Basic Operation; Hardware Design - Ebyte E73-2GM08S1C User Manual

Nrf52840 2.4 ghz smd
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.

5 Basic operation

5.1 Hardware design

It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible and
the module needs to be reliably grounded.
Please pay attention to the correct connection of the positive and negative poles of the power supply, reverse
connection may cause permanent damage to the module.
Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum,
the module will be permanently damaged;
Please check the stability of the power supply. Voltage can not fluctuate greatly and frequently;
When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, so the whole machine is beneficial for long-term stable operation;
The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference;
Bottom Layer High-frequency digital routing, high-frequency analog routing, and power routing must be avoided
under the module. If it is necessary to pass through the module, assume that the module is soldered to the Top Layer,
and the copper is spread on the Top Layer of the module contact part(well grounded), it must be close to the digital
part of the module and routed in the Bottom Layer;
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd
E73-2G4M08S1C User Manual
8

Advertisement

Table of Contents
loading

Table of Contents