• Retain this manual for future reference. INTRODUCTION This publication contains information regarding the installation and operation of Duke Refriger-ated Counter units. The information contained within applies to the models RUF 48. Please read this manual completely before attempting to install and/or operate this equipment.
8. Retain all shipping material until an inspec¬tion has been made or waived. SPECIFICATIONS Figure. 2 RUF 48 Frequency Watts Model Volts Amps HEIGHT WIDTH LENGTH (Hz) (Label) RUF-48 M 40.00 In. 29.50 In. 48.18 In. RUF-48 M 40.00 In. 29.50 In. 48.18 In. RUF-48 M 40.00 In. 29.50 In. 48.18 In.
Installation and Operation of: Refrigerated Counter RUF48 Digital INSTALLATION INSTALLATION - LOCATION Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor or count- er strong enough to support the total weight of the units. Reinforce the floor or counter if necessary to provide for maximum loading.
Installation and Operation of: Refrigerated Counter RUF48 Digital OPERATION OPERATION – Location of Controls The refrigeration control/temperature setting adjustment is located on the back splash. This is the only user adjust- able component on the unit. OPERATION – Operating Procedure Press and hold the (i) button to display setpoint.
Page 7
Installation and Operation of: Refrigerated Counter RUF48 Digital MAINTENANCE WARNING NEVER USE AN ACID BASED CLEANING SOLUTION! MANY FOOD PRODUCTS HAVE AN ACIDIC CONTENT WHICH CAN DETERIORATE THE FINISH. BE SURE TO CLEAN ALL FOOD PRODUCTS FROM ANY STAINLESS STEEL SURFACE. COMMON ITEMS INCLUDE, TOMATOES, PEPPERS AND OTHER VEGETABLES.
The drain pan and drain tube can be accessed from the rear of the unit. Pull the unit away from wall to expose the rear of the cabinet. The drain pan is located on the left/rear of the unit. NOTES Phone: 314-231-1130 Duke Manufacturing Co. Toll Free: 1-800-735-3853 2305 N. Broadway www.dukemfg.com Fax: 314-231-5074 St.