transmit:AT+DEV=?
return:DEV= type<CR><LF>
Parameter: type
C coordinator
R router
E terminal
e.g:AT+DEV=C
Default:DEV=E
AT+EXIT
Function:exit temporary AT command(valid when pull low P1_6 pin to be in AT mode)
Format:
configure
transmit:AT+EXIT
return:+OK<CR><LF>
e.g:AT+EXIT
AT+MODE
Function:inquire /configure operating mode
Format:
Inquire
transmit:AT+MODE=?
return:MODE=type<CR><LF>
configure
transmit:AT+MODE=mode
return:+OK<CR><LF>
Parameter:mode
1 mode 1 (transparent transmission mode)
2 mode 2 (half transparent transmission mode)
3 mode 3 (protocol mode)
e.g:AT+MODE=3
default:MODE=3
AT+RMODE
Function:inquire /configure communication display mode
Format:
inquire
transmit:AT+RMODE=?
return:RMODE=type<CR><LF>
configure
transmit:AT+RMODE=type
return:+OK<CR><LF>
Paremeter: rmode(1 on 0 off ; value:0-7 )