Metso Neles RCI9H2 Installation Maintenance And Operating Instructions

Metso Neles RCI9H2 Installation Maintenance And Operating Instructions

Remore communication interface for vg9000h

Advertisement

RCI9H2
Remote Communication Interface
for VG9000H
Installation, Maintenance and
Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Neles RCI9H2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Metso Neles RCI9H2

  • Page 1 RCI9H2 Remote Communication Interface for VG9000H Installation, Maintenance and Operating Instructions...
  • Page 2: Table Of Contents

    These instructions provide information about the safe handling and operation of the converter. If you require additional assistance, please contact the manufacturer or manufacturer's representative. Addresses and phone numbers are printed on the back cover. See also www.metso.com/valves for the latest documentation. SAVE THESE INSTRUCTIONS! Subject to change without notice.
  • Page 3: General

    This manual incorporates Installation, Maintenance and VG9000H (Alarm and Test status). Operation Instructions for the Metso’s RCI9H2. RCI9H2 has two configuration switches. One switch is for to RCI9H2 is meant to be used together with Neles ValvGuard connecting RCI9H2 internal HART loop resistor (250 Ω) to...
  • Page 4: Recycling And Disposal

    7 RCI9H2 70 en HART: Data for application in connection with Ex-areas: Connection: Terminals 7-, 8+ (source) ATEX/IECEx: Ex II (1) G [Ex ia Ga] IIC Terminals 7-, 9+ (sink) cCSAus: Canada: [Ex ia] IIC Input current: Fixed at 11 mA, Class I, Division 1, source or sink mode Groups A, B, C, D...
  • Page 5: Installation

    7 RCI9H2 70 en INSTALLATION Single and multiple pair may be combined in a given network provided all current input devices associ- Mounting ated with multiple pairs of the same cable shall be located nominally at one end of the multi-pair cable. Open the two DIN rail retaining clips on the bottom of the Unshielded cable may be used if it is demonstrated device.
  • Page 6: Commissioning And Operation

    7 RCI9H2 70 en COMMISSIONING AND OPERATION DIP Switches Signal to VG The RCI9H2 has two DIP switches; switch 1 (S1) and switch 2 (S2). Switch 1 (HART loop resistor) Table 1 Switch selections Switch 2 (HART mode) Switch S1 HART loop resistor Mode / Teminals Alarm (red)
  • Page 7: Maintenance

    7 RCI9H2 70 en MAINTENANCE Pull the DIN rail retaining clips outwards using a flat screwdriver. If RCI9H2 unit becomes faulty, the complete unit needs to be replaced with a new unit. Take RCI9H2 off the DIN rail and replace with a new one.
  • Page 8: Ec Declaration Of Conformity

    Vantaa 7th January 2016 Ralf Liljestrand, Manager, Product safety and compliance Metso Flow Control Inc. Europe, Vanha Porvoontie 229, P.O. Box 304, FI-01301 Vantaa, Finland. Tel. +358 20 483 150. Fax +358 20 483 151 North America, 44 Bowditch Drive, P.O. Box 8044, Shrewsbury, M A 01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172 South America, Av.