Hardware Configuration; Power Board - gefran 556 Quick Start Manual

Timer, counter, frequency meter

Advertisement

Accessing the boards
To remove the electronic parts from the case, open the extraction clips.

Power board

To select the supply voltage 110/220V (24/48Vac; 120/240V):
110V (24/120V) - close two jumpers P and remove jumpers S;
220V (48/240V) - close two jumpers S and remove jumpers P;
24Vdc available on request (see order code).
CPU-inputs boards
Hardware protection of configuration.
- Configuration disabled: close jumper S9 and remove jumper S10.
- Configuration enabled: close jumper S10 and remove jumper S9.
The standard version is supplied with configuration enabled.
Digital logic input 1 "IN1"
Active when closed: close jumper S7B
Active when open: close jumper S7A
The standard version is supplied with IN1 active when closed.
Selecting hardware filter on inputs
You can insert 3 different low pass filters for each input by installing the appropriate jumpers.
IN1
Freq.
S5
S6
0=5kHz
Open
Open
1=1kHz
Closed*
Open*
2=100Hz
Open
Closed
*
Standard version
Setpoint variation can be disabled in any application by setting the software password to 1 (Pro function).
Programming the TIMER (Function Typ=0)
In normal operation, display A shows the real value of the active time. Setpoint values for Time 1 (and Time 2) are set with the raise/lower buttons. Time 1 is
changed immediately; Time 2 is selected with the F key. They are managed with the following inputs:
- IN1 START/STOP
- IN2 RESET
- IN3 HOLD or UP/DOWN (see configuration of IN3 functions).
If the function of IN3 is defined as UP/DOWN, it causes inversion of the current value of Time 1; Time 2 maintains its direction.
If the timer is configured to down (Fun=0), it loads the preset value and counts down toward zero; by closing IN3 (if configured to "active when closed"), you tempo-
rarily reverse the direction of time 1 to up until Full Scale is reached.
If the timer is configured to up (Fun=1), it starts from zero and counts to Set, closing IN3 (if configured to "active when closed") and temporarily reversing the
change in time 1 to down. The HOLD function freezes the display only: the timer function stays active.
Programming the COUNTER (function Typ=1)
In normal operation, display A shows the real value of the active count.
The setpoints for Count 1 Time 2/Count 2 are set by pressing the Raise/Lower buttons.
Time 1 is changed immediately, Select Time 2 / Count 2 with the F key.
The Counter is managed with the following inputs:
- IN1 CLOCK (max. frequency 5KHz)
- IN2 RESET
- IN3 HOLD or UP/DOWN (see configuration of IN3 functions).
A prescaler factor can be inserted on the clock: x2, / 2, / 10, / 100.
The displayed/set value can be expressed in engineering units by setting the MUL and DIV functions.
Example 1:
By setting MUL = 1 and DIV = 60, you reset the parameter so that the display shows:
no. real pulses • MOL
=---------------------------------
=
DIV
The setting corresponds to :
For example, if you set 1, you get:
i.e., with the counter configured up, 60 real pulses have to be counted before "1" is reached.
The count sequence displayed
0, 1, 2, .... etc., corresponds to a real count of 60 pulses
0, 60, 120, ..... etc.
80469C_MHW_556_02-2011_ENG
5 • HARDWARE CONFIGURATION
IN2
S3
S4
S1
Open
Open
Open
Closed
Open
Closed
Open*
Closed*
Open*
6 • PROGRAMMING
o. real pulses • 1
o. real pulses
----------------------------
=
-------------------------
60
Set value • DIV
------------------------------
MOL
1
60
------------ = 60
1
IN3
S2
Open
Open
Closed*
60
POWER BOARD
CPU BOARD
3