Meiko GiO Module Operating Instructions Manual

Meiko GiO Module Operating Instructions Manual

Integrated reverse osmose

Advertisement

Operating instructions
Integrated reverse osmose
GiO Module
TRANSLATION OF THE "ORIGINAL OPERATING INSTRUCTIONS"
The original operating instructions can be downloaded from: https://partnernet.meiko.de
9661928
1/14
Datei:BA_GiO-Modul_9661928_EN_2008-04.docx
Update: 2018-08-10
W e reserv e the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GiO Module and is the answer not in the manual?

Questions and answers

Summary of Contents for Meiko GiO Module

  • Page 1 TRANSLATION OF THE "ORIGINAL OPERATING INSTRUCTIONS" The original operating instructions can be downloaded from: https://partnernet.meiko.de 9661928 1/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx Update: 2018-08-10 W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 2: Table Of Contents

    3.7.1 Connection plan - GiO module M-iClean U-Series for the UK Troubleshooting / Maintenance 9661928 2/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 3: Introduction And General Information

    GiO Module Variants GiO-Modul „base“ GiO module „Rear wall“ GiO module "separately added“ 9661928 3/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 4: Connection / Installation

    - Flush the diaphragm set for 5 minutes - Perform measurements and document in the commissioning protocol 9661928 4/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 5: Gio With Airconcept

    9661928 5/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 6: Installation

    After the GiO module Drain set/ Install free outlet for concentrate line 9661928 6/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 7: Circuit Function Diagram

    See technical sheet For connection do not use more than three 90° bends 9661928 7/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 8: Circuit Function Diagram Option (Connection Ba System Separator As Per En 1717)

    See technical sheet For connection do not use more than three 90° bends 9661928 8/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 9: Connection's Plan - Gio-Modul Fv 40.2, Fv40.2G (-K), Fv 60.2, Topclean 60, Et8-M Os, Upster U 500 M2, Upster U 500G M2

    For connection do not use more than three 90° bends 9661928 9/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 10: Connection's Plan - Gio-Modul Et 15-M Os / Dv200.2 / Fv130.2 / Fv250.2 / Dv270.2 / Upster H 500 M2

    For connection do not use more than three 90° bends 9661928 10/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 11: Connection's Plan - Gio Module M-Iclean U-Serie

    For connection do not use more than three 90° bends 9661928 11/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 12: 3.7.1 Connection Plan - Gio Module M-Iclean U-Series For The Uk

    For connection do not use more than three 90° bends 9661928 12/14 Datei:BA_GiO-Modul_9661928_EN_2008-04.docx W e reserv e the right to change execution and construction! MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121...
  • Page 13: Troubleshooting / Maintenance

    The dishwasher may only be switched on if this is the case. Troubleshooting / Maintenance The machine control merely monitors that the GIO module produces enough clean water. Any malfunction of the module is thus displayed as lack of water on the display (ERR 201 / ERR 202).

Table of Contents