15. MAINTENANCE

15.1 General notes

In order to ensure optimal availability of the unit, a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals.
IMPORTANT
ALL MAINTENANCE WORK AND REPLACEMENTS MUST BE CARRIED OUT BY SKILLED QUALIFIED PER-
SONNEL.
Before carrying out any operation inside the indoor unit, disconnect the power and close the gas cock upstream.
Otherwise there may be a danger of explosion, electric shock, suffocation or poisoning.
Do not touch the refrigerant circuit pipes and the internal parts (pump, safety valve, etc.) during and immediately after switching off the unit as they can be very hot or
very cold, causing scucking or burning or freezing. To avoid injury, allow sufficient time for the temperature of the pipes to drop to normal values and wear protective
gloves.
Before carrying out any maintenance or repair work, always disconnect the power supply to the unit and to all electrical loads (pumps, valves, electric boosters, elec-
trical resistors, etc.).
Some electrical components may be very hot.
Due to the risk of high residual voltage, after having disconnected the power supply to the outdoor unit, wait at least 10 minutes before touching live parts.
The compressor oil heater can work even if the compressor is stopped.
Make sure not to touch powered electrical cables.
Do not wash the unit. This may cause electric shock or fire.
When the service panels are removed, live parts could easily be touched by mistake.
Never leave the unit unattended during installation or maintenance when the service panel has been removed.
It is not allowed to tamper with or modify any component, nor the settings of the intervention values of the protection devices installed in the unit.
Do not pull, disconnect, twist the electric cables coming from the unit even if disconnected from the power supply.
It is forbidden to leave containers of inflammable substances near the unit.
Do not touch the appliance with bare feet or with wet or moist parts of the body.
The checks described must be performed at least once a year by qualified personnel.
Electrical cabinet
Carry out a thorough visual inspection of the components of the electrical panel to check for damaged or incorrectly connected components or cables (check the
tightness of the terminal screws).
Residual Risks
The machines has been designed with a view to reducing the risks to persons and the environment in which it is installed, to the minimum. To eliminate residual risks,
it is therefore advisable to become as familiar as possible with the machine in order to avoid accidents that could cause injuries to persons and/or damage to property.
a. Access to the unit
Only qualified persons who are familiar with this type of machine and who are equipped with the necessary safety protections (footwear, gloves, helmet, etc.) may
be allowed to access the machine. Moreover, in order to operate, these persons must have been authorized by the owner of the machine and be recognized by the
actual Manufacturer.
b. Elements of risk
The machine has been designed and built so as not to create any condition of risk. However, residual risks are impossible to eliminate during the designing phase and
are therefore listed in the following table along with the instructions about how to neutralize them.
Indoor unit residual risks
Part in question
Refrigerant
and hydraulic pipes
Refrigerant pipes, plate heat exchanger.
Refrigerant pipes
Electrical cables, metal parts
Outdoor unit residual risks
Part in question
Compressor and delivery pipe
Discharg pipes and coil
Refrigerant pipes
Electrical cables, metal parts
Heat exchange coils
Fans
MAINTENANCE
Residue hazard
Burns
Explosion
Ice burns
Electrocution, serious burns
Residue hazard
Burns
Contact with the pipes and/or compressor
Explosion
Ice burns
Electrocution, serious burns
Defective cable insulation, live metal parts
Cuts
Cuts
Cod. 3541T090 - Rev. 00 - 06/2019
Mode
Contact with the pipes
Turn off the machine, check the high pressure switch and
Excessive pressure
Leaking refrigerant
Defective cable insulation,
live metal parts
Mode
Excessive pressure
Leaking refrigerant
Adequate electrical protection (correctly ground the unit)
Contact
Contact with the skin
Do not push the hands or objects through the fan grille
Precautions
Avoid contact by wearing
protective gloves
safety valve, the fans and condenser
Do not pull on the pipes
Adequate electrical protection
(correctly ground the unit)
Precautions
Avoid contact by wearing
protective gloves
Turn off the machine,
check the high pressure switch
and safety valve,
the fans and condenser
Do not pull on the pipes
Wear protective gloves
EN
87