Siemens Milltronics MMI Instruction Manual page 11

Belt scale
Table of Contents

Advertisement

3.
Insert the MSIs in the place of the removed idler. The MSI is designed to use the
existing holes in the stringer and should not require further drilling. Install the
mounting bolts and nuts but do not tighten. Remove the idler clips from the (see
diagram below). Refer to
material flow
Be sure there is sufficient clearance between the return belt, MSI, and its test
Note:
weight (when used during the calibration procedure).
4.
Position the individual MSIs so that they are centered and square to the stringer.
Mount the modified idler so that it is centered on the scale using the idler clips.
Tighten all mounting hardware. Refer to
mounting arrangements.
Position the scale so that the large arrow on the scale mounting brackets is pointing
in the direction of material flow.
conveyor stringer
(typical)
7ML19985DR02
Milltronics MMI Belt Scale – INSTRUCTION MANUAL
Outline Dimensions
test weight(s)
on page 18, for working dimensions.
location of
removed idler
test weight(s)
MSI belt scale
Idler Mounting
on page14 for alternate idler
idler clips
Page 7