1
Genius Plus
Installation Instructions
Double Linear
Imaging Technology
PIR Sensor
4
MOUNTING LOCATION
Choose a location most likely to intercept an
intruder. See the detection patterns in Fig. 5.
The twin dual element high quality sensors
detect motion across the beam field; they are
slightly less sensitive to motion towards the
detector.
While the GENIUS PLUS is capable of detecting
intrusions under exceedingly difficult conditions,
it is recommended to avoid the following
locations:
•
Areas where sunlight may shine
directly onto the PIR (lens).
•
Facing surfaces that may change
temperature extremely rapidly.
•
Areas with extreme airflows.
NOTE: Recommended installation
height is at 2.4m (7.9ft).
7
The circular and rectangular indentations at
the bottom base are the knockout hole for wire
entry. You may also use mounting holes that
are not in use for running the wiring into the
detector.
To close the front cover, insert the two small
prongs along its upper edge into their
corresponding slots in the upper edge of the
base. Insert the larger prong at the bottom of
the front housing into the slot at the bottom of
the base by exerting slight pressure on the
prong. The front cover should now fit snugly
into the base.
For detector installation it is
recommended to use set of
plastic anchors supplied with
the detector.
Caution: using different or
bigger screws can damage the
internal electronic board.
2
GENERAL DESCRIPTION
This Double Quad Element PIR detector is
based on the latest "ASIC" (Application Specific
Integrated Chip) and SMD technologies.
The Genius Plus monitors the environment by
analyzing the conditions and adapts to it
constantly. If conditions change, the GENIUS
PLUS adapts it maintaining sensitivity levels and
detection capability.
By using Double Quad Optic Systems with a
diagonally opposed configuration (phase shift
discrimination), the GENIUS PLUS is able to
achieve a three dimensional thermal image of
the protected area. It stores this image and
refers to it determine intrusions.
During the standby mode (no LED indications)
the GENIUS PLUS constantly monitors the
protected area, updating and reconfiguring itself
as conditions change
.
5
FIG. 1 – REMOVING THE FRONT COVER
8
FIG. 2 - OPTIONAL HOLES
The plastic base include different types of
knockdown holes:
A. Wire access
B
holes
B
B. Use for flat
C
C
wall mounting
C. Corner
mounting - use all
4 holes.
Seal the wiring
C
C
and other holes
B
applied to the
B
PIR case.
A
3
GENIUS PLUS FEATURES
•
Double Quad Linear Imaging
Technology for sharp analysis
of
body
dimensions
differentiation
background and animals.
•
Immunity to animals up to 5kg
(11 lbs).
•
High RF and EM Immunity.
•
Environmental immunity.
•
15m (49.2 ft) Detection Range
with Wide Angle Lens
•
Temperature compensation.
•
Compact
Design
Residential Installation
•
Variable
pulse
adjustment.
•
Sensitivity adjustment.
•
Height installation calibrations
free from 1.8m (5.9 ft) to 2.7m
(8.9 ft).
6
MOUNTING THE DETECTOR
A variety of mounting positions is possible with
the standard GENIUS PLUS housing.
1.
Open the front cover by pushing with
screwdriver the holding pin at the
middle of its lower surface and lifting
upwards.
2.
Snap out the detector PCB.
3.
The Genius Plus housing can be
mounted in a variety of ways. The
circular indentations in the housing
indicate mounting holes to be punched
out in accordance with the desired
mounting position:
4.
For surface mounting punch out the 4
indentations marked " B " (see Fig. 2).
5.
For Corner mounting gives 45° angles
on either the right or the left side. Punch
out the indentations marked " C " (see
Fig. 2)
9
FIG. 3 -
TERMINAL BLOCK CONNECTIONS
12VDC
TAMP RELAY
-
+
NC
NC
1
2
3
4
5
Terminal 1 - Marked " - " (-12V)
Connect to –12V e control panel.
Terminal 2 - Marked " + " (+12V)
Connect to a positive Voltage output of 8.2 -16Vdc
source (usually from the alarm control unit)
Terminals 3 & 4 - Marked " TAMPER "
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will be
sent to the control unit.
Terminals 5 & 6 - Marked " RELAY "
These are the detector relay contacts output.
Connect to a normally closed zone in the control
panel.
and
from
for
width