hilscher NANL-B500G-RE User Manual

hilscher NANL-B500G-RE User Manual

Netanalyzer device
Hide thumbs Also See for NANL-B500G-RE:
Table of Contents

Advertisement

Quick Links

User manual
netANALYZER device NANL-B500G-RE
Installation, operation and hardware description
Hilscher Gesellschaft für Systemautomation mbH
www.hilscher.com
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NANL-B500G-RE and is the answer not in the manual?

Questions and answers

Summary of Contents for hilscher NANL-B500G-RE

  • Page 1 User manual netANALYZER device NANL-B500G-RE Installation, operation and hardware description Hilscher Gesellschaft für Systemautomation mbH www.hilscher.com DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 2: Table Of Contents

     16 2.4.4 Damage of externally attached hardware ............ 16 2.4.5 Assignment of wrong IP addresses, malfunction (NANL-B500G-RE) ....  17 2.4.6 Power drop during write and delete accesses in the file system .... 17 2.4.7 Exceeding the maximum number of permitted write and delete accesses .. 17 Labeling of safety messages.................. 18...
  • Page 3 Auto-crossover and port-switching................. 62 How to update the NANL-B500G-RE firmware .............. 63 7.9.1 How to update the NANL-B500G-RE firmware using a web browser.....  63 7.9.2 How to update the NANL-B500G-RE firmware via FTP .........  66 7.10 Temperature control of the fan (NANL- B500G-RE) ............ 69 Hardware properties ......................
  • Page 4 12.1 Analyzer device NANL-B500G-RE................. 83 13 Annex ............................ 86 13.1 Disposal of waste electronic equipment................. 86 Glossary.......................... 89 Contacts.......................... 90 netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 5: Introduction

    This user manual contains descriptions for installation and operation of the netANALYZER hardware for netANALYZER portable device with Gigabit Ethernet PC interface of the device type NANL-B500G-RE (stand-alone device), for real-time Ethernet and all 10/100BASE-T Ethernet networks. For the descriptions of the software installation, see installation...
  • Page 6: List Of Revisions

    Section Overview installation update [} page 28] revised. Section Set the time for the autonomous operating mode [} page 42] revised. Section How to update the NANL-B500G-RE firmware using a web browser [} page 63] added. Section Temperature control of the fan (NANL- B500G-RE) [} page 69] revised.
  • Page 7: Conventions In This Manual

    Intermediate result Final result Safety messages The labeling of safety messages is explained in the chapter Safety. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 8: Product Dvd And Documentation

    NANL-B500G-RE image version <no data name> 1.10.x.x <no path> Table 3: Installed netANALYZER files (firmware, driver, toolkit) netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 9: Legal Notes

    NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 10 Introduction 10/90 Liability disclaimer The hardware and/or software was created and tested by Hilscher Gesellschaft für Systemautomation mbH with utmost care and is made available as is. No warranty can be assumed for the performance or flawlessness of the hardware and/or software under all application conditions and scenarios and the work results achieved by the user when using the hardware and/or software.
  • Page 11 The customer hereby expressly acknowledges that this document contains trade secrets, information protected by copyright and other patent and ownership privileges as well as any related rights of Hilscher Gesellschaft für Systemautomation mbH. The customer agrees to treat as confidential all of the information made available to customer by Hilscher Gesellschaft für...
  • Page 12: Registered Trademarks

    PCI™ is a trademark of the Peripheral Component Interconnect Special Interest Group (PCI-SIG). All other mentioned trademarks are property of their respective legal owners. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 13: Licenses

    DOC150205UMXXDE). "Autonomous operating mode" and "Snapshot mode" Note: The analyzer device NANL-B500G-RE can be used both in the "Interactive operating mode" with a connected PC, as well as in the "Autonomous operating mode" without a PC. As a prerequisite to use the "Autonomous operating mode", a license (netANALYZER autonomous operating mode LIC/NANL/SA) is required.
  • Page 14: Safety

    NANL-B500G-RE and all 10/100BASE-T Ethernet networks Table 5: netANALYZER device If the analyzer device NANL-B500G-RE is used outside the range of application described in this user manual or the associated documentation, an error free function of the device cannot be guaranteed.
  • Page 15: Property Damage

    The data on the permissible signaling voltage of the devices described in this manual you find in the section Power supply and host interface. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 16: Exceeding The Permissible Current Consumption At The External I/O Interface

    I/O interface must not be exceeded. · The netX chip and other components of the NANL-B500G-RE device can be damaged if the current consumption at the I/O signal pins of the external I/O interface exceeds the maximum permitted values!
  • Page 17: Assignment Of Wrong Ip Addresses, Malfunction (Nanl-B500G-Re)

    2.4.5 Assignment of wrong IP addresses, malfunction (NANL-B500G-RE) The analyzer device NANL-B500G-RE must not be inserted via a switch or hub directly into a corporate network with other devices, as long as the analyzer device is operating in DHCP server operation mode. Otherwise, it may lead to wrong assignment of IP addresses and malfunction.
  • Page 18: Labeling Of Safety Messages

    Cor.:2015); German version EN 62368-1: 2014 + AC: 2015 [S3] EN 61340-5-1 and EN 61340-5-2 as well as IEC 61340-5-1 and IEC 61340-5-2 netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 19: Description

    Description 19/90 3 Description With the analyzer device NANL-B500G-RE you can record the performance and functions of individual systems or system components of bus systems that comply with the Ethernet II IEEE 802.3 specification. The NANL-B500G-RE analyzer device described in this user manual operates as a passive Ethernet analyzer in Real-Time Ethernet systems.
  • Page 20: Recording And Analyzing Data Traffic

    B500G-RE analyzer device alternatively is performed with start and stop via the REC key, without PC software. Test Access Points (TAP) Two TAPs are integrated into the NANL-B500G-RE analyzer device so that two communication channels are ready for use. Figure 2: Example representation physical TAP netANALYZER device NANL-B500G-RE | Installation, operation and hardware description ©...
  • Page 21: Figure 3: Typical Analyzer Application With The Capturing Of The Ethernet Data Transfer And Io Events

    In addition, events from up to four digital inputs can be recorded. At the four digital inputs, the input signals generate a special pseudo Ethernet frame in the NANL-B500G-RE analyzer device. This frame is generated by the analyzer device and evaluated accordingly by the analysis software.
  • Page 22: Interactive And Autonomous Operating Mode

    22/90 Interactive and Autonomous operating mode Figure 4: Interactive and Autonomous operating mode Interactive operating mode In the "Interactive operating mode" the NANL-B500G-RE device is connected to a PC. Autonomous operating mode The NANL-B500G-RE device allows you (starting with the netANALYZER firmware image version 1.2.0.0) to additionally use the "Autonomous...
  • Page 23: System Requirements

    The maximum permitted cable length for the 24V power supply is 3 meters. · Power supply unit for NANL-B500G-RE device: 24V dc/ 1.3A Note: The power supply supplied with the NANL-B500G-RE device (for standard applications) is designed as follows: 24V DC / 1.25A (1.8M KAB).
  • Page 24: Power Supply And Host Interface

    I/O interface of the analyzer device. Note: If the power supply unit delivered with the NANL-B500G-RE device (dc 24V / 1.25 A) is used, at 500 mA at the external IO interface of the NANL-B500G-RE device the current limiter is turned on. To avoid a reset of the analyzer device, use for this special case a more powerful power supply (24 V DC / 1.3 A).
  • Page 25: Requirements Nanl-B500G-Re (Autonomous Operating Mode)

    MByte memory capacity The USB memory device can be an USB stick or an USB hard disk. The USB socket on the NANL-B500G-RE device supplies a maximum of 500 mA, sufficient to connect an USB stick. If an USB hard disk with higher power consumption is connected, a separate power supply is required.
  • Page 26: Getting Started

    Important! The color of both LEDs on the Gigabit RJ45 Ethernet socket on the reverse B500G-RE data save side of the analyzer device NANL-B500G-RE must be green! If the right LED lights up in without loss to the PC orange, the transfer rate to the PC is less than 1 Gb/s, by consequence insufficient bandwidth may occur.
  • Page 27: Overview Installation

    Insert the analyzer device NANL-B500G-RE into the communication path to be analyzed. Table 12: Overview installation netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 28: Overview Installation Update

    Copy the firmware update file from the product DVD into the netANALYZER FTP server directory. Table 13: Overview how to update the installation netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 29: Property Damage Messages

    Exceeding the permissible current consumption at the external I/O interface Device destruction! The netX chip, as well as further components of the NANL-B500G-RE device, can be damaged, if the current consumption at the I/O signal pins of the external IO interface pins exceeds the maximum permitted values! Ø...
  • Page 30: Damage Of Externally Attached Hardware

    IP addresses to other devices. This may happen also to devices which are not concerned by the netANALYZER measurements. Ø In order to connect the analyzer device NANL-B500G-RE to any network ensure that DHCP server operation mode is disabled.
  • Page 31: Power Drop During Write And Delete Accesses In The File System

    Ø Make sure, that the power supply of the device does not drop during write and delete accesses in the file system (firmware update, configuration download etc.). netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 32: Configure Ip Address

    The NANL-B500G-RE device can operate in three different modes: Static IP address (manual assignment) · A fixed IP address is assigned to the analyzer device NANL-B500G-RE. The user must manually assign the IP address designated. DHCP client mode (external DHCP server required) ·...
  • Page 33 NANL-B500G-RE using the Ethernet Device Configuration program. In Ethernet Device Configuration, to find the NANL-B500G-RE device, you must enable the NetIdentV2 protocol. For details refer to the operating instruction manual Ethernet Device Configuration, Address setting for Ethernet capable Hilscher devices.
  • Page 34: Device Drawings

    Gigabit Ethernet RJ45 socket to the PC (1 Port with 1 Gb/s) USB socket (Type A, USB 2.0, 4-pin) Table 14: Explanations to the front side and reverse side NANL-B500G-RE netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019...
  • Page 35: Commissioning

    Commissioning 35/90 7 Commissioning In order to install and commission the NANL-B500G-RE device, you must proceed as described in the following sections. For installation and operation of the netANALYZER device check any notes in the overview in chapter Getting started [} page 26].
  • Page 36: Netanalyzer Configuration Page

    Commissioning 36/90 netANALYZER Configuration page With a web browser you can open the configuration page of the analyzer device NANL-B500G-RE. On this page you can make settings: the time for autonomous mode, · · the behaviour of the fan, ·...
  • Page 37 Commissioning 37/90 Figure 8: netANALYZER configuration page netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 38: Interactive Operating Mode, Connection To Pc

    Step 1: Safety precautions  Device Destruction Ø The voltage applied at the NANL-B500G-RE device must not exceed 30 V, otherwise the device may be destroyed. Ø At the I/O signal pins of the External IO interface use exclusively 3.3 V or 24 V signaling voltage.
  • Page 39: Autonomous Operating Mode, General Conditions And Requirements

    Capturing snapshots (snapshot mode) [} page 51]. Important: If the power supply of the NANL-B500G-RE is expected to fail during capturing, the USB memory device can be used with an ext4 file system to prevent data loss. For further information, see section Notes for installation and operation [} page 26].
  • Page 40: Pcap Files (File Name And Size)

    The USB memory device can be an USB stick or an USB hard disk. The USB socket on the NANL-B500G-RE device supplies a maximum of 500 mA, sufficient to connect an USB stick. If an USB hard disk with higher power consumption is connected, a separate power supply is required.
  • Page 41: Default Settings For The Behavior Of The Gpio Signals In "Live Dump Mode

    50 MByte per second at maximum network load. If the power supply of the NANL-B500G-RE is expected to fail during capturing, the USB memory device can be used with an ext4 file system to prevent data loss. For further information, see section Notes for installation and operation [} page 26].
  • Page 42: Set The Time For The Autonomous Operating Mode

    Set the time for the autonomous operating mode The clock time can be set in the analyzer device NANL-B500G-RE via a web browser or via netANALYZER Scope. Note: When setting the clock time using the netANALYZER configuration web page, the analyzer device is restarted.
  • Page 43: Figure 9: Website Netanalyzer Configuration

    RE and are then used as the basis for the time stamp for each recorded frame. ð The device is restarted. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 44: Estimate Required Usb Memory Capacity For Snapshot Mode Theoretically

    Figure 10: Schematic representation of the reserve capacity of the USB memory device with a maximum number of snapshots = "4 netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 45 .nsprj snapshot files. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 46: Set Maximum Number Of Snapshots For Autonomous Operating Mode

    To set the maximum number of snapshots from a web browser, follow the steps below. Ø Enter the IP address of the analyzer device NANL-B500G-RE (e.g. 192.168.1.1.) into the address line of the browser. Ê The web page netANALYZER configuration appears.
  • Page 47: Figure 11: Website Netanalyzer Configuration

    Commissioning 47/90 Figure 11: Website netANALYZER configuration netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 48: Starting Or Stopping Nanl-B500G-Re In The Autonomous Operating Mode

    Ø Click Apply changes and restart device. ð The set value is stored in the analyzer device NANL-B500G-RE and defines the maximum number of snapshots that are stored on the USB memory device in the autonomous mode in snapshot mode.
  • Page 49: Autonomous Operating Mode, Capturing On Usb Memory Device

    7.5.1 Full capturing process (Live-Dump-Mode) Proceed as follows if you want to use the analyzer device NANL-B500G-RE in the Autonomous operating mode in Live dump mode with an USB memroy device and want to record data during the entire time span of an...
  • Page 50 PC. Ø Download .pcap files and open them in Wireshark or import them to netANALYZER-Scope. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 51: Capturing Snapshots (Snapshot Mode)

    7.5.2 Capturing snapshots (snapshot mode) Proceed as follows if you want to use the analyzer device NANL-B500G-RE in the autonomous operating mode in Snapshot mode with an USB memory device and only want to capture data from certain time windows via defined...
  • Page 52 Ê Each time a trigger criterion is met, a snapshot is stored to the USB memory device. Note: The internal memory of the analyzer device NANL-B500G-RE can buffer a maximum of 300 MB of Ethernet frame data, so that this maximum past events depth is available for snapshots. Depending on the network load, this results in the maximum detectable time period.
  • Page 53: Displaying Lost Frames In Wireshark

    53/90 7.5.3 Displaying lost frames in Wireshark If the NANL-B500G-RE analyzer device uses very high transfer rates for data transfer via Ethernet during autonomous operation and the write rate to the USB memory device increases accordingly, Ethernet frame losses occur when storing on the USB memory device, i.e. frames are discarded and no complete capturing of the transferred analysis data takes place.
  • Page 54 If necessary, use an external USB hard disk, since you can achieve higher writing rates in comparison to an USB stick. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 55: Inserting Netanalyzer Hardware Into The Communication Link

    Inserting netANALYZER hardware into the communication link Important: The analyzer device NANL-B500G-RE must not be inserted via a switch or hub directly into a corporate network with other devices, as long as the analyzer device is operating in DHCP server operation mode.
  • Page 56: Application Case 1

    Capturing and analyzing the communication between two devices Ø To capture the communication between two Ethernet devices, connect the analyzer device NANL-B500G-RE via Ethernet cable (as shown in the figure). Ø Connect both Ethernet cable only in TAP A (or in TAP B).
  • Page 57: Application Case 3

    Ethernet frames. · Ø To capture the communication of two channels, connect the analyzer device NANL-B500G-RE via Ethernet cable (as shown in the figure). Figure 14: Application case 2 netANALYZER device NANL-B500G-RE | Installation, operation and hardware description ©...
  • Page 58: Application Case 4

    Ethernet frames. Ø To capture the communication of two channels, connect the analyzer device NANL-B500G-RE via Ethernet cable (as shown in the figure). Figure 15: Application case 3 netANALYZER device NANL-B500G-RE | Installation, operation and hardware description ©...
  • Page 59 NANL-B500G-RE device! · To operate the NANL-B500G-RE device, take a maximum of 1 mA (at 3.3V) or 600 mA (at 24V) current at the I/O signal pins on the external I/ O interface. Otherwise the netX chip and other components may be damaged.
  • Page 60: Figure 16: Application Case 4 - Recording Of The Runtime In The Device

    Ø To capture the communication of two channels, connect the analyzer device NANL-B500G-RE via Ethernet cable (as shown in the figure). The figure also shows schematically how a digital output signal from the device is connected to the digital input of the analyzer device NANL- B500G-RE.
  • Page 61: Data Load Limitation

    3. Only capture on one TAP, then you can capture 100% load on that TAP netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 62: Auto-Crossover And Port-Switching

    In the records for the second test run compared with the first test run, modified port numbers can be found. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 63: How To Update The Nanl-B500G-Re Firmware

    How to update the NANL-B500G-RE firmware via FTP [} page 66]. · 7.9.1 How to update the NANL-B500G-RE firmware using a web browser Note: The IP address of the analyzer device NANL-B500G-RE must be configured according to section Configure IP address [} page 32].
  • Page 64: Figure 19: Ethernet Device Configuration - Nanl-B500G-Re Found (Example)

    Ê Your analyzer device NANL-B500G-RE is displayed. Figure 19: Ethernet Device Configuration - NANL-B500G-RE found (Example) Ø Read the IP address of the NANL-B500G-RE device whose firmware you want to update. For the example shown in the figure above, the IP address is 192.168.1.1.
  • Page 65 F5 key (depends on your web browser). Ø Check the version displayed next to netANALYZER image version. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 66: How To Update The Nanl-B500G-Re Firmware Via Ftp

    Ê Your analyzer device NANL-B500G-RE is displayed. Figure 20: Ethernet Device Configuration - NANL-B500G-RE found (Example) Ø Obtain the IP address of your NANL-B500G-RE device the firmware of which you want to update. For the example shown in the figure above the obtained IP address is 192.168.1.1.
  • Page 67: Figure 21: Ftp Server Log On Screen

    Figure 21: FTP server Log On Screen Ê The netANALYZER FTP server directory opens. Ø Copy the incremental firmware update file nanl-b500g-re.update to the netANALYZER FTP server directory. Ê The firmware update file can be found on the product DVD in the directory NANL-B500G-RE firmware update.
  • Page 68: Figure 23: Netanalyzer Ftp Server Directory Containing The Firmware Update File

    Ø There may exist a file update.log from a previous update process, the log file can be ignored. Ø Power off your NANL-B500G-RE device. Ø Power on your NANL-B500G-RE device and wait until the device is fully operational. Important: Wait until the LEDs will stay in state "SYS LED = green, STA0 LED = red, STA1 LED = off"...
  • Page 69: Temperature Control Of The Fan (Nanl- B500G-Re)

    Table 17: Threshold for the temperature control of the fan To set the temperature threshold using a web browser, perform the following steps. Ø Enter the IP address of the analyzer device NANL-B500G-RE (e.g. 192.168.1.1.) in the address line of the browser. Ê The web page netANALYZER configuration appears.
  • Page 70: Hardware Properties

    Ethernet or transparent mode in the user interface, refer to the operating instruction manual netANALYZER software, Data recording and analysis. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 71: Timestamp

    Thereby the preamble and SFD are not interpreted. Accuracy of the time stamping Time stamps on port 0 and port 1 on the NANL-B500G-RE device can have an offset of up to 40 ns. After a settling time of approx. 100 ms from reception of the first frame on a port, the offset on this port is max.
  • Page 72: Transparent Mode

    Figure 26: Ethernet frame in Wireshark in the Ethernet Mode Figure 27: Ethernet frame in Wireshark in the Transparent Mode netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 73: Troubleshooting

    Ø Check that the power supply of the device is connected to the mains voltage. Host connecting interference (NANL-B500G-RE) The Ethernet connection from the analyzer device NANL-B500G-RE device to the PC is a saved connection without loss. Transmission errors on the host Gigabit interface cable (such as EMC interference or bad connections) do not cause any data loss.
  • Page 74 SYS, STA0, STA1, I/O, LINK and RX (Front side) [} page 75]. If the power supply of the NANL-B500G-RE is expected to fail during · capturing, the USB memory device can be used with an ext4 file system to prevent data loss.
  • Page 75: Leds

    Capturing process is inactive, with or without USB memory device connected or USB memory device is not compatible or defective. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 76 Autonomous operating mode only: Faulty Ethernet frames detected. orange Flashing cyclic at Autonomous mode only: date/time not set, check when USB memory 1 Hz device is connected and when NANL-B500G-RE device is ready for operation. Single Flash Autonomous operating mode only: FIFO overflow change A buffer overflow occurred and consequently Ethernet frames were discarded.
  • Page 77: Table 18: Leds Nanl-B500G-Re (Front Side), Interactive Operating Mode And Autonomous Operating Mode

    LEDs 77/90 Color State Meaning Front side NANL-B500G-RE - RJ45 Ethernet sockets Ch0 and Ch1, TAP A and TAP B LINK / A connection to the Ethernet exists green RJ45 Ch0 The device has no connection to the Ethernet to Ch3...
  • Page 78: Link-Act And Link-1000/Link100 (Reverse Side)

    Color State Meaning Reverse side NANL-B500G-RE - Gigabit Ethernet RJ45 socket to the PC (1 port with 1 Gb/s) LED left side LINK- From the NANL-B500G-RE device to the PC an Ethernet connection is green ACT / established.
  • Page 79: Connectors And Interfaces

    11 Connectors and interfaces 11.1 Power Supply NANL-B500G-RE The analyzer device NANL-B500G-RE can be operated by a DC power supply from 18V to 30V. The connectors for the power supply are on the reverse side of the analyzer device. The power consumption is 31.2 W.
  • Page 80: Ethernet Interface

    100 m Reception rate 10 MBit/s / 100 MBit/s Table 22: Data of the Ethernet connection netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 81: External Io Interface

    24 V signaling voltage. Higher signaling voltages lead to severe damage to the NANL-B500G-RE device! Ø To operate the NANL-B500G-RE device, at the I/O signal pins of the external I/O interface, take a maximum of 1 mA (at 3.3V) or 600 mA (at 24V) current.
  • Page 82: Characteristics Of The Input Signal At The I / O Interface

    Figure 30: Behavior of the input voltage, examples flank rise: left - steep (desired), right - flat (not desired) Figure 31: Equivalent circuit diagram NANL-B500G-RE netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 83: Technical Data

    Time stamp resolution 10 ns Delay time network interface Delay TAP < 1 ns Signal dealy netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 84 (ø 5,5 / ø 2,1) L = 12 mm; Maximum permitted cable length: 3 m Power switch ON / OFF netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 85 To display the recorded analysis data of the Ethernet frames (supports WinPcap format) source Wireshark(recommended) Table 26: Technical data analyzer device NANL-B500G-RE netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 86: Annex

    As a consumer, you are legally obliged to dispose of all waste electronic equipment according to national and local regulations. netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 87 Behavior of the input voltage, examples flank rise: left - steep (desired), right - flat (not desired)....................82 Figure 31: Equivalent circuit diagram NANL-B500G-RE ............82 netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...
  • Page 88 Notes about installation and operation ..............Table 12: Overview installation....................Table 13: Overview how to update the installation ..............Table 14: Explanations to the front side and reverse side NANL-B500G-RE......Table 15: Workarround if firewall blocks communication............Table 16: netANALYZER configuration page ................. Table 17: Threshold for the temperature control of the fan ............
  • Page 89: Glossary

    IP address assignment essentially Ethernet Device Hilscher Software tool used eg for the netANALYZER device NANL- Configuration B500G-RE to configure the IP address and which is used for the modes "static IP address" or "DHCP Client"...
  • Page 90: Contacts

    E-mail: info@hilscher.us Support Support Phone: +39 02 25007068 Phone: +1 630-505-5301 E-mail: it.support@hilscher.com E-mail: us.support@hilscher.com netANALYZER device NANL-B500G-RE | Installation, operation and hardware description © Hilscher 2007-2019 DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public...

Table of Contents