BEAMEX POC8 User Manual

Automatic pressure controller
Table of Contents

Advertisement

Quick Links

AUTOMATIC PRESSURE CONTROLLER
Dear user,
We have made every effort to ensure the accuracy of the contents of this manual.
Should any errors be detected, we would greatly appreciate to receive suggestions
to improve the quality of the contents of this manual.
The above notwithstanding, we can assume no responsibility for any errors in this
manual or their eventual consequences.
We reserve rights to make modifications to this manual without any further notice.
For more detailed technical data about the Beamex® POC8 Automatic Pressure
Controller, please contact the manufacturer.
© 2017
BEAMEX OY AB
Ristisuonraitti 10
FIN-68600 Pietarsaari
FINLAND
Tel
Fax
E-mail:
Internet:
Beamex
User Manual
+358 - 10 - 5505000
+358 - 10 - 5505404
sales@beamex.com
https://www.beamex.com
POC8
®
8888500 / POC8uEng / Version 1.0a

Advertisement

Table of Contents
loading

Summary of Contents for BEAMEX POC8

  • Page 1 The above notwithstanding, we can assume no responsibility for any errors in this manual or their eventual consequences. We reserve rights to make modifications to this manual without any further notice. For more detailed technical data about the Beamex® POC8 Automatic Pressure Controller, please contact the manufacturer. © 2017...
  • Page 2 This Warning symbol indicates that danger of injury for persons and the environment and/or considerable damage (mortal danger, danger of injury) will occur if the respective safety precautions are not taken. This Caution symbol indicates danger for the system and material if the re- spective safety precautions are not taken.
  • Page 3: Table Of Contents

    Turning On ................. 5 Front Panel ................6 Power Switch ..............6 USB Port ................6 Display ..................7 Chassis Assembly ..............8 Specifications ................. 9 Measure Specification ..............9 Control Specifications ..............9 General Specifications ............. 10 Beamex® POC8 Automatic Pressure Controller...
  • Page 4 Information View .............. 39 Troubleshooting View ............40 Remote Settings View ............41 Step Settings View ............43 Leak Test ................. 45 Burst Test ................. 46 Service View ..............47 Unlocked Service View ............ 48 Beamex® POC8 Automatic Pressure Controller...
  • Page 5 Contents Remote Operation ..............49 Command Set ................49 Operation with Beamex calibrators ........49 IEEE-488 .................. 50 IEEE-488.2 Commands ........... 50 Ethernet ................... 51 USB device (Virtual Serial Port) ..........51 Serial ..................52 Serial Cable Requirements ..........52 Command and Query Format ..........
  • Page 6 One Point Calibration ............... 76 Two Point Calibration ............... 77 Linearization ................78 Head Pressure ................. 80 Appendix ................81 Measurement Units ..............81 Conversion Factors, PSI ............82 Conversion Factors, millitorr ............ 83 Conversion Factors, Pascal ............. 84 Beamex® POC8 Automatic Pressure Controller...
  • Page 7 There are however no definite re- strictions; fill in the form when you feel like it (all items need not be an- swered). Then send it to Beamex using one of the possibilities listed below. Mail:...
  • Page 8 ___________________________________________________________ Did anything in the product disappoint you? In that case, please specify. ___________________________________________________________ ___________________________________________________________ 10. Any ideas You want to propose to Beamex so that we can improve our products, operations and/or services. ___________________________________________________________ ___________________________________________________________ Title & Name: _________________________ ...
  • Page 9: General Information

    Beamex is a registered trade mark of Beamex Oy Ab. Packaging for Shipment If the product must be shipped to a different location or returned to Beamex for any reason through a common carrier it must be packaged properly to minimize the risk of damage.
  • Page 10: Safety Notices

    Extreme care must be taken with pressure connections when using hazard- ous or toxic media. Repairs must only be performed by authorized service personnel. Additional safety notices are found throughout this manual. Beamex® POC8 Automatic Pressure Controller...
  • Page 11: Warnings And Caution Notices

    (printed circuit boards) to prevent static discharge to sensitive electronic components. Additional Warning and Caution notices are found throughout this manual. Beamex® POC8 Automatic Pressure Controller...
  • Page 12: General Description

    General Description General Description POC8 is a bench top or rack mounted Pressure Controller used for test and calibration of me- chanical pressure gauges, sensors, transducers, transmitters and any pressure related devices where time to set point is a critical requirement.
  • Page 13: Turning On

    Ventilation! Do not block airflow to ventilating fans located on rear of instrument. To see information about the configuration of your new POC8, touch the Next Page Button ] then the Information view icon [ ] on the menu and a window will appear listing the Beamex customer service contact, model number and the modules that are installed.
  • Page 14: Front Panel

    General Description Front Panel The POC8 front panel includes a 7” color LCD display with touch screen. Operator input is ac- complished by pressing the words or symbols and the button icons presented on the display. There is a single discrete on/off button and a USB port on the right hand side.
  • Page 15: Display

    Up to three auxiliary displays can be shown simultaneously along with the current pressure value. The operating mode of the instrument can be selected and changed in this screen between “Measure”, “Control” and “Vent”. Beamex® POC8 Automatic Pressure Controller...
  • Page 16: Chassis Assembly

    Each measurement module includes its own on-board compensation and calibration data so that any module can be replaced in the instrument without requiring a recalibration. Pressure Measurement Module. Beamex® POC8 Automatic Pressure Controller...
  • Page 17: Specifications

    < 0.3% FS in fast control mode (typical < 0.01% FS in slow control mode) Supply Consumption < 70.8 l / < 2.5 standard cubic feet per hour in steady-state control Test Volume 0 to 1000 ml; The controller auto compensates volumes from 0 to 500 ml Beamex® POC8 Automatic Pressure Controller...
  • Page 18: General Specifications

    Japanese, Korean Measurement Filters Off, Low, Normal (default), High Pressure ports 4 ports with 7/16”- 20 F UNF including adapters to Beamex low/high pressure hoses (vacuum and pressure supply hoses are included) Optional Barometer: 10-32 UNF female port Filter Elements...
  • Page 19: Installation

    The following items are included in the standard delivery:  POC8 Automatic Pressure Controller  Calibration certificate  This User Guide  Power Cord  Vacuum connection hose and connectors  Supply pressure connection hose and connectors Beamex® POC8 Automatic Pressure Controller...
  • Page 20: Dimensions In Mm / Inches

    Installation Dimensions in mm / inches Front view, standalone instrument. Side view, standalone instrument. Front view, rack mounted instrument. Beamex® POC8 Automatic Pressure Controller...
  • Page 21: Mounting

    Five pressure connections are on the rear panel. Plugged connections are not used. All pressure ports on the rear apart from the Vent Port are female 7/16” - 20 F UNF. Beamex provides pressure connectors and vacuum and supply hoses with the device. Pressure hoses for output pressure are optional accessories.
  • Page 22: Supply Port

    15. The main screen may be configured in many different ways but initially it will be in a de- fault configuration. Subsequently, the unit will power up in the configuration that it was in when last powered off. Allow at least 15 minutes of warm up before performing critical pressure meas- urements. Beamex® POC8 Automatic Pressure Controller...
  • Page 23: Local Operation And Setup

    Remote Operation on page 49. By following the procedures provided in these two chapters and chapter Calibra- tion on page 74, you can expect your POC8 to deliver maximum accuracy and dependability for many years of useful service.
  • Page 24: Initial Setup

    This gives access to the second page of the button selection area. Press the Information view button [ ] to display Beamex contact, installed pressure control unit and pressure measurement modules along with instrument and software version in- formation.
  • Page 25: Settings Views' Parameter Inputs

    ] above the input area. The purpose and use of each selection and menu is intui- tively apparent and will become second nature with minimal exposure to the menu structure. Window title Menu Button Input Title Settings Views. Beamex® POC8 Automatic Pressure Controller...
  • Page 26: Main Functions

    ("Pressure units" picture); notice that the Units button has a lighter background when the selec- tion menu is active. If a barometric reference is installed, the Mode button, described below, will toggle from Gauge to Absolute mode when pressed. Home view. Single channel display. Pressure units. Beamex® POC8 Automatic Pressure Controller...
  • Page 27 The Setpoint button allows the user to enter the desired pressure value to be controlled by the POC8. There are multiple ways of entering the control setpoint; numeric keypad, step incre- ments, percentage entry, digital step or a program data entry. These methods can be accessed by the user by pressing the “Setpoint”...
  • Page 28 If the Enter button is pressed the newly entered value will register as a new setpoint value on the Home Screen rather than a step value. Numeric Keypad Setpoint Entry. Step increment buttons highlighted. Beamex® POC8 Automatic Pressure Controller...
  • Page 29 Step corresponds to the least significant digit of the setpoint. Each digit of the setpoint can then be increased or decreased by pressing the Up [ ] or Down [ ] button. Digital Step Entry. Beamex® POC8 Automatic Pressure Controller...
  • Page 30 This bar graph will appear in the Home view when selected from the Display Settings presented on page 35. Beamex® POC8 Automatic Pressure Controller...
  • Page 31 Units: Pressing the Auxiliary Units button will display the same set of units available for the pri- mary units. Pressing any of these units will change the auxiliary units to that chosen unit. Beamex® POC8 Automatic Pressure Controller...
  • Page 32 Pressing the tare button again will deactivate the tare and change the pressure indication back to the reading corresponding to the calibrated output of the measurement module. An active tare will revert to a deactivated state after a power cycle. Beamex® POC8 Automatic Pressure Controller...
  • Page 33 Venting will cause a loss of pressure at the vent rate in the system and the plumbing connected to the measure control port. Care must be taken that the device under test is not damaged during venting. Beamex® POC8 Automatic Pressure Controller...
  • Page 34: Settings View

    (.) to a comma (,) depending on the language chosen. More lan- guages can be accessed by navigating to the next page of the language selection menu on the right side of the screen. Languages. Beamex® POC8 Automatic Pressure Controller...
  • Page 35 After the setting is made and your finger is removed from the screen the menu will show the brightness percent selected. Brightness. Volume The Volume setting provides a way to turn on or off the touch screen audio feedback. Volume. Beamex® POC8 Automatic Pressure Controller...
  • Page 36 Any of these units can be chosen from this list for the barometric readout that can be seen on the bottom right of the Home view. Barometer units. Beamex® POC8 Automatic Pressure Controller...
  • Page 37 Settings-Configuration and press the numbered config- uration button corresponding to the saved configuration and then press the “Load” button. Configuration. The instrument default configuration can be activated simply by pressing the “Default” Button. Beamex® POC8 Automatic Pressure Controller...
  • Page 38: Control Settings

    The first two pictures below show the Control Settings view. The lowermost picture shows the first page of the Control Settings view in “High-Speed” control modes. Control Settings. Control Settings. High Speed control mode. Beamex® POC8 Automatic Pressure Controller...
  • Page 39 The Rate Setpoint button allows the user to set the rate of pressure change when the device is controlling up or down to a setpoint (picture below). The rate is limited to 0.001% of span of ac- tive range of the measurement module/second to 20% of the full scale range/second. Rate Setpoint. Beamex® POC8 Automatic Pressure Controller...
  • Page 40 “cc”. The device is capable of automatically identifying the control pressure volume and adjusting the control parameters based on it. By default this button is set on “Auto”. The picture below displays the control volume setting for the instrument. Control Volume. Beamex® POC8 Automatic Pressure Controller...
  • Page 41 By default the rate of the vent is set similar to the control rate. The rate is limited to a maximum of 20% of the full scale range/ second. The picture below dis- plays the vent rate setting for the instrument. Vent rate. Beamex® POC8 Automatic Pressure Controller...
  • Page 42 Rate parameters highlighted. Detection Flags POC8 is equipped with three detection flags that can be enabled or disabled by the user as needed. These detection flags appear in the Control Settings view. The primary purpose of these detection flags is to protect the device and to ensure desired operation. Each of these flags can be turned “On”...
  • Page 43: Display Settings

    Turn off the Filter by selecting “Off”, select varying degrees of filtering for the current units by selecting “Low”, “Normal” or “High”. Reading Filter. Beamex® POC8 Automatic Pressure Controller...
  • Page 44 Home view. The Tare button and the Zero Button cannot appear on the screen at the same time. See chapters Zero Button on page 24 and Tare Button on page 24 for operation of the Zero and Tare buttons in the Home view (main screen). Cal Function. Beamex® POC8 Automatic Pressure Controller...
  • Page 45: Programs

    ] button will accept the changes, pressing the [ ] will revert back to the old program. A list of available commands, data values and their functions are listed in the table on next page. Editable programs view. New line creation. Beamex® POC8 Automatic Pressure Controller...
  • Page 46: Favorites View

    Programs view where the program can run be by clicking on the Play [ ] button. A maximum of eight programs can be stored as favorites. Favorites view. Play button highlighted. Beamex® POC8 Automatic Pressure Controller...
  • Page 47: Information View

    ] displays information about the device, including:  Beamex address, and email  Model number, serial number and operating software version.  Control unit, serial number and software version.  Pressure measurement module(s), range, serial number, and software version. Information view. Beamex® POC8 Automatic Pressure Controller...
  • Page 48: Troubleshooting View

    ] will appear in all screens (lowermost picture below). Pressing this error button from any screen will open the Troubleshoot view where the error can be viewed. Troubleshoot error view. Troubleshoot remote view. Error indication. Beamex® POC8 Automatic Pressure Controller...
  • Page 49: Remote Settings View

    Remote Settings view, page 2. Remote Command Set The remote command set parameter provides a choice of the Beamex, SCPI or DPI5xx com- mand set. The Beamex commands are listed in chapter Remote Operation on page 49. Remote Command Sets.
  • Page 50 DHCP server. A successful communication link between the instrument and the various interfaces is indicated by a Remote Settings Icon [ ] at the top of the screen. Beamex® POC8 Automatic Pressure Controller...
  • Page 51: Step Settings View

    5% over the range of the device under test limits by entering the overrange percentage (lowermost picture below). POC8 automatically calculates the pressure value of the setpoint based on this selection. The user can be directed to this view from the set- point entry menu in chapter Home View on page 18.
  • Page 52 For example if the user needs 6 distinct points along the DUT range then enter 6 in the numeric keypad and press Enter [ ] button. POC8 will create setpoints at 0%, 20%, 40%, 60%, 80% and 100% of the DUT range. The user also has the op- tion of changing these percentage values by clicking on the individual Percentage button on the Step Settings view.
  • Page 53: Leak Test

    “failed” test. Otherwise it will return a green status indication showing that the delta was not exceeded for the time period, indicating a “passed” test. Leak Test. Setpoint entry. Delta entry. Beamex® POC8 Automatic Pressure Controller...
  • Page 54: Burst Test

    The burst test is initiated by pressing the Start button. The status of the test is shown next to the pressure reading (lowermost picture). Burst test screen. Burst test - status. Beamex® POC8 Automatic Pressure Controller...
  • Page 55: Service View

    Default password is 123456. Enter 123456 and press the check mark [ ] to unlock the Service view. Service view. Entering a password. The default Password is 123456. After entering this for the first time, the password can be changed. Beamex® POC8 Automatic Pressure Controller...
  • Page 56: Unlocked Service View

    The Unlocked Service view is the access point to all calibration screens described in Section 10 of this manual. Note: Recommended calibration setup and explanation of calibration screen is covered in chapter Calibration on page 74 of this manual. Beamex® POC8 Automatic Pressure Controller...
  • Page 57: Remote Operation

    Command Set button – Users can select which model remote protocol they would like to emu- late for simulation and testing purposes. Selections may include the following: Beamex (default) SCPI DPI5xx Operation with Beamex calibrators Connect the POC8 to the calibrator as shown below: Beamex® POC8 Automatic Pressure Controller...
  • Page 58: Ieee-488

    Clear status and error queue *ESE Enable status event *ESE? Returns enable status even value *ESR Event status register *ESR? Returns even status register value *SRE Service request enable *SRE? Returns service request enable value *STB? Returns status byte Beamex® POC8 Automatic Pressure Controller...
  • Page 59: Ethernet

    Port. USB device (Virtual Serial Port) The USB virtual serial communication port allows the POC8 to communicate with USB hosts, while retaining the semantics of legacy serial ports for application level. Settings are fixes as: 57600 baud, 8 data bits, 1 stop bit, no parity.
  • Page 60: Serial

    8 data bits, 1 stop bit, no parity, and no echo. If echo is ON, the POC8 will immediately echo back characters sent over the serial port. The Serial function allows the user to set the RS-232 serial port settings by selecting from the...
  • Page 61: Command And Query Format

    [Command?] [Termination] where the question mark, “?”, immediately precedes the terminator. When a valid query is received, the POC8 will return {data} terminated by CR and LF. Floating point data is returned in the current engineering units in exponential format.
  • Page 62: Output Formats

    <sp> pressure, pressure rate <cr><lf> <sp> pressure, minimum peak, maximum peak <cr><lf> <sp> pressure, active sensor (P or S) active turndown (1-4)<cr><lf> <sp> pressure, control point, “stable” or “slewing”<cr><lf> <sp> pressure, “no barometer” or baro reading<cr><lf> Beamex® POC8 Automatic Pressure Controller...
  • Page 63: Commands And Queries

    Caldisable? <sp>(YES or NO)<cr><lf> Returns whether or not calibration of the active module is disabled. Calspan Current Pressure Sets the internal span multiplier to achieve the sent pressure. Sending a “?” clears internal span Beamex® POC8 Automatic Pressure Controller...
  • Page 64 Reserved for DHCP setup DOC? <sp>mm/dd/yyyy<cr><lf> Returns the date of cal for the active pressure module. DOM? <sp>mm/dd/yyyy<cr><lf> Returns the date of manufacture Error? <sp> text description Returns the next error in the error <cr><lf> queue Beamex® POC8 Automatic Pressure Controller...
  • Page 65 Returns the segment intercept for the point List? <sp>Pri,1;Sec,1;Ter,1;Bar,1 Returns list of available pressure mod- <cr><lf> ules and turn downs. Turn downs are obsolete and therefore set to 1 for backwards compatibility. Listcal? <sp>PRI,{sn},1,{mmddyy};S EC,{sn},1,{mmddyy},TER,{s n},1,{mmddyy}, Bar,{sn},{ mmddyy}<cr><lf> Beamex® POC8 Automatic Pressure Controller...
  • Page 66 4 second stable delay Sets the instrument pressure type – Ptype Absolute or Gauge emulation only works if the optional bar- ometric module is installed Returns “Absolute” or “Gauge” for the Ptype? <sp>CCCCC<cr><lf> pressure type Beamex® POC8 Automatic Pressure Controller...
  • Page 67 Sets rate Butterworth corner frequency Rfreq? <sp>n.nnnnnE+nn<cr><lf> Returns rate Butterworth corner fre- quency Rwindow Value in current units Sets rate exponential filter window Rwindow? <sp>n.nnnnnE+nn<cr><lf> Returns rate exponential filter window Save_cal Save calibration values Save_linearity Save linearity values Beamex® POC8 Automatic Pressure Controller...
  • Page 68 <sp>CCCC<cr><lf> Returns the serial parity Srqmask Stable,Error or both Sets the POC8 to issue a service re- quest (SRQ) over the IEEE when the pressure Control is stable, or an error occurs. These are 80 hex and 40 hex respectively Returns “stable”, ”error”...
  • Page 69 Returns the exponential filter window for the active pressure module Zero desired pressure or ? Sets zero to set pressure or for ?, clears previous value. CALDISABLE must be OFF/NO. Zero? <sp>n.nnnnnE+nn<cr><lf> Returns zero offset for active pressure module Beamex® POC8 Automatic Pressure Controller...
  • Page 70: Units Command Syntax For Measurement Units

    @ 0°C Metric tons per square Imperial hectapascals Metric megapascals Metric millimeters of water @ 20°C MMH2O Metric CMH2O centimeters of water @ 20C Metric meters of water @ 20°C MH2O Metric Beamex® POC8 Automatic Pressure Controller...
  • Page 71: Error Codes

    Not used, kept for backwards compatibility :TIME? Not used, does not cause an error, dose not return a re- sponse :ERRor[:NEXT]? Returns error code, description :KLOCk ON | OFF | 1 | 0 Sets the keylock state Beamex® POC8 Automatic Pressure Controller...
  • Page 72 Returns the mode string :STABle? Returns 1 if stable 0 if not :AUTOvent ON | OFF | 1 | 0 Autovent is always true on POC8 :AUTOvent? Returns the state of the Vent mode :AUTORange ON | OFF | 1 | 0 Turns autorange on or off Beamex®...
  • Page 73: Gpib Capability Codes

    :DETECT? GPIB Capability Codes All remote commands sent to the POC8 are shown in the Trouble Shooting view, under the “Re- mote” button. If there is a syntax error, an error message will appear below the errant command. Local errors and remote command errors will appear under the “Error” button. Maximum of 100 errors are stored and can be retrieved.
  • Page 74: Interface Functions

    Remote Operation Interface Functions POC8 responds to the following IEEE.488.2 interface functions: Service Request: A service request is asserted whenever an error is encountered. When the bus controller issues a serial poll the error will be cleared. If the host IEEE board includes automatic serial polling capability, turn this feature off in order to view all errors.
  • Page 75: Usb Software Upgrade

    The instrument software can be upgraded to the most recent release by copying the instrument software from the Beamex website onto a USB device. The user can then plug the USB device to the USB port on the front panel of the instrument for an easy upgrade. The instrument recog- nizes this device by displaying a USB icon on the top bar of the screen (uppermost picture be- low).
  • Page 76: Options

    6 bar / 87 psi (9891880) o 20 bar / 290 psi (9891890) o 100 bar / 1450 psi (9891900) o 210 bar / 3045 psi (9891910) o Special range, contact Beamex (9891920)  Bench Mounting Kit (9891850) ...
  • Page 77: Barometric Module

    This module is in a different housing compared to the regular modules. It is removable by taking off the top cover of the chassis. The POC8 uses the barometric pressure, measured by the barometric module, for pressure mode emulation in the channels. If a barometric module is installed the Pressure Mode button in the Home view (main screen) will become active and, when pressed, will toggle between Abso- lute and Gauge mode (see chapter Home View on page 18).
  • Page 78: Additional Measurement Modules

    Secondary Module slot. For complete installation instructions see chapter Removing the measurement module on page 72. Bench Mounting Kit A rack mount kit is used to install POC8 into Beamex MCS200 Calibration Workstation. POC8 Rack Mount Kit. Fittings POC8 is delivered with proper pressure connectors and hoses for supply pressure and vacuum.
  • Page 79: Re-Calibrating

    Beamex Dirt and Moisture trap allow the user to operate POC8 in contamination prone areas. It prevents in > 90 % efficiency contaminants like any liquids, oil or dirt to enter POC8 when the direction of pressure flow is from device under test (DUT) to POC8 or when the device under test is vented.
  • Page 80: Maintenance

    1. VENT THE SYSTEM by placing the device in vent mode. Then turn off the power. 2. Loosen the five Philips screws on the top cover of the device as seen in picture "Top view of POC8" below and open the top cover to reveal the insides of the chassis (picture "Chassis assembly").
  • Page 81: Troubleshooting

    If faults cannot be corrected locally, immediately take the system off line and protect it from unintentional restarts. Contact Beamex for further in- structions. Servicing of electrical, electronic or pneumatic equipment must be performed by qualified and authorized technical staff, observing all relevant safety regulations.
  • Page 82: Calibration

    The recommended calibration medium is dry nitrogen or clean dry instrument air. A height varia- tion between the standard and the POC8 can cause significant errors. A calculation should be made to compensate for this difference. This compensation can be done as presented in chap- ter Head Pressure on page 80.
  • Page 83: Service View (Unlocked)

    Check [ ] button. Please make note of a password change and save the new password in a secure location. The Unlocked Service view is the access point to all calibration screens described further on. Beamex® POC8 Automatic Pressure Controller...
  • Page 84: Calibration Data

    If you want to save the value in the module, press Save. Notice the reference symbol [ ]. This is a reference indica- tion giving a constant reference point for the level of the inter- nal sensor. One point calibration. Beamex® POC8 Automatic Pressure Controller...
  • Page 85: Two Point Calibration

    “Low Reading” by pressing the Low Reading button and en- ] button. Record the “true pressure” ob- tering the number followed by the Check [ tained from the reference standard and enter it as the “Low Reference” value in the same manner. Beamex® POC8 Automatic Pressure Controller...
  • Page 86: Linearization

    Linearization Matrix. Linearization of each measure- ment module can be performed from this screen by selecting module channel using the channel button in the top left hand corner. Linearization Setup. Beamex® POC8 Automatic Pressure Controller...
  • Page 87 POC8. Each value from the standard can be entered under the reference col- umn, corresponding Upscale and Downscale readings from the device can be entered in the “Upscale”...
  • Page 88: Head Pressure

    The Head Pressure view is placed under the password protected area of the operator interface to safeguard against inadvertent activation. It is intended to be used to accurately measure the pressure at an external source that is at a different elevation from the POC8 measurement mod- ule sensing that pressure.
  • Page 89: Appendix

    HG @ 0°C µHg 0°C ton per square inch hectopascals megapascals millimeters of water @ 20°C mmH2O 20°C centimeters of water @ 20°C cmH2O 20°C meters of water @ 20°C mH2O 20°C User Units 1 User defined Beamex® POC8 Automatic Pressure Controller...
  • Page 90: Conversion Factors, Psi

    0.072 13.88889 (PSI / RANGE) x 100 (% FS x RANGE) / 100 µHg 0°C 51715.08 0.00001933672 0.0005 2000 68.94757 0.01450377 0.006894757 145.0377 mmH2O 20°C 704.336 0.001419777 cmH2O 20°C 70.4336 0.01419777 mH2O 20°C 0.704336 1.419777 Beamex® POC8 Automatic Pressure Controller...
  • Page 91: Conversion Factors, Millitorr

    735.561166 kg/cm2 0.000001359506 735561.166 MSW 0°C 3.5% salinity 0.00001322347 75623.11663 0.0003093875 3232.1992 0.002784488 359.132477 0.000001392244 718265.0575 µHg 0°C 1.000000022 0.001333220 750.0636259 0.0000001333220 7500636.259 mmH2O 20°C 0.01361955 73.42388114 cmH2O 20°C 0.001361955 734.2388114 mH2O 20°C 0.00001361955 73423.88114 Beamex® POC8 Automatic Pressure Controller...
  • Page 92: Conversion Factors, Pascal

    9.806647E+04 MSW 0°C 3.5% sal 9.918444E-05 1.008222E+04 2.320603E-03 4.309223E+02 2.088543E-02 4.788025E+01 1.044271E-05 9.576052E+04 µHg 0°C 7.500636E+00 1.333220E-01 7.251885E-08 1.378951E+07 1.00000E-02 1.00000E+02 1.00000E-06 1.00000E+06 mmH2O 20°C 1.021553E-01 9.789017E+00 cmH2O 20°C 1.021553E-02 9.789017E+01 mH2O 20°C 1.021553E-04 9.789017E+03 Beamex® POC8 Automatic Pressure Controller...
  • Page 93 Appendix Notes Beamex® POC8 Automatic Pressure Controller...
  • Page 94 Appendix Beamex® POC8 Automatic Pressure Controller...
  • Page 95 Appendix Beamex® POC8 Automatic Pressure Controller...

Table of Contents