Hitachi SJ Series Safety Function Manual page 20

Functional safety option
Hide thumbs Also See for SJ Series:
Table of Contents

Advertisement

Chapter 4
4.4.4
Output terminal
Output signals of Safety function are redundant outputs of
terminal group -1 and terminal group -2.
When the Safety function is inactivated, voltage is applied
to each output and currents flow on each safety path.
When the Safety function is activated, voltage is removed
from each output and currents do not flow on each safety
path.
When the monitoring and completed signals are activated,
voltage is applied to each output and currents flow on each
path. When the monitoring and completed signals are
inactivated, voltage is removed from each output and
currents do not flow on each path.
The voltage source for output signals of safety function is
an externally prepared DC24V power supply. The external
power supply must be SELV or PELV DC24V power supply.
Please
connect
between
corresponding common for checking the path if the output
terminal is not used.
■Wiring
S12
S12
S11
S11
24V1 24V2
CMo1 CMo2
S13
S13
24V3 24V4
CMo3 CMo4
S3
S3
S2
S2
S1
S1
RLS
CME
P24E
STC
ST1
ST2
output
terminal
and
24V
4-6
■Selecting output terminal function
It can be set the output terminal function.
No.
Name
Related data
00:None / 01:STO-A monitoring /
Safety Function
02:STO-A completed / 03:SS1-A monitoring /
0-11
Select Output 1
04:SS1-A completed / 05:SBC-A control /
06:SLS-A monitoring / 07:SDI-A monitoring /
Safety Function
08:SSM-A monitoring / 11:STO-B monitoring /
0-12
Select Output 2
12:STO-B completed / 13:SS1-B monitoring /
14:SS1-B completed / 15:SBC-B control /
16:SLS-B monitoring / 17:SDI-B monitoring /
Safety Function
0-13
18:SSM-B monitoring / 21:Internal error /
Select Output 3
31:test pulse (only S13)
■NO/NC switching function
NO/NC state can be switched.
No.
Name
0-41
Output arrangement 1
0-42
Output arrangement 2
0-43
Output arrangement 3
■Setting output sensitivity
Signal level is completed after the output sensitivity time is
passed from switching the signal level.
No.
Name
0-71
Output 1 sensitivity
0-72
Output 2 sensitivity
0-73
Output 3 sensitivity
■Setting allowed gap time
Allowed gap time is set for delaying output of path 2.
No.
Name
0-91
Output 1 gap time
0-92
Output 2 gap time
0-93
Output 3 gap time
Safety Function
Related data
00:NC(path 1 and path 2) /
01:NC(path 1) and NO(path 2) /
01:NO(path 1 and path 2)
Related data
0.001 to 1.000s
Related data
0.001 to 1.000s

Advertisement

Table of Contents
loading

This manual is also suitable for:

P1P1-fs

Table of Contents