Stollmann reserves the right to make changes to the hardware or firmware or to the specifica- tions without prior notice or to replace the device with a successor model.
Application Specific Pin Description ............ 19 4.2.3 SPP Configuration ................19 Electrical Characteristics.................. 20 5.1 Absolute Maximum Ratings ................ 20 5.2 Environmental Requirements..............20 5.3 Operating Conditions .................. 21 5.3.1 RF and Supply Connections..............21 Release r05 www.stollmann.de Page 3 of 44...
Page 4
7.2.3 RF-exposure Statement ..............39 7.2.4 Labelling and re-test requirements for the End Product....... 40 7.3 Bluetooth Qualification ................40 7.4 RoHS Declaration ..................41 Related Documents ..................42 Ordering Information ..................42 Release r05 www.stollmann.de Page 4 of 44...
EDR performance and functionality is not valid. Information regarding EDR per- formance and functionality applies only to the BlueMod+C11/G2 with EDR function- ality enabled. For the latest version of this document please check the following URL: http://www.stollmann.de/en/modules/bluetooth-products/bluemod-c11g2/ 1.1 Feature Summary • Bluetooth specification V2.0+EDR •...
BlueMod+C11/G2 can be used in different applications. Available applications are • Bluetooth SPP • BlueMux Point to Multipoint SPP • BlueCluster Adhoc Networking Please refer the software reference and interface specifications for further informa- tion. Release r05 www.stollmann.de Page 7 of 44...
The following picture shows a sample layout with two linear regulators in SOT23-5 housings and various capacitors in SMT shapes 0402, 0805 and 1206. Fig. 2 Sample Layout Power Supply Release r05 www.stollmann.de Page 9 of 44...
BlueMod+C11/G2 Hardware Reference Each supply rail should be fed with 3,3V, Range 3,0V to 3,6V incl. Noise, low noise from a linear regulator with fast transient response. Stollmann suggest using two pcs. TOREX: XC6204B332MR regulators, so that the fast current transients of the class1 RF power amplifier do not interfere with sensitive PLL circuitry of the low power RF circuitry.
For RS-485 support the serial interface has to be connected to an external Trans- ceiver, we suggest the MAX3491E from Maxim Integrated Products, due to it sup- ports full duplex transmissions. BlueMod+C11/G2 MAX3491E UART_TX UART_CTS UART_RX +3,3V Connections in Full Duplex Mode Release r05 www.stollmann.de Page 11 of 44...
Page 12
BlueMod+C11/G2 Hardware Reference MAX3491E BlueMod+C11/G2 UART_TX UART_CTS UART_RX +3,3V Connections in Half Duplex Mode y tes max character max Figure 4. UART Timing Diagram Release r05 www.stollmann.de Page 12 of 44...
MISO Master In Slave Out GPIO0 MOSI Master Out Slave In GPIO3 SPCK Serial Clock GPIO2 NPCS0 Peripheral. Chip Select Clock polarity and phase are programmable. The chip select signal is low active. Release r05 www.stollmann.de Page 13 of 44...
S&H timing are available. Pin # GPIO# Alternative Description Direction IO Name Signal Name JTAG-RES# ADC channel analogue GPIO10 ADC channel analogue GPIO8 ADC channel analogue Release r05 www.stollmann.de Page 15 of 44...
PCB has to be implemented with 50R micro-strip line technique. If the antenna performance does not meet your requirements or you need antenna support, please contact Stollmann. 3.8 Etc. For SW development purposes on the module pins a full JTAG interface connected to the ATMEL CPU is implemented.
BlueMod+C11/G2 Hardware Reference 4 Pin Description The BlueMod+C11/G2 module is soldered on customers PCB via stamp pins lo- cated on the module PCB edges. 4.1 Pin Numbering Top View Release r05 www.stollmann.de Page 17 of 44...
USB_DM USB D-, Data pin USB_DP USB D+, Data pin +3.3V Power digital and low power RF +3.3V Power RF amplifier Type: PU – pulled up on Module; PD pulled down on Module Release r05 www.stollmann.de Page 18 of 44...
Ring Indicator input in DTE mode, output in DCE mode GPIO5 Reserved I-PU GPIO4 DTE-/DCE I-PD DTE DCE mode selector +3.3V Power +3.3V Power /EXT_RES /EXT_RES Reset low active USB_DM Do not connect USB_DP Do not connect Release r05 www.stollmann.de Page 19 of 44...
ESD protected workstations. 5.2 Environmental Requirements Item Symbol Absolute Maximum Ratings Unit Storage temperature range -40 to +105 ° C Operating temperature range -40 to +85 ° C Release r05 www.stollmann.de Page 20 of 44...
Transmit Mode to 50 load UMP connector Supply voltage The typical voltage is Pin C-13 and recommended Vcc at voltage pin (incl. ripple) Pin C-16 Ripple frequency ≥200kHz Ripple on Vcc mVrms Ripple frequency <200kHz Release r05 www.stollmann.de Page 21 of 44...
If no Bluetooth connection is established, the following states are implemented, the activation of these states can be controlled by the parameters bpsm and pwd. For more details please refer to the BlueMod+C11/G2 software manual. Release r05 www.stollmann.de Page 22 of 44...
≤ -9 Adjacent channel selectivity C/I f = f image Notes: a) For BER less then 0,1%. Applies according to BT Test Specification Ver. 1.2/2.0/2.0 + EDR only for Tamb = 20° C Release r05 www.stollmann.de Page 25 of 44...
Page 26
≤ ±75 Initial carrier frequency tolerance ≤ ±25 Carrier frequency drift (packet DH1) Drift Rate kHz/ 50µs ≥140 ∆f1 “Maximum Modulation” ≤175 ∆f2 ≥ 115 “Minimum Modulation” Notes: b) Including +2dBi antenna gain Release r05 www.stollmann.de Page 26 of 44...
120 us (Sleep state) The module processes commands after 180ms coming from deep sleep state and accordingly after 120us coming from sleep (power-down) state. Serial commands can be sent directly after CTS is active(low). Release r05 www.stollmann.de Page 30 of 44...
Except for the stamp pins A-[1-17,26-28] and C-[1-16] and the UMP antenna connector no user accessible connectors are implemented. If the use of the UMP antenna connector is considered, please contact Stollmann for information on accessories like cables, plugs etc. Or look at www.radiall.com...
BlueMod+C11/G2 Hardware Reference 6.3 Recommended Land Pattern Land pattern recommended for manual soldering Alternative land pattern recommended for reflow soldering(preliminary) Release r05 www.stollmann.de Page 32 of 44...
[min.] Temperature Opposite side re-flow is prohibited due to module weight. Devices will withstand the specified profile and will withstand up to 1 lead-free re- flows to a maximum temperature of 260° C. Release r05 www.stollmann.de Page 33 of 44...
The individual case must be checked to decide whether a specific housing is suit- able for the use of the internal antenna. A plastic housing must at least fulfill the fol- lowing requirements: • Non-conductive material, non-RF-blocking plastics • No metallic coating • ABS is suggested Release r05 www.stollmann.de Page 34 of 44...
It must be ensured that the antenna is not co-located or operating in conjunction with any other antennas, transmitters, cables or connectors. When the internal ce- ramic antenna is used, certain restrictions are to be considered. Antenna – recommended restricted area Release r05 www.stollmann.de Page 35 of 44...
Page 36
The best position to place the BlueMod+C11/G2 on the target PCB is in the upper right corner. This position is optimal concerning antenna interference; radiation pat- tern and PCB space that has to be keep free for the restricted area. recomendable placement Release r05 www.stollmann.de Page 36 of 44...
BlueMod+C11 are to be classified as SELV circuitry. OEM’s implementing the BlueMod+C11/G2 in their products should follow the isolation rules given in regula- tion EN 60950-1: 2001. The PCB material of the BlueMod+C11/G2 is classified UL-94V0. Release r05 www.stollmann.de Page 37 of 44...
7.2.1 Caution Warning: Changes or modifications made to this equipment not expressly approved by Stollmann Entwicklungs und Vertriebs GmbH may void the FCC authorization to operate this equipment. 7.2.2 FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
According to the Bluetooth SIG rules (Qualification Program Reference Document – PRD V2.1) you are required to perform the mandatory End Product Listing (EPL) for your product. For further information see www.Bluetooth.org or contact Stollmann. Release r05 www.stollmann.de Page 40 of 44...
• Mercury and mercury compounds • Chromium (VI) • PBB (polybrominated biphenyl) category • PBDE (polybrominated biphenyl ether) category and a maximum concentration of 0,01% by weight in homogeneous materials for Cadmium and cadmium compounds Release r05 www.stollmann.de Page 41 of 44...
The BlueMod+C11/G2 is available in the following variants: Name Antenna Art No. BlueMod+C11/G2/AI/SPP Internal 52672 BlueMod+C11/G2/AE/SPP External 52733 BlueMod+C11/G2/AP/SPP External 52742 SPP Evaluation Kit Internal 52743 BlueEva+C11/G2/SPP, Other variants on request, please contact Stollmann sales department. Release r05 www.stollmann.de Page 42 of 44...
Page 43
URL link to active document version added in chapter 1 Introduction 04.09.2009 changed requirements for GND pins in chapter 3.7 Bluetooth radio Interface and 4.2.1General Pin Description JW updated chapter 7.1 Declaration of conformity Release r05 www.stollmann.de Page 43 of 44...
Page 44
Hardware Reference Life Support Policy This Stollmann product is not designed for use in life support appliances, devices, or systems where malfunction can reasonably be expected to result in a significant personal injury to the user, or as a critical component in any life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.