Vaillant ecoTEC plus VU GB 5-5 Series Installation And Maintenance Instructions Manual page 56

Table of Contents

Advertisement

Appendix
Air/flue gas connection
NOx class
NOx emissions
CO emissions
CO₂ content min. volume
CO₂ content max. volume
Unit dimensions, width
Unit dimensions, height
Unit dimensions, depth
Approx. net weight without pump group
Technical data – Electrical
Electrical connection
Built-in fuse (slow-blow)
Min. electrical power consumption
Max. electrical power consumption
Standby electrical power consumption
IP rating
Test symbol/registration no.
56
806 (VU GB 806/5‑5)
1006 (VU GB 1006/5‑5)
110/160 mm
110/160 mm
6
6
≤ 40 mg/kW⋅h
≤ 40 mg/kW⋅h
≤ 30 mg/kW⋅h
≤ 30 mg/kW⋅h
8.8 vol%
9.0 vol%
9.0 vol%
9.0 vol%
480 mm
480 mm
960 mm
960 mm
603 mm
603 mm
68 kg
86 kg
806 (VU GB 806/5‑5)
1006 (VU GB 1006/5‑5)
230 V/50 Hz
230 V/50 Hz
4 A
4 A
25 W
18 W
122 W
160 W
< 2 W
< 2 W
IP X4 D
IP X4 D
CE‑ 0085CM0415
CE‑ 0085CM0415
Installation and maintenance instructions ecoTEC plus 0020134823_07
1206 (VU GB 1206/5‑5)
110/160 mm
6
≤ 40 mg/kW⋅h
≤ 30 mg/kW⋅h
9.0 vol%
9.0 vol%
480 mm
960 mm
603 mm
90 kg
1206 (VU GB 1206/5‑5)
230 V/50 Hz
4 A
18 W
160 W
< 2 W
IP X4 D
CE‑ 0085CM0415