Chapter 4
No.
Name
1-11
Keep Time after STO-A
1-12
STO-A release mode
1-21
SS1-A Zero frequency
1-22
SS1-A monitoring method
1-23
SS1-A Active time
1-24
SS1-A Min ramp time
1-25
SS1-A Max ramp time
1-26
SS1-A Wait Time
1-31
SBC-A Time linkage
1-32
SBC-A Wait time after STO-A
1-33
SBC-A Wait time before STO-A
1-34
SBC-A frequency
1-35
SBC-A STO-A release wait time
1-36
SBC-A release level
1-41
SLS-A frequency limit CCW/FW
1-42
SLS-A frequency limit CW/RV
1-43
SLS-A time delay
1-51
SDI-A active mode
1-52
SDI-A time delay
1-61
SSM-A frequency CCW/FW
1-62
SSM-A frequency CW/RV
2-11
Keep Time after STO-B
2-12
STO-B release mode
2-21
SS1-B Zero frequency
2-22
SS1-B monitoring method
2-23
SS1-B Active time
2-24
SS1-B Min ramp time
2-25
SS1-B Max ramp time
2-26
SS1-B Wait Time
2-31
SBC-B Time linkage
2-32
SBC-B Wait time after STO-B
2-33
SBC-B Wait time before STO-B
2-34
SBC-B frequency
2-35
SBC-B STO-B release wait time
2-36
SBC-B release level
2-41
SLS-B frequency limit CCW/FW
2-42
SLS-B frequency limit CW/RV
2-43
SLS-B time delay
2-51
SDI-B active mode
2-52
SDI-B time delay
2-61
SSM-B frequency CCW/FW
2-62
SSM-B frequency CW/RV
Range
0.00 to 3600.00s
00:without release / 01:with safety signal /
02:with release signal
0.10 to 10.00Hz
00:Time /01: Frequency
0.00 to 3600.00s
0.00 to 3600.00s
0.00 to 3960.00s
0.00 to 600.00s
00: SBC after STO/01: SBC before STO/
02:SS1 then SBC after STO/03:SS1 then SBC before STO
0.00 to 3600.00s
0.00 to 10.00s
0.00 to 100.00Hz
0.00 to 10.00s
0.00 to 100.00%
0.00 to 590.00Hz
0.00 to 590.00Hz
0.00 to 3600.00s
00:CW(RV)-limit/01:CCW(FW)-limit
0.00 to 3600.00s
0.00 to 590.00Hz
0.00 to 590.00Hz
0.00 to 3600.00s
00:without release / 01:with safety signal /
02:with release signal
0.10 to 10.00Hz
00:Time /01: frequency
0.00 to 3600.00s
0.00 to 3600.00s
0.00 to 3960.00s
0.00 to 600.00s
00: SBC after STO/01: SBC before STO/
02:SS1 then SBC after STO/03:SS1 then SBC before STO
0.00 to 3600.00s
0.00 to 10.00s
0.00 to 100.00Hz
0.00 to 10.00s
0.00 to 100.00%
0.00 to 590.00Hz
0.00 to 590.00Hz
0.00 to 3600.00s
00:CW(RV)-limit/01:CCW(FW)-limit
0.00 to 3600.00s
0.00 to 590.00Hz
0.00 to 590.00Hz
4-13
Safety Function
Default
Memo
1.00
01
5.00
00
1.00
1.00
30.00
1.00
00
1.00
1.00
0.00
0.00
100.00
72.00
50.00
10.00
00
10.00
72.00
50.00
1.00
01
5.00
00
1.00
1.00
30.00
1.00
00
1.00
1.00
0.00
0.00
100.00
72.00
50.00
10.00
00
10.00
72.00
50.00