EM TEST AutoWave Manual For Operation page 17

Portable solution to simulate and measure battery supply voltage variation
Table of Contents

Advertisement

EM TEST
Setup 3:
example with:
Rack 1
RDS 200
RDS 200
RDS 200
AutoWave
PFS 200N
VDS 200N
Rack 2
LD 200N
UCS 200N
Manual for Operation
This configuration is suitable for testing Ford AC CI-230 tests with four waves at the
same time. The figure shows the output for:
- General tests at UCS output
- Dips and Drops at PFS 200
- Ford AC CI-230 at RDS and VDS outputs
Note : The default connection between the two racks is
Test Supply Out VDS – Test Supply IN PFS.
Dips and Drops are available on UCS 200 output, when the connection
Test Supply out PFS is used. The disadvantage is the additional voltage drop
inside the UCS 200.
Supply connections from VDS200Nx to PFS200N can be wired inside the rack.
Automotive rack for with 4 DC output for Ford AC CI-230 test
V 5.9.1
AutoWave