conversion
gas
■ Take precautions on the operations and adjustments to
be carried out when converting from one gas to another.
■ All work must be carried out by a qualified technician.
■ Before you begin, turn off the gas and electricity supply
to the appliance.
1
Injector
2
Adjustme n n t of minimum l e e vel of the flam e e
■ Do not dismantle the tap shaft :
in the event of a malfunction, change the whole tap.
■ Before placing the burners back on the top place, make sure
that the injector is not blocked
■ A full operational test and a test for possible leakages must
be carried out after gas conversion (such as soapwater or gas
detector)
■After completing conversion
a qualified technician or installer has to mark "V" on the right
gas category to match with the setting in rating plate.
Remove the previous setting "V" mark.
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7 mm box spanner and replace it with
the stipulated injector for new gas supply.
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly tighten the
injector in place.
Tu u rn the taps down to minimum
R R emove the knob from the tap and place a small
Control handle
bladed screwdriver in the centre of the tap shaft.
The correct adjustment is obtained when the flame
Tap
has a length of about 3 - 4 mm.
Sealing ring
For butane propane gas, the adjusting screw
must be tightly screwed in.
Refit the control knob.
M
turning
does then remove the control knob and make further
adjustments to the gas flow, testing it again once the
adjustment has been made.
Repeat this process for each one of the gas taps.
/
ake sure that the flame does not go out by quickly
from maximum flow to minimum flow. If it
23