Service; Identification And Repair Of Faults; Fig.8 Replacing The Fluorescent Lamp - Igloo Jamajka W OPEN User Manual

Table of Contents

Advertisement

4

Fig.8 Replacing the fluorescent lamp

1 – Lamp grip
2 – Lamp
3 – Light housing
4 – Fluorescent igniter
During maintenance work, be careful not to damage the nameplate Fig.9 (p.13), which contains
important information for maintenance workers and waste disposal companies.

6. SERVICE

6.1. Fault identification and repair
In case of any difficulties during actuation of the device or during its exploitation, please return to these chapters in this
manual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still
experience difficulties, the following hints will help you solve the problem:
The device is not working... – Make sure that:
The device is connected to the supply network
Voltage and frequency in the network are compliant with those recommended by the producer, 230V/50Hz
The main switch is turned on
Thermostat is turned on (This concerns the Igloo thermostat – If only two spots are visible on the display – turn on
the thermostat)
The device is operating, but the lighting is off...– Make sure that:
Lighting switch is turned on
Fluorescent lamp or starting switch of the device is not burnt
The device does not reach the proper temperature, the lighting is on...– Make sure that:
The main switch is on
Temperature setting on the thermostat is properly set
Thermostat works properly
The condenser is clean, if necessary – clean the condenser
Ambient temperature does not exceed 25ºC
Enough time has passed for products to be cooled
Ventilation holes of the device are not blocked
(This concerns the "IGLOO" thermostat) thermostat displays C0 or C1 or C2 instead of displaying temperature:
This situation shall occur, when one of temperature regulation sensors has been destroyed. The following
messages may be displayed in such case:
C0 – temperature sensors inside the chamber are damaged – call authorized service
C1 – failure of evaporator sensor - call authorized service
C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service