Instructions For The Electrician; Test The Insulation Resistance/Ohm Values; Connection Diagram - Karibu 59319 Assembly And Operating Instructions Manual

Sauna heater
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
2 x Wall bracket
4 x Securing
screws (wood
screws) 5 x 35
Screws 4 x
M5 x 12
Bottom panel
Terminal box
Sauna
heater foot
Self-tapping
screws 3.9 x 9.5
Screws M5 x 12
4x
Note:

Instructions for the electrician

DIN VDE 0100 and Accident Prevention Regulation BGV A2 must be observed
for connecting the stove and all electrical systems. An external all-pole
disconnecting device with full isolation according to overvoltage category III
must be installed.
Important:
Mains connection leads must be flexible cables with polychlorophene sheaths.
No connection leads are supplied with the stove. All the cables installed inside
the cabin must be suitable for an ambient temperature of at least 140°C. Heat-
resistant silicon cables must be used. The minimum cross-section of the
connection cable and the minimum size of the sauna cabin are shown in the
table (Table 1 page 8). Make the electrical connection as shown in the
connection diagram . A connection diagram is additionally affixed to the inside
of the duct cover.
Fit the cover after making the electrical connection.
Please note that live cables must not be routed visibly on the internal walls of
the cabin for safety reasons. In prefabricated sauna cabins the wall element
with the air supply opening generally has empty cable conduits or a duct for
routing the cable.
If your cabin does not have any cable routing preparations, we recommend that
you install a connection socket (not supplied) to the outside of the cabin. Drill a
hole in the cabin wall near the cable infeed from the stove and the connection
socket. Thread the cable through the hole to the external connection socket. All
cables must be protected from damage. This can be achieved using installation
ducting/piping or using wooden covers.

Connection diagram

9 kW Saunaofen externe Steuerung
Test the insulation resistance
The resistance values between the various conductor terminals and the case
(protective earth) can be measured using an insulation resistance measuring
unit. The total insulation resistance between the conductor terminals and case
(protective earth) must definitely be greater than 1 MOhm.
Ohm values of the stoves
33 – 39 Ω for 9 kW sauna heater
GB
7

Advertisement

Table of Contents
loading

Table of Contents