  • Page 1 KL34000 ooLant anageMent ySteM perating nStruCtionS 315 Garden Avenue • Holland, MI 49424 www.klineind.com • 1-800-824-KLINE (5546) • cservice@klineind.com...
  • Page 2: Hazard Avoidance

    DISCLAIMER: All information, images, and specifications contained in this manual are based on the latest information available at the time of publication. K-Line® reserves the right to make changes at any time without notifying any person or organization of such revisions or changes.
  • Page 3 The KL34000 Coolant Management System uses two unique adapters and stan- dard shop air to create regulated pressure that forces the coolant out of the entire system, allowing for a pressure test and any necessary repairs to be made.
  • Page 4 efore roCeeding A special male quick-connect fitting will be needed to replace the coolant drain petcock. Vehicles not built with this fitting are easily retrofitted. Refer to TMC RP353 or ISO 16028 to ensure that you have the proper fitting. Please ensure that this fitting is installed on the vehicle before using the tool.
  • Page 5 reSSure roCedure Set Tank Valve to the CLOSED po- sition. Turn the 3-Way Air Valve to DRAIN and monitor the Pressure Module until gauge stabilizes. Close 3-Way Air Valve. System is now pressurized with air. Take note of the gauge reading and Image 4: Step 1 check for pressure decay.
  • Page 6 aCuuM roCedure Set the Tank Valve to the CLOSED position Disconnect the Extension Hose from the Pressure Module and attach to the Vacuum Module. Turn the Blue Vent Valve to the CLOSED position and attach Image 8: Step 1 clean, dry shop air. NOTE: Clear Exhaust Hose must be directed to an appropriate location because air and coolant mist will exit...
  • Page 7 Watch coolant level in Storage Tank. When Tank is nearly empty turn both the Tank Valve and the 3-Way Air Valve to the CLOSED position. IMPORTANT: Never allow the storage tank to completely empty and thereby allowing air to enter the cooling sys- Image 12: Step 7 tem.
  • Page 8 For product information or to purchase replacement parts CONTACT CUSTOMER SERVICE AT 1-800-824-K-LinE (5546) Local (616) 396-3564 FAX 1-800-528-9138 or (616) 396-8974 cservice@klineind.com http://klineind.com Copyright 2012 K-Line® Industries, Inc. KL34001-200 Rev B 4/12...