WARNINGS AND CAUTIONS • Read and understand all instructions. Follow all warnings and instructions marked on the product. • Do not use this product near water - e.g., near a tub, wash basin, kitchen sink or laundry tub, in a wet basement, or near a swimming pool.
Page 3
INTRODUCTION The LEVITON Model 83A00 Power Hub is a general purpose 12VDC power supply. It is designed to provide power to several LEVITON products, including the LEVITON Access Control Card Readers with electric or magnetic locks, Omni Consoles, OmniTouch 5.7 Touchscreens, and many other devices.
Power Hub(s) must be grounded together to prevent any current from flowing through the RS-485 data bus (connections A and B). If not grounded properly, damage could occur to the LEVITON controller, LEVITON Power Hub, Access Control Card Readers, Omni Consoles, and/or OmniTouch Touchscreens.
Page 5
Connecting Devices of the Same Communications Type For example, if all connected devices that communicate with the LEVITON controller consist of 75A00-1 Access Control Readers (which communicate on a serial port), then the communications path for the first row (DEVICE 1 –...
Page 6
FOR DEVICES OF THE SAME COMMUNICATIONS TYPE, SWITCH SHOULD BE IN THE "CONNECT" POSITION. Figure 3 Connecting Devices of Different Communications Types If a combination of 75A00-1 Access Control Readers and Consoles and/or Touchscreens are connected, then the communications path for the first row must be separated from the second row. Switch “SW1” must be in the “DISCONNECT”...
Page 7
The 75A00-1 requires 4 wires for operation (2 for power and 2 for communications). The maximum distance between the 75A00-1 and the LEVITON 83A00 Power Hub is based on two factors: 1) the current draw of the connected door lock device, and 2) the wire gauge/type used. To maintain proper operation of the 75A00-1 and the connected door lock device, do not exceed the "Maximum Cable Length"...
Page 8
Connect the supplied 4-conductor reversed modular cable (gray cable) between one of the modular connectors (J301 or J302) on the Power Hub and a serial port (J2 – J5) on the LEVITON controller (See – Figure 6). The serial port that is used for LEVITON Access Control must be configured for RS-485 communications. The corresponding interface jumper (JP2-JP5) must be in the "485"...
Page 9
Figure 6 Connecting Additional LEVITON Power Hubs When connecting more than 8 Model 75A00-1 Access Control Card Readers to an LEVITON OmniPro II or LEVITON Lumina Pro controller, if additional power is needed to control the required Access Control Readers and connected locks, or if there are long distances between Access Control Readers and the LEVITON controller, multiple LEVITON Power Hubs may be used.
Page 10
Black (straight-through) Cable Gray (reversed) Cable CONTROLLER MODEL 83A00 MODEL 83A00 12VDC POWER HUB 12VDC POWER HUB WHEN A SERIAL INTERFACE IS CONFIGURED FOR ACCESS CONTROL, THE CORRESPONDING INTERFACE JUMPER (JP1-JP5) MUST BE IN THE "485" POSITION. FOR EXAMPLE: JP2 MUST BE SET TO "458" WHEN SERIAL INTERFACE 2 (J2) IS USED FOR ACCESS CONTROL.
Page 11
If Omni Consoles or OmniTouch Touchscreens are being connected to the Power Hub, connect the terminals labeled “A” and “B” on the LEVITON Power Hub under the section marked “CONTROLLER”, to the “A” and “B” terminals on the LEVITON controller.
Page 12
“A” and “B” under the section marked “CONSOLE” on the LEVITON controller if a) “SW1” is in the “CONNECT” position, AND b) Either modular connector “J301” or “J302” is connected to a serial port (J1 – J5) on the LEVITON controller.
When the backup batteries connected to the Power Hub become depleted, there are terminals on the Power Hub that are used to send a signal to the LEVITON controller to alert you of the low battery condition. To take advantage of this feature, you must have an extra pair of wire between the Power Hub and the LEVITON controller, and an available zone on the LEVITON controller.
SPECIFICATIONS Operating 32 - 120 degrees F (0 - 49 degrees C) Ranges: 10 - 85 % relative humidity, non-condensing Power Pack: Output 19VDC, 4.74 Amps, Max 90W Input 100-240VAC, 1.5A Amps, 50/60Hz Output Power: Nominal Voltage 12VDC Maximum Current 5A Batteries: Sealed, Rechargeable, 12 Volts, 4 - 8 Amp-Hours, each Low Voltage Cut Out:...
Page 15
LEVITON LIMITED WARRANTY Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from defects in material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II a nd Lumina Pro: t hree (3) years from installation or 42 months from manufacture date.•OmniLT, O mniIIe, a ndLumina:two (2) years from installation or 30 months from manufacture date.•Thermostats, A ccessories:two (2) years from installation or...