16 | ACS 751/651 | Scales
4.3

Entering the debug mode

1. Connect the power cable to the mains supply.
2. Switch on the power supply.
3. Press the C key and power on the ACS 751/651.
4. Enter the password 33284.
"
The "Debug Mode" menu is displayed.
4.4

Overview of actuators

i
See chapter 15 for the hydraulic circuit diagram.
Actuator name Description
CTRL
Entry to internal tank
CX
Compressor
CXOL
Compressor oil return
FA
Fan
HL
Connection from LP to HP
HPS
High pressure switch
IN
Entry to liquefier
LP
Entry through LP hose
OD
Oil drain
OI
Oil recharge
PRIN
Passage for clearing
PTA/PSA
Pressure sensor for accumulator
PTT/PST
Pressure sensor for tank
PTV/PSV
Pressure sensor for vacuuming
PU
Air purge on refrigerant cylinder
RE
Connection between internal refrig-
erant cylinder and manifold
UV
UV dye recharge
VC
Vacuum pump
VISO
Connection between vacu-
um pump and manifold
|
1 689 975 223
2013-10-21
5.

Scales

5.1

Calibration of scales

5.1.1

Fresh Oil / used oil / UV dye scales

1. Open the service hatch on the front panel.
2. In the main menu, select "ACS Settings" and press E.
? The ACS Settings menu is displayed.
3. Select "Calibration".
4. Select "Balance Calibration".
5. Enter the password 227.
? The following screen is displayed.
6. Select any of the sensors - fresh oil, used oil or UV dye.
? The following screen is displayed.
7. Detach the bottle from the connector.
8. Select "Remove Bottle".
9. Attach the calibrating weight to connector of the oil
/ UV dye sensors.