Page 2
Preface MiniMech, is the name of a Talaris Dispenser for ATM use. The manual comprises instructions for installation of MiniMech; • data for preparation of the site • instructions for installation, mechanically as well as electrically • instructions for operating the Minimech...
site preparation general General This section describes different alternatives of instal- Recommendations for transporting, pulling and lation and other general requirements. lifting MiniMech The original packaging is designed to ensure When planning the MiniMech installation, the follow- safe travel for the MiniMech. We therefore rec- ing "four modes of operation"...
The +24 VDC must not exceed 30 volts. Additional On request Talaris can supply a power supply, A008263, MiniMech. to run the As an option Talaris can supply a std RS 232 com- munication cable - refer to page 13.
site preparation dimensions MiniMech dimensions All dimensions in millimetres (mm) � ����� ������ �� ������� ��������� � ��� ����� � ����� ����� ����� ����� ���� ���� �������������� ��� ��� Note Dimension 122.7 is the measurement between the mounting holes at the front of the MiniMech and the center of the note.
site preparation dimensions Delivery slot dimensions The most important item when integrating the MiniMech into a cabinet is that the delivery slot of the MiniMech is correctly aligned to the slot in the cabinet. If the MiniMech is moved out from and into the cabinet e.g.
site preparation required space upon service and maintenance For refilling • The space in front of the MiniMech is required for removing and inserting the note compart- ment ������� ������� For operator maintenance • The space in front of the MiniMech is required for removing and inserting the note compart- ment •...
site preparation connections Note! * Never connect the machine to anything else then +24 V +-10%. * The Power Supply( DLRS or the ATM- ps ) Must be switched off when the power connector of the MMC is fitted. Power Connector The power connector is of type AMP MTA 156-2.
D016128-02 Talaris can offer a std RS-232 communication cable, P/N A008081, as an option. If it is prefered to use other communication cables, Talaris recommends the following: Connector, D-SUB 25, AMP 748 051-1, shielded Connector, D-SUB 9, AMP 748 047-1, shielded...
operating the MiniMech Setup Start the test program and set the appropriate com- munication settings in the Set Up tab. Make sure all settings matches the hardware configurations on the machine and communications cable. The image shows the default settings. Dispensing To operate the MiniMech, the following commands are normally needed.
clearing note table Clearing NQ data table Clearing NQ data table with jumper JP2 on Whenever changing denomination it is required to There are 2 jumpers located on the Machine Con- clear the NQ data table. The NQ data table keeps troller.
NRC 010 settings Removal of note guides • Loosen and remove six screws on each side of the cassett according to the illustration. ������� • Pull the reject box slightly backwards according to the illustration. ������� • Lift out the note guides as shown. �������...
NRC 010 settings • Push reject box back into place and tighten the six screws. ������� Note table Follow the table for note width and note length to see in which position to fit the note guides. Tables for adjustment �����������������������������...
Page 18
safety requirements External interconnection Interconnecting cables and cable assemblies used for external interconnection between parts of equipment or between components Chassis GND The machine chassis needs to be connected to GND due to EMC levels. The GND connection can be made either on one of the six fastening points on the bottom plate or with a separate cable from the connector on the sideplate.