3) UV FRAMES Setting
Users can set the frame rate of UV video to 1, 5, 10, 15, or 30 frames. Lower frame number
has longer exposure time, which makes it easier for the device to detect fine lights as well but its
reaction time becomes slower. With higher frame number, you will have faster reaction time but
its sensitivity will drop.
4) MAX LEVEL HOLD TIME
Users can set how long they want to display the max detect level. It can be set from 1 to 5
seconds.
5) ESD CALIBRATION
This function is to collect the photon count info by ESD level to assume ESD voltage. This
ESD calibration is performed in three different levels: 1KV, 3KV, and 6KV.