Page 1
SKW / SKF-2015-09-ENG Original document language: English Installation, operation and maintenance instructions for Flowrox Slurry Knife Gate valves SKW DN50 –600 (Wafer) and SKF DN80 –600 (Flanged) These instructions must be read carefully and understood prior to the installation, use, and servicing of this product.
Page 2
PRESENTED IN THIS MANUAL MAY BE OMITTED IN EVENT WHEN IT IS REQUIRED OR ALLOWED BY FLOWROX HAS TAKEN EVERY CARE IN THE PREPARATION OF THE CONTENT OF THIS MANUAL, BUT DOES NOT MAKE ANY REPRESENTATIONS, WARRANTIES OR GUARANTEES OR, EXPRESS OR IMPLIED, AS TO THE ACCURACY OR COMPLETENESS OF THIS MANUAL.
TABLE OF CONTENTS DIRECTIVE CONFORMANCE DECLARATIONS ..........4 General safety instructions ................ 5 INTRODUCTION ................6 Applications and purpose of use ..............6 2.1.1 Restrictions on use for SKW and SKF valves ..........6 2.1.2 Using the valve in explosive conditions ............6 General description .................
Conformance declarations for accessories (solenoid valve, limit switches etc.) and actuators are supplied separately in component documentation. Risk analysis responsible employee at Flowrox Oy is Jarmo Partanen. On behalf of Flowrox Oy In Lappeenranta, 1 September 2015...
2 INTRODUCTION 2.1 Applications and purpose of use Flowrox Slurry Knife Gate valves (SKW) and (SKF) are intended for industry medium and slurry applications. They are bi-directional and are installed between flat flanges to shut-off or open flow within instructed temperature and pressure limits.
2.2 General description 2.2.1 Principle of operation Flowrox SKW and SKF valves are built with a cast or welded body and feature a heavy-duty stainless steel gate as a standard structure. Removable ring sleeves on both sides of the gate provide a bi-directional bubble tight seal.
2.3 Technical data 2.3.1 Product identification Flowrox valve type plate is shown in Figure 5. 1. Valve type (see Table 5) 2. Serial number (year, order number, series size, individual valve number) 3. Customer tag number etc. 4. Nominal diameter, pressure class Figure 5.Valve type plate example.
When storing used valves, wash the valve and also the body cavities with fresh water and follow the steps above. For storage periods greater than 36 months, please contact Flowrox as the rubber parts need to be changed before use.
Flowrox gate valves have connections with DIN or ANSI bolt drillings as standard design, but other drillings are also available, such as BS, AS, JIS. Reserve enough space for safe installation and maintenance. See Appendix A for valve dimensions.
WAR N I NG When valve flushing is required, customers need to provide the plumbing. The valves are shipped with plugs installed in the flushing holes. Contact Flowrox office for process specific instructions. The concept of flushing is to ensure the valve does not jam due to accumulation of medium solids in the valve body.
Spare part name and quantity (example: Ring sleeve, 2 pieces) ● You can order the spare parts from Flowrox offices, distributors or agents. Contact information is available at http://www.flowrox.com It is recommended to keep the spare parts of Table 9 available at your factory warehouse.
WAR N I NG POULENE RHODORSIL III Flowrox gate valves have grease nipples on both sides of the valve body (Figure 12). Valves are lubricated when assembled - therefore first lubrication should not be required unless the valves have been in stock for a longer time. For dry material handling, lubrication might be limited or forbidden.