Specifications - Siemens Milltronics MMI Instruction Manual

Belt scale
Table of Contents

Advertisement

Specifications

Accuracy
• ± 0.25% of totalization over 5 to 1 operating range
Load Cell
• Construction:
• Excitation:
• Output:
• Non-linearity:
• Hysteresis:
• Non-repeatability:
• Capacity:
• Overload:
• Temperature:
Belt Width
• 18" to 96" in 1" increments to suit CEMA sizes, equivalent to 500 to 2000 mm in metric
sizes
Outline Dimensions
• Refer to
Belt Speed
• Up to 4 m/s (800 fpm)
Capacity
• Up to 5000 t/h (5500 STPH) at maximum belt speed
Conveyor Incline
• ± 20° from horizontal, fixed incline
• Up to ± 30° with reduced accuracy
Conveyor Idler
• Flat to 35°
• Up to 45° with reduced accuracy
Idler Diameter
• 50 to 180 mm (2 to 7")
Idler Spacing
• 0.5 to 1.5 m (1.5 to 5.0 ft)
Page 2
Milltronics MMI Belt Scale – INSTRUCTION MANUAL
Stainless steel with superior moisture protection
10 V DC nominal, 15 V DC maximum
2 mV / V excitation at rated load cell capacity
0.02% of rated output
0.02% of rated output
0.01% of rated output
Maximum ranges: 50, 100, 250, 500, 750, 1000 lb
Maximum 1000% of rated capacity
– 40 to +85 °C (– 40 to +185 °F) operating range
– 15 to +65 °C (0 to +150 °F) compensated
on page 18
7ML19985DR02

Advertisement

Table of Contents
loading