EUCHNER ESM-CB Operating Instructions Manual

Safety relay with io-link for emergency stop, safety door and light grid monitoring
Table of Contents

Advertisement

Quick Links

Operating Instructions
Safety Relay with IO-Link
EN
for emergency stop, safety door and light grid monitoring
ESM-CB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESM-CB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EUCHNER ESM-CB

  • Page 1 Operating Instructions Safety Relay with IO-Link for emergency stop, safety door and light grid monitoring ESM-CB...
  • Page 2: Table Of Contents

    Operating Instructions Safety Relay with IO-Link ESM-CB Contents About this document ..................... 4 1.1. Scope ............................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................5 Description of the safety function ................6 3.1.
  • Page 3 Operating Instructions Safety Relay with IO-Link ESM-CB Device diagnostics ....................21 13.1. Diagnostics via LED displays ......................21 13.1.1. General states .........................21 13.1.2. Error messages .......................22 IO-Link communication and diagnostic data ............23 14.1. Device description file ........................23 14.1.1. Overview of IODDs ......................23 14.1.2.
  • Page 4: About This Document

    Scope This document is valid for: Ì Safety Relay with IO-Link for emergency stop, safety door and light grid monitoring ESM-CB 1.2. Target group Design engineers and installation planners for safety devices on machines, as well as setup and servicing staff possessing special expertise in handling safety components.
  • Page 5: Correct Use

    Operating Instructions Safety Relay with IO-Link ESM-CB 2. Correct use The safety relay is used to monitor safety-related signaling devices and to control actuators. The safety circuit monitors two sensor circuits. Each sensor circuit can have one or two channels. When at least one sensor circuit is interrupted, the safety relay initiates the safe state.
  • Page 6: Description Of The Safety Function

    Operating Instructions Safety Relay with IO-Link ESM-CB 3. Description of the safety function 3.1. Monitoring of sensor circuits The safety circuit monitors two sensor circuits. Each sensor circuit can have one or two channels. The safety relay can be operated only if both sensor circuits are used. If only one sensor circuit is used, the second sensor circuit must be bridged.
  • Page 7: Exclusion Of Liability And Warranty

    Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. EUCHNER cannot provide any warranty in relation to the readability of the CD for the storage period required. For this reason you should archive a printed copy of the operating instructions.
  • Page 8: Function

    Operating Instructions Safety Relay with IO-Link ESM-CB 6. Function 6.1. IO-Link communication and functions The safety relay is an IO-Link device. Communication via IO-Link offers cyclical (process data) and acyclical (device data and events) data exchange. Important! The cyclical and acyclical data can be found in chapter 14. IO-Link communication and diagnostic data.
  • Page 9: Block Diagram

    Operating Instructions Safety Relay with IO-Link ESM-CB 6.2. Block diagram OSSD OSSD Safety ID/C Contacts Start Safety Inputs LOGIC IO-Link Slave Figure 1: Block diagram Power supply 24 V DC Power supply 0 V Supply input for S14 Supply output for S12 and S21 Sensor circuit S1 input (channel 1)
  • Page 10: Communication And Functions With Br Safety Switches

    Operating Instructions Safety Relay with IO-Link ESM-CB 6.3. Communication and functions with BR safety switches 6.3.1. Diagnostic data The ID/C connection of the safety relay allows the diagnostic line of a BR safety switch chain to be connected. The ID/C connection represents a non-safety-related communication channel between the safety relay and the safety switches.
  • Page 11: Mounting

    Operating Instructions Safety Relay with IO-Link ESM-CB 7. Mounting NOTICE Device damage due to improper installation or unsuitable ambient conditions. Ì The safety relay must be installed in a control cabinet protected against dust and moisture, with a minimum degree of protection of IP54. A snap-in element on the rear of the device is used for fastening to a mounting rail.
  • Page 12: Electrical Connection

    Operating Instructions Safety Relay with IO-Link ESM-CB 8. Electrical connection WARNING If there is a mistake, loss of the safety function due to incorrect connection. Ì Monitoring outputs must not be used as safety outputs. Ì Lay the connecting cables with protection to prevent the risk of short circuits.
  • Page 13: Terminal Assignment

    Operating Instructions Safety Relay with IO-Link ESM-CB 8.1. Terminal assignment Power supply 24 V DC A1 A2 S21 Power supply 0 V Supply input for S14 Supply output for S12 and S21 Sensor circuit S1 input (channel 1) Sensor circuit S1 input (channel 2) Input for start circuit STATE1 OSSD sensor circuit S2 input (channel 1), input for FO1A from BR series connection...
  • Page 14: Signaling Device Connection Variants

    Operating Instructions Safety Relay with IO-Link ESM-CB 8.2. Signaling device connection variants Important! The safety relay can be operated only if both sensor circuits are used. If only one sensor circuit is used, the second sensor circuit must be bridged.
  • Page 15: Start Circuit And Feedback Loop Connection Variants

    Operating Instructions Safety Relay with IO-Link ESM-CB 8.3. Start circuit and feedback loop connection variants WARNING Danger due to the machine restarting automatically Ì When the manual reset function is used with monitored starting, a short circuit between A2/S21/0 V can the cable of the start button can cause the machine to start up automatically. This applies in particular to safety functions with a high risk potential.
  • Page 16: Notes About

    Operating Instructions Safety Relay with IO-Link ESM-CB 8.4. Notes about Important! Ì For use and operation as per the requirements , a power supply with the feature “for use in class 2 circuits” must be used. Alternative solutions must comply with the following requirements: - Electrically isolated power supply unit with a max.
  • Page 17 Operating Instructions Safety Relay with IO-Link ESM-CB 24 V DC FI1A FI1B Safety Inputs Monitoring Safety Output Outputs OD/C FO1A FO1B FI1A FI1B Safety Inputs Monitoring Safety Output Outputs OD/C FO1A FO1B FI1A FI1B Safety Inputs Monitoring Safety Output Outputs...
  • Page 18: Setup

    Operating Instructions Safety Relay with IO-Link ESM-CB 10. Setup WARNING Ì In emergency stop applications, automatic machine startup can pose a severe danger to the oper- ator. - Prevent the machine from being started up again automatically by the higher-level control system.
  • Page 19: Calculating The Power Dissipation

    Operating Instructions Safety Relay with IO-Link ESM-CB 11. Calculating the power dissipation Important! The total power dissipation of the safety relay results from the input power dissipation and the contact power dissipation with equal or differing load currents. Input power dissipation  = U...
  • Page 20: Function Test

    Operating Instructions Safety Relay with IO-Link ESM-CB 12. Function test WARNING Loss of functional safety due to malfunction. Ì Proper function of the device can no longer be ensured if the function test is faulty. - Replace the device. 1. Switch on operating voltage.
  • Page 21: Device Diagnostics

    Important! Ì Plausibility errors are deleted when the power supply is switched off (power-down reset). Ì Please contact EUCHNER if an error or fault symptom that is not listed occurs. 13.1. Diagnostics via LED displays Important! Behavior of the IO-Link LED Ì...
  • Page 22: Error Messages

    Operating Instructions Safety Relay with IO-Link ESM-CB 13.1.2. Error messages LEDs Status State STATE 1 STATE 2 K1/K2 IO-Link green green green green green Internal error Module is not ready for operation. External error: The channel 1 sensor circuit was opened and Input error at S1 reactivated, e.g.
  • Page 23: Io-Link Communication And Diagnostic Data

    The valid device description files are available for download from the address www.euchner.com|service|download|software. You additionally have the option of downloading the device description file from the official IO-Link page ioddfinder.io-link.
  • Page 24: Process-Data Structure And Addressing

    Cyclical data (process data) Depending on the corresponding IODD, the device occupies 6/11/21/31 input process-data items and 1, 6, 11 or 16 output data items. 14.3.1. Input data Byte 0 (IO-Link diagnostic bits/status of ESM-CB) Description Value 0: Sensor circuit S1 inactive Bit 0...
  • Page 25: General Description Of The Process Data

    Please refer to the manual of the connected interlocking device or guard locking device to determine which bits are actually used. Not all switches support every bit. 14.3.3. Output data Byte 0 (IO-Link diagnostic bits/status of ESM-CB) Description Value 0: Deactivated (safety contacts blocked)
  • Page 26: Acyclical Data (Device Data And Events)

    Operating Instructions Safety Relay with IO-Link ESM-CB 14.4. Acyclical data (device data and events) 14.4.1. Writing and reading services Important! The manufacturer’s code for EUCHNER is 0x01. Index 100 – reading service: size of the input/output data areas Index Subindex Type Description...
  • Page 27 00. Example: 01 02 00 00 00 00 00 00 01 = User data length 02 = Request telegram to the ESM-CB (order number/serial number) Bytes 2 … 7: padded zeros Index 250 – writing service: IO-Link mode Index Subindex...
  • Page 28: Communication With Br Devices

    Operating Instructions Safety Relay with IO-Link ESM-CB 14.5. Communication with BR devices Note: The data is in Big Endian format. Transmission Reply Command Number of bytes Number of bytes Send order no. and serial no. 3 bytes for order no.
  • Page 29: Error Table For Br Devices

    Operating Instructions Safety Relay with IO-Link ESM-CB 14.6. Error table for BR devices Depending on the device type, not all error messages are required or supported. Error number Error designation Cause/remedy 0x01+A4:E25 Internal error All errors that prevent normal operation and over which the customer has no control.
  • Page 30: Technical Data

    Operating Instructions Safety Relay with IO-Link ESM-CB 15. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 15.1. Safety relay ESM-CB Approvals Ì Diagnostic data via IO-Link in combination with BR safety switches Ì...
  • Page 31 Operating Instructions Safety Relay with IO-Link ESM-CB Technical data for ESM-CB Hardware/firmware version HW/FW ≥ 00/100 The technical data and the safety characteristics are valid from the specified HW/FW version. Supply Name A1/A2 Operating voltage U 24 V DC -20 % / +25 % (fuse externally) Rated control supply current I Typ.
  • Page 32 Operating Instructions Safety Relay with IO-Link ESM-CB Digital inputs: sensor circuit S1 Number of inputs 2 (safety-related sensor inputs: S32, S34) Description of the input Input voltage range of “0” signal 0 V DC … 5 V DC Input current range of “0” signal 0 mA …...
  • Page 33 Operating Instructions Safety Relay with IO-Link ESM-CB General data Relay type Electromechanical relay with positively driven contacts according to IEC/EN 61810-3 (EN 50205) Nominal operating mode 100% duty cycle Degree of protection IP20 Minimum degree of protection of installation location IP54 Mounting method...
  • Page 34 Operating Instructions Safety Relay with IO-Link ESM-CB Safety engineering characteristics for IEC 61508 – low demand Device type Type A 3.76 x 10 Davg Proof-test interval 36 months Mission time 240 months Safety engineering characteristics according to EN ISO 13849 depending on the switching current at 24 V DC...
  • Page 35: Function And Time Diagrams

    Operating Instructions Safety Relay with IO-Link ESM-CB 15.2. Function and time diagrams 15.2.1. Time diagram for automatic start 15.2.2. Time diagram for manual, monitored start Continuous auto start Ì Permanently High signal at S21 Ì Start on falling edge at S21...
  • Page 36: Derating

    Operating Instructions Safety Relay with IO-Link ESM-CB 15.3. Derating 15.3.1. Vertical or horizontal installation orientation The derating curve is applicable under the following conditions: Ì Mounting on vertical or horizontal mounting rail Ì Devices mounted without intervening distance Ì At U up to max. 30 V DC...
  • Page 37: Ordering Information And Accessories

    16. Ordering information and accessories Tip! Suitable accessories, e.g. cables or assembly material, can be found at www.euchner.com. To order, enter the order number of your item in the search box and open the item view. Accessories that can be combined with the item are listed in “Accessories.”...
  • Page 38: Service

    Operating Instructions Safety Relay with IO-Link ESM-CB 18. Service If service support is required, please contact: EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Service telephone: +49 711 7597-500 E-mail: support@euchner.de Internet: www.euchner.com (Translation of the original operating instructions) 2522722-01-05/19...
  • Page 39: Declaration Of Conformity

    Operating Instructions Safety Relay with IO-Link ESM-CB 19. Declaration of conformity 2522722-01-05/19 (Translation of the original operating instructions)
  • Page 40 Edition: 2522722-01-05/19 Title: Operating Instructions Safety Relay with IO-Link ESM-CB (Translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 05/2019 Subject to technical modifications; no responsibility is accept- ed for the accuracy of this information.

Table of Contents