Table 13: Axial piston unit malfunction table
Malfunction
No or insufficient pressure
Possible cause
Insufficient air bleeding of the hydraulic system
Faulty mechanical drive (e.g. defective coupling) Contact machine/system manufacturer
Drive power too low
Insufficient suction conditions, e.g. insufficient
dimensioning of the suction line, viscosity of
the hydraulic fluid too high, suction height too
high, suction pressure too low, contaminants in
the suction line, suction filter too small, etc.
Hydraulic fluid not in optimum viscosity range
Insufficient boost pressure
Insufficient pilot pressure or control pressure
Malfunction of the control device or controller
of the axial piston unit
Control of the control device defective
Wear or mechanical damage to the
axial piston unit
Output unit defective
(e.g. hydraulic motor or cylinder)
Troubleshooting
Remedy
Fill axial piston unit, suction line for
the hydraulic pump and the reservoir
Completely air bleed axial piston unit
and hydraulic system
Check correct installation position
Contact machine/system manufacturer
Machine/system manufacturer: check
the system, e.g. optimize inlet conditions,
use suitable hydraulic fluid
Fill the suction line with hydraulic fluid
Remove contaminants from the suction line
Check the filter system and change the
filter as necessary
Machine/system manufacturer:
check temperature range and use
suitable hydraulic fluid
Check boost pressure
Contact Bosch Rexroth Service
Check pilot pressure or control pressure
Contact Bosch Rexroth Service
Contact Bosch Rexroth Service
Check control (contact machine/system
manufacturer or Bosch Rexroth Service)
Replace axial piston unit
Contact Bosch Rexroth Service
Contact machine/system manufacturer
RE 92003-01-B/12.2015, A4VG Series 32, Bosch Rexroth AG