Chattanooga Intelect Advanced Series User Manual

Chattanooga Intelect Advanced Series User Manual

!vacuum electrode module

Advertisement

Moving
Rehabilitation
Forward™
Vacuum Electrode Module
!
User Manual
Operation Instructions for:
2774 - Vacuum Electrode Module with
Therapy System Cart
2785 - Vacuum Electrode Module
DJO is an ISO 13485 Certified Company

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intelect Advanced Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chattanooga Intelect Advanced Series

  • Page 1 Moving Rehabilitation Forward™ Vacuum Electrode Module User Manual Operation Instructions for: 2774 - Vacuum Electrode Module with Therapy System Cart 2785 - Vacuum Electrode Module DJO is an ISO 13485 Certified Company...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Intelect Advanced Vacuum Electrode Module ® Foreword........... . 1 Electrotherapy .
  • Page 3: Foreword

    FOREWORD Intelect Advanced Vacuum Electrode Module ® This manual has been written for the owners of an Intelect Advanced Vacuum Electrode Module. It contains general information on the operation, precautionary practices and maintenance information. In order to maximize use, efficiency and the life of your system, please read this manual thoroughly and become familiar with the controls as well as the accessories before operating the system with the Vacuum.
  • Page 4: Electrotherapy

    ELECTROTHERAPY Intelect Advanced Vacuum Electrode Module ® PRECAUTIONARY INSTRUCTIONS The precautionary instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this equipment. The definition of these • Read, understand and practice the precautionary and operating symbols are as follows: instructions.
  • Page 5 ELECTROTHERAPY Intelect Advanced Vacuum Electrode Module ® Precautionary Instructions (continued) • This equipment generates, uses and can radiate radio frequency energy • Before administering any treatment to a patient, become acquainted with and, if not installed and used in accordance with the instructions, the operating procedures for each mode of treatment available, as well as the indications, contraindications, warnings and precautions.
  • Page 6 ELECTROTHERAPY Intelect Advanced Vacuum Electrode Module ® Precautionary Instructions (continued) • Stimulus delivered by the TENS waveforms of this device, • The safety of TENS waveforms for use during pregnancy or birth has not been established. in certain configurations, will deliver a charge of 25 •...
  • Page 7: Electrotherapy Indications, Contraindications And Adverse Effects

    ELECTROTHERAPY Intelect Advanced Vacuum Electrode Module ® Electrotherapy Indications, Contraindications and Adverse Effects Indications for VMS™, VMS™ Burst, Russian, TENS, • Powered muscle stimulators should not be used on patients with cardiac demand pacemakers. High Voltage Pulsed Current (HVPC), Interferential, and •...
  • Page 8: Nomenclature

    NOMENCLATURE Intelect Advanced Vacuum Electrode Module ® Intelect Advanced Vacuum Electrode Module 1. Exhaust/Overflow Hose (Routes to bottom of Therapy System Cart) 2. Vacuum Module to Intelect Advanced Therapy System Leads 3. Vacuum LED Indicators 4. Vacuum Mode Selector Button 5.
  • Page 9: Symbol Definitions

    NOMENCLATURE Intelect Advanced Vacuum Electrode Module ® Symbol Definitions Below are the definitions for all of the symbols used on the Intelect Advanced hardware and symbols used within the software. Study and learn these symbols before any operation system. Intelect Advanced Therapy System Symbols Intelect Advanced Optional Module and Accessory Symbols System Hardware Symbols...
  • Page 10: Specifications

    SPECIFICATIONS Intelect Advanced Vacuum Electrode Module ® Vacuum Electrode Module Specifications DIMENSIONS Width............22.7 cm (8.9375”) WIDTH Depth .
  • Page 11: System Setup

    SYSTEM SETUP Intelect Advanced Vacuum Electrode Module ® Intelect Advanced Vacuum Electrode Module Vacuum Electrode Module Setup The Intelect Vacuum Electrode Module is designed to function with the Remove the Intelect Advanced Therapy System Cart with Vacuum Electrode Module and all accessories from shipping cartons. Visually inspect for Intelect Advanced Therapy System only.
  • Page 12: Electrode And Patient Preparation

    ELECTRODE & PATIENT PREPARATION Intelect Advanced Vacuum Electrode Module ® Vacuum Electrode Instructions Select the prescribed Vacuum Electrode size and install one to the opposite end DJO Vacuum Electrodes are designed specifically for use with the Intelect of each Vacuum lead hose. Advanced Vacuum Electrode Module for optimum efficiency and performance of the Intelect Advanced Therapy System.
  • Page 13: Operation

    OPERATION Intelect Advanced Vacuum Electrode Module ® Vacuum Electrode Module Adjusting Vacuum Intensity Perform Electrode & Patient Preparation Use the following instructions in conjunction with the Intelect Advanced as described on page 10. User Manual, part number 27429, when setting waveform parameters. Adjust Vacuum Intensity by rotating the NOTE: Vacuum Intensity Knob from 1 to 10 on...
  • Page 14 OPERATION Intelect Advanced Vacuum Electrode Module ® Vacuum Electrode Module (continued) Setting up Waveform Parameters No waveform parameters or selections can be made with the Vacuum Module. Refer to the Intelect Advanced Therapy System User Manual, part number 27429, for all waveform selection and parameter setting instructions.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Intelect Advanced Vacuum Electrode Module ® General Information The Intelect Advanced Therapy Systems incorporate Error Messages and Warnings to inform the user of problems or potential problems with the system, modality or accessories. Refer to the Intelect Advanced Therapy System User Manual, part number 27429 for all Error Message Troubleshooting of the Intelect Advanced Therapy System.
  • Page 16: Replacement Accessories

    REPLACEMENT ACCESSORIES Intelect Advanced Vacuum Electrode Module ® General Information The following provides users of Intelect Advanced Therapy System with Vacuum Electrode Module, the necessary information to order the replacement accessories most commonly used with the system. This list of replacement accessories are designed for use with the Intelect Advanced Vacuum Electrode Module.
  • Page 17: Maintenance

    MAINTENANCE Intelect Advanced Vacuum Electrode Module ® Cleaning the Vacuum Module After draining is complete, reinstall Vacuum Module Cleaning Drain Tube to plug. With the system disconnected from the power source, clean the NOTE: vacuum module with a clean, lint free cloth moistened with water and mild antibacterial soap.
  • Page 18 MAINTENANCE Intelect Advanced Vacuum Electrode Module ® Service Flushing Lead Hoses and Reservoir Connect all four lead hoses to the Vacuum Module. Should the unit require service, warranty, or repair, please contact the selling dealer or your local DJO customer service. Submerse the other end of the lead hoses into a container filled with at WARRANTY...
  • Page 19: Warranty

    WARRANTY Intelect Advanced Vacuum Electrode Module ® DJO, LLC ("Company") warrants that the Intelect Advanced Vacuum Electrode Module ("Product") is free of defects in material and workmanship. This warranty shall remain in effect for two years (24 months) from the date of original consumer purchase. If this Product fails to function during the two year warranty period due to a defect in material or workmanship, Company or the selling dealer will repair or replace this Product without charge within a period of thirty (30) days from the date on which the Product is returned to the Company or the dealer.
  • Page 20 DJO is an ISO 13485 Certified Company DJO France SAS Centre Europeen de Fret 3 rue de Bethar 64990 Mouguerre, France T: + 33 (0) 5 59 52 86 90 F: + 33 (0) 5 59 52 86 91 djoglobal.eu/fr_FR ©...

Table of Contents