EAS EMH750CGB Manual page 50

Table of Contents

Advertisement

Available languages

Available languages

trouble shooting
Repairs should be performed by a licensed technician only. Improper repair may result in considerable
danger to you and others.
■ However, some minor problems can be resolved as follows :
Problem
Not ignited
Badly ignited
Noise made when
combusted and ignited
Flame goes out when
in use.
Yellow Flame
Unstable Flame
Gas Smell
centre.
Probable cause
No Spark.
The burner lid is badly assembled.
The gas supply is closed.
The gas supply is not completely
open.
The burner lid is badly assembled.
The ignition plug is contaminated
with alien substance.
The burners are wet.
The holes in the flame spreader are
clogged.
The burner lid is badly assembled.
The flame supervision device is
contaminated with alien substance.
Product being cooked has boiled
over and extinguished the flame.
A strong draught may have blown
the flame out
.
The holes in the flame spreader are
clogged.
Different gas is used.
The burner lid is badly assembled.
Gas leakage
24
Solution
Check the electricity supply
Assemble the lid correctly.
Open the gas supply completely.
Open the gas supply completely.
Assemble the lid correctly.
Wipe alien substance with a dry
.
cloth
Dry the burners lids carefully.
Clean the flame spreader.
Assemble the burner lid
correctly.
Clean the flame supervision
device.
Turn off burner knob. Wait
minute
and reignite zone.
Please turn off zone and check
cooking area for draught such as
open windows. Wait
one minute
and reignite zone
Clean the flame spreader.
Check the gas used.
Assemble the burner lid
correctly.
Stop using the product and close
the middle valve.
Open the window to ventilate.
Contact our service centre by
using a phone outside.
.
one
V.2

Advertisement

Chapters

Table of Contents
loading

Related Products for EAS EMH750CGB

Table of Contents