NO OPERATION OF MD
When no sound output in the CD function, you can not listen to music reading data
from a CD disc if the pickup module in MD doesn't work. This step is for checking the
LASER FOCUSING ACTUATOR.
4-5. LASER FOCUSING ACTUATOR
4-5-1. Solution
Please check and replace IC301, IC302 on MAIN board.
4-5-2. How to troubleshoot (Countermeasure)
The focusing actuator makes the laser beam keep a regular interval with the surface of a CD disc.
1) Check the FOD signal from Pin13 of IC302.
If no signal, check 3.3 V(RF) and X301.
2) Check F- & F+ from IC301 to CN301 for driving the focusing actuator.
If no signal, check +1.8 V and +5 V for IC301.
3) Check if the FFC cable is solidly connected between CN301 and MD.
4) Check the MD.
If the pickup module has any trouble, it can not move the laser beam on the top or bottom side.
Please check the function after changing another MD.
4-5-3. Service hint (Any picture / Remark)
< Waveform of TR±
for driving FOCUSING actuator >
ONE POINT REPAIR GUIDE
3-10