Safety Warnings

This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring
regulations. It should be installed in accordance with local building regulations and is for domestic use only.
Before commencing installation of your light fitting always switch off the mains supply and remove the appropriate
fuse or switch off the appropriate circuit breaker.
This is a Class I product, and must be Earthed.
the fitting.
Run supply wire from a 5-amp electrical supply protected by an RCD using double insulated 3-core cable of type
H05RN-F 1.0mm2 (not supplied) to selected site, ensuring it is adequately protected through the full length of the
cable run, it must come out of the flat surface of the wall or steps in line with the entry to the fitting.
Except where installed in a conduit or duct which provides equivalent protection against mechanical damage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a
protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable covers or
a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables, conduits and ducts
shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable disturbance of the ground.
Never fit bulbs of a higher wattage than those specified on the label, as these may cause overheating and damage
the fitting.
This product has special protection against the ingress of water, and is rated IP44.
If any modification is made it will invalidate the warranty and may render the product unsafe.

Care Information

Allow 10 minutes to cool before replacing, adjusting or cleaning.
In normal circumstances, stainless steel is very resistant to corrosion. It does however require maintenance to
preserve the high quality appearance. Wash the product with warm soapy water, removing all surface deposits.
Rinse with clear water and with a soft cloth, wipe dry. In some cases, surface corrosion may arise after installation.
This is normally caused by tiny iron particles left behind after the polishing process when finishing. Wash and dry as
detailed above. Then with a soft cloth soaked with a protective oil, wipe all over.
However if the product is subject to extreme environmental conditions such as marine locations, industrial pollution
and acid rain these maintenance procedures should be carried out around four times a year. For severe corrosion,
non-abrasive cream cleaners or proprietary stainless steel cleaners should be used to remove the corrosion. Wash
and dry as detailed above. Then with a soft cloth soaked with a protective oil, wipe all over.

Assembly/ User Instructions

Please read these instructions carefully before fitting and retain for reference. Check the packaging and make sure
that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly. Ensure that
the product is fully assembled as illustrated before use.
The Light pack contains:
Light fitting.
Terminal connection block(s).
Fixing pack.
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
Endon Lighting, LS9 0SE
Dexter PIR Outdoor Wall light Fitting
INSTRUCTION MANUAL
Before you start
The terminal blocks are supplied according to requirements of
The following tools may be required:
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
74702-Dexter-WB 20180611

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dexter and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Endon Dexter

  • Page 1 Dexter PIR Outdoor Wall light Fitting INSTRUCTION MANUAL Safety Warnings • This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring regulations. It should be installed in accordance with local building regulations and is for domestic use only.
  • Page 2 7. Fit the bulb (H - not supplied). NOTE: Never fit bulbs of a higher wattage than those specified on the label as these may cause overheating and damage the fitting. 8. Screw the glass shade (I) onto the lampholder to secure in place. 9. Turn on the power and test. 10. This product fitted with a PIR sensor (J). Please see overleaf for adjustment details. Endon Lighting, LS9 0SE 74702-Dexter-WB 20180611...
  • Page 3 • The PIR sensor can be adjusted, allowing the detection distance to be altered to suit the location. The detection is set at 90 degrees and has a maximum range of 10 metres. The duration that the lamp stays on can also be altered from (10±5) seconds up to (4±1) minutes . Use a small screwdriver to adjust the ‘TIME’ and ‘SENS’ screws. When adjusting the sensitivity (detection distance) in daylight it will be necessary to cover the sensor to simulate night time. Endon Lighting, LS9 0SE 74702-Dexter-WB 20180611...

Table of Contents