the further explanations for your reference. Medical equipment with respect to electric shock, fire and mechanical hazards only in accordance with ANSI/AAMI ES 60601-1: 2005 AND CAN/CSA-C22.2 No.
Page 12
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Below Table for China RoHS Requirements 產品中有毒有害物質或元素名稱及含量 ONYX Panel PC/ Workstation 有毒有害物質或元素 部件名稱 鉛 汞 鎘 六價鉻 多溴聯苯 多溴二苯醚...
The ONYX-1731 includes all the features of a powerful computer into a slim and attractive chassis. ONYX-1731 has 350 nits TFT displays with 1280 x 1024 resolution. It supports 2.5” Hard Disk Drive storage and one Mini Card slot for WLAN expansion.
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 1.2 Features 17” SXGA TFT LCD Display Easy To Use, Compact, Simple Design Fanless, Zero Noise 1000 : 1 Contrast Wide View Angle ...
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 1.3 Specification Hardware Specifications 17” SXGA TFT LCD Display ® Intel Celeron J1900 Quad Core Processor System 204-pin DDR3 SODIMM x 2, Max. 8GB Memory Storage Drive 2.5”...
Page 18
1000 : 1 Brightness Control Back Light Life Time 30,000 Hrs Note: All ONYX's LCD products are manufactured with High precision technology. However, there are a small number of defective pixels in all LCD panels that are not able to change color.
Page 19
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Power Supply Specifications Adapter ATM065-P120 Model Input Voltage 100-240V AC, 2-1A @ 50-60 Hz Output Voltage 12V, 5A, 60W max. Environmental Specifications 10˚C to 40˚C (50˚F ~104˚F) Operating Temperature...
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 2.1 Safety Precautions Always completely disconnect the power cord from your board whenever you are working on it. Do not make connections while the power is on, because a sudden rush of power can damage sensitive electronic components.
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 2.2 Quick Tour of ONYX-1731 There are 5 control buttons in the front side of ONYX-1731. Please refer to table 2.1 for the function of each button. Control Buttons Picture 2.1: Front View of ONYX-1731...
Page 24
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Control Button Function Power On/Off Increase LCD brightness Decrease LCD brightness Increase speaker volume Hardware volume control - does not associate with Windows volume bar Decrease speaker volume Hardware volume control - does not associate with Windows volume bar Table 2.1: Functions of Control Buttons...
Page 25
The sunken I/O section is at the bottom, as shown in Picture 2.2. VGA out Isolated Gigabit LAN x2 Equipotential Terminal DC Power Input Line-out / Mic USB 2.0 x 4 Isolated RS-232 x 1 Picture 2.2: Bottom View of ONYX-1731 Chapter3 Driver Installation 3-4...
O N Y X - 1 7 3 1 2.3 Mounting with VESA Holes ONYX-1731 can be mounted with 75mm x 75mm or 100mm x 100mm VESA holes in the rear cover by wall-mount or desktop stand. Please use M4 x 0.7 x 12mm screws.
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Chapter Driver Installation Chapter3 Driver Installation 3-6...
Page 28
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 There are several installation ways depending on the driver package under different Operating Systems. Please follow the sequence below to install the drivers: For Windows 7/8.1: Step 1 –...
Disinfectant Germicide, Caviwipes, Dispatch Disinfectant Cleaner CLH69101, Puregreen 24 Disinfectant, can be used with ONYX-1731. Use of any other disinfectants will void the warranty. These cleaning disinfectants should be applied with a cloth or wipe, not sprayed directly on the computer.
Page 31
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 thoroughly dry the Onyx-1731 with a lint-free cloth. Note: We strongly recommend that you should shut down the system and remove the power cord before cleaning ONYX-1731.
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 A.2 Cleaning Tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals.
Page 33
Sl im M e di c a l Pa ne l PC O N Y X - 1 7 3 1 Cotton swabs - Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard, mouse, and other locations.
For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.onyx-healthcare.com.tw/Contact.php Note: Follow the national requirements to dispose unit Appendix A Miscellanea A-6...