4 Visualization
4.9.3

Batch Control with Barcode Reader

Preconditions
Activate
H
batch
Show batch
report
42
If a barcode reader is connected to the interface "RS232 for barcode reader"
(connector 2) or "RS232/RS485" (connector 7), then the batch start, batch
stop, and input of batch texts in a current batch report, can be controlled by
the barcode reader. The bar codes that are used all correspond to the type
"Code39".
• The interface must be configured for bar code operation.
Example:
Configuration
Interface
Protocol = bar code.
• The batch start (= batch stop) must be configured.
Example for batch start/stop:
Configuration
Batch/plant
bar code.
• Every line that is to be set by the bar code must be configured.
Example for plant 1, line 1 (program name):
Configuration
Batch/plant
column = bar code.
Before entering commands through a barcode reader, the
corresponding batch/plant 1 — 3 must be prepared by scanning in
"BATCH1 — 3" for the bar code commands, regardless of whether
or not they are automatically displayed.
If one of the visualizations is active, and nothing is being entered or edited at
the moment, then the current batch report can be inserted via the barcode
reader. The precondition is that the batch is active and the parameter is set to
Configuration
Screen
Activate and display (if required) batch report for batch (plant) 1:
Activate and display (if required) batch report for batch (plant) 2:
RS232 for barcode reader
Batch (Plant) 1
Batch (Plant) 1
Bar code -> current batch = Yes.
General
General
Batch start =
Line 1
Content of right