808nm diode laser

Advertisement

Quick Links

808nm Diode Laser Operation
Manual
KES145
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KES145 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Body Life KES145 Series

  • Page 1 808nm Diode Laser Operation Manual KES145...
  • Page 2 V1.0 Beijing Kiers Science & Technology Co.,Ltd 1. Summary Thank you for using our 808nm diode laser hair removal equipment. 808nm diode laser hair removal machine is produced based on the development trend of laser hair removal market, adopts unique 808nm long pulse width laser wavelength, penetrate the skin to hair follicles, according to selective absorption principle, laser energy is absorbed by the black pigment, then make hair loss regeneration ability, during the treatment, the unique sapphire cooling system can effectively protect epidermis is not burned, to...
  • Page 3: Storage And Transportation Requirements

    temperature up to 40℃, heating the second pulse, so that the hair follicles and surrounding stem cells lose activity, the destruction of the hair follicles, so that the hair stop growth. There are two modes for option, Normal and Fast, make hair removal more safe, convenient and quick.
  • Page 4: Installation

    The hair removal equipment can only be placed in the original packaging box for transportation and storage, to avoid damage. Hair removal equipment should be stored existing ventilation, drying, temperature of 5 ℃ to 35 ℃ , environment relative humidity not more than 70%, avoid the acid, alkali and corrosive substance pollution, to avoid strong sunlight, transport to avoid severe large amplitude vibration, is strictly prohibited to rain or excessive isolation, is strictly prohibited throw.
  • Page 5: Electrical Protection

    radiation. Because most material of medical surgical equipments are glass, surface plating or nickel plated metal, the reflectivity is very high, the operation of laser, must not let the beam irradiation in the above, otherwise, the laser beam reflected on the human will body cause damage.
  • Page 6: Manual Recovery

    There is a limited current setting in the factory, forbidden the dangerous output.  Ensure the machine is connected to the ground wire during working.  The room which place the machine should be tidy and dry, ensure no liquid products put ...
  • Page 7 Pay special attention: Please carefully read the notice before use 5.Applications: Warning Only trained professional users can use this hair removal machine to do the treatment. Applications: Main treatment areas are: Beard, small arms, legs, armpits, forehead and other parts. Make sure the customer is suitable for use this machine before every treatment.
  • Page 8 equipments, otherwise, will cause personal injury and failure or error operation. ● Hearing aids, and other medical devices embedded in the human body. ● Electronic equipments for maintenance of life, such as breathing machine, external pacemaker. ● Electronic equipments for medical use in the body, such as the dynamic electrocardiogram.
  • Page 9: Power Switch

    6.3 Power switch There are three parts for the power supply, power switch, key switch and emergency switch. The machine can only work under the three buttons turned at the same time. There are two keys for one machine; the keys should be kept by professional users. 6.4 Laser output ATTENTION There is a sapphire crystal in the output window, forbidden to be blocked by any...
  • Page 10: Emergency Switch

    operating window, the parameters, mode and status of the machine can be adjusted from the button in the screen. It is very easy to learn and operation. 6.6 Emergency Switch Emergency switch connected with the general power supply, press the button, the machine will be turned off.
  • Page 11 Laser Power 600 W Energy 6~50 J/cm , adjustable Frequency 1~9 Hz, adjustable Pulse Width 30~100 ms, adjustable 8. Operation Manual WARNINGS The hair removal machine is carried out by the doctors who have received professional training and professional training of professional medical applications. The instruction manual is for the detail description of technology and use, excluding medical section.
  • Page 12 8.2 Add water Filling deionized cooling water: there is no deionized cooling water when use it at first time, so before open the machine, we should fill the deionized cooling water into the device. 1) Take out the water pipe, and then insert the butt joint into the water outlet of the bottom right of the back of the machine.
  • Page 13: System Start-Up

    8.3 System start-up Turn the switch key to “ON”, the fan works, LCD screen lights, and there will be the words “KIERS”. After opening the system, enter the boot interface. You can adjust below button to make the right value before do hair removal, after set, press “Ready” button. 8.3.1 Check the machine working-status and interface presentation After entering the work interface, then check if the status of the device is normal and check if there is warning.
  • Page 14: Operation

    disappears. Water temperature Warning: when the temperature of the water tank ② higher than 30℃. Make the machine standby mode, and then use the machine after the temperature alarm disappears. Sensor alarm: when the temperature of the water, hand piece and the ③...
  • Page 15 "prohibit" list. 4. Before using the equipment must be properly installed laser hand, specific methods are allowed. 1) before/after use, Laser hand must be cleaned by medical alcohol wipe, in case of cross infection. 2) The laser hand with a link plug must be firmly, tight, otherwise there may be a leak or not work 5.
  • Page 16 2)Fast Mode: Key Description: Notice:  1) When the operation must be kept hand piece and skin close contact, in order to achieve better results. 2) The energy output is controlled by two levels, that is, the "Ready" button is pressed, and then the energy output.
  • Page 17 8.5 Hair removal operation guidance 8.5.1 Arm hair removal: Step 1: cleaning Before hair removal, need to clean the area where the hair will be removed, the area for disinfection treatment. Step 2: shaving hair In order to carry out the hair removal, the laser can better conduction. The surface of the hair need to be shaved.
  • Page 18 Step 3: Smearing gel In order to maximize protection of the skin, in the process of hair removal is not suitable for the lowest, before hair removal, smear gel evenly to the area of hair removal. Step 4: Setting Parameters: The energy output, frequency output and laser output can be adjustable, to achieve the best user experience.
  • Page 19 Note: hair removal laser input energy from the mini value at the beginning then gradually increase to prevent the excessive damage to the skin caused by laser output. Step 5: Hair removal Hair removal techniques: the spot is closed to the skin using cross method, the intensity of uniform and then repeated sliding hair removal.
  • Page 20: Special Attention

    10. Special attention 1.The equipment power: AC220V, 50Hz; line capacity is not less than 1.5KW, and has a reliable grounding wire, before connecting power, please confirm the power parameters meet the requirements of the equipment, otherwise it may cause damage to the equipment and even lead to personal injury.
  • Page 21 3. Replace the filter element and de ionized water cooling water regularly. Note: 1 DI water cooling water must be replaced each week. 2 figure right for the ion exchange resin filter, ion exchange resin filter 1 months to replace. Remove the bottom Replace the ion resin filter equipment...
  • Page 22 12. Disclaimer 1. This equipment is a precision equipment, the operator is required to have some professional skills, in order to ensure safe use the machine, the operator must be trained; for all the consequences without professional training, blind operation has caused, our company is without any responsibility.