Signal Symbols; Warranty Conditions; Installation - Gemini 911 Installation And Use Manual

Narcotic gas and explosive gas wireless detector

Advertisement

8.0 - SIGNAL SYMBOLS

S Y M B O L
C O L O R
G r e e n
!
Ye l l o w
R e d
8.1 - YELLOW LED SIGNAL INDICATIONS
Y E L L O W
A C O U S T I C
L E D
A L E R T
C o n s e c u t i v e
N o n e
f l a s h i n g s
S h o r t b e e p
O n s t e a d y
e v e r y 5 m i n u t e s
O n s t e a d y
N o n e
9.0 -

WARRANTY CONDITIONS

This product is guaranteed to be free from defects in workmanship for a period
of 24 months from the date of installation reported on the present warranty, in
compliance with the1999/44/CE Warranty Directive (L.D. N° 24 -
02/02/2002).
Please fill-in entirely the guarantee certificate included in this manual and DO
NOT REMOVE the guarantee label affixed to the device.
The warranty will become void if labels are missing or torn, if the installation
certificate is not fully compiled or if the enclosed sale document is missing.
The warranty is valid exclusively at authorized Gemini Technologies centers.
The manufacturer declines any responsability for eventual malfunctions of the
detector or any damage to the vehicle electrical system due to improper
installation, use or tampering.
PAGE 06 - USER MANUAL
D E S C R I P T I O N
S u p p l y v o l t a g e p r e s e n t
Signaling of specific functional conditions
(see table 8.1)
Power ON - alarm ON
D E T E C TO R
C O N D I T I O N
S t a r t i n g a n d w a r m i n g u p
Out of order due to exhaustion of
probe (after 11,000 working hrs)
Faulty
INSTALLER MANUAL

10.0 - INSTALLATION

The 911 detector is intended for a permanent installation.
The device must be positioned at about 20-40 cm from the vehicle cabin floor
to be protected.
The detector must be installed at least 1-1,5m away from any air supply
register; if there is an air intake vent, install the detector near it.
10.1 -FITTING OF DETECTOR
!
Remove the detector cover by prying lightly with a screwdriver inserted in
the release slot on the right side of the casing.
!
The two screw holes (FF) can be used to mount the detector to a wall or
onto a base (fig.1); the electronic card must first be removed by unscrewing
the screw on the bottom right corner. (see par.
10.2 - ELECTRICAL CONNECTIONS
!
The pre-drilled holes (FC) are used to run the power wiring (see par.
!
Connect the wires that supply 12 or 24V to the terminal block M2 (see par.
12)
; depress the supply terminal block to introduce the cables which must
have a section comprised between 0,5 and 1,5 mm².
!
Remove 9mm of sleeve from the cable before inserting it in the terminal
block; release the push-button and pull on the cable to make sure it is well
secured.
!
The auxiliary devices conductors intended to manage the alarm must be
connected to terminal block M1; the maximum rating of the relay contacts is
2A at 28Vdc (refer to par. 13). To actuate devices having a higher
absorption rate, an auxiliary relay must be provided.
10.3 - MOUNTING DIAGRAM
FC
FR
FF
Figure 1
FC
13
).
FF -
Pre-drilled mounting holes, use the
ones to the far ends.
FC -
Pre-drilled holes to run the cables,
FC
use the ones on the left for the power
cable.
FR -
Power supply cable holder.
INSTALLER MANUAL - PAGE 07