Advertisement

Quick Links

ITS-950 ParQSense Base station
Installation Manual
Document number
Filename
Revision number
Date
Edited by
Checked by
Approved by
Rev.
01 – 01.02.2018
02 – 20.06.2018
03 – 11.07.2018
Q-Free ASA – Service Line Parking – P.O.Box 3974 Leangen – NO-7443 Trondheim – Norway
www.q-free.com – info@q-free.com
www.q-free.com – info@q-free.com
2018-820-002-ITS-950I
Installation Manual ITS-950 ParQSense Base Station
3.0
2018 July 11
BB
Description
First release version
Revised with FCC declarations
Revised with ISED declarations

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITS-950 ParQSense and is the answer not in the manual?

Questions and answers

Summary of Contents for Q-FREE ITS-950 ParQSense

  • Page 1 01 – 01.02.2018 First release version 02 – 20.06.2018 Revised with FCC declarations 03 – 11.07.2018 Revised with ISED declarations Q-Free ASA – Service Line Parking – P.O.Box 3974 Leangen – NO-7443 Trondheim – Norway www.q-free.com – info@q-free.com www.q-free.com – info@q-free.com...
  • Page 2: Table Of Contents

    Modular devices .......................... 10 ISED DECLARATIONS ........................11 Interference Statement (RSS-GEN, Section 8.4): ............... 11 Modular devices .......................... 11 Antenna information to user (RSS-Gen Issue 5 section 6.8) ............11 RF exposure statement, for outdoor Mobile device) ..............12 www.q-free.com – info@q-free.com...
  • Page 3: Introduction

    1 INTRODUCTION 1.1 Scope and purpose The scope of this document is to provide specifications for the installation and deployment of Q-Free ITS- 950 ParQSense Base Station. For clarification, the following is outside the scope of this document: Installation of the ITS-420 ParQSense Standard Outdoor Sensors...
  • Page 4: Listing Of Figures

    1.4 Listing of Figures Figure 1 ITS-950 Base Station ........................5 Figure 2 Communication overview ITS-420 ParQSense Sensors ..............6 Figure 3 Pole Mount Kit ..........................8 Q-Free ITS-950 ParQSense Base station Installation Manual Page 4 of 12...
  • Page 5: Preparation Of The Installation

    Typical applications are on/off-street monitoring for public, private lots/spaces, Smart City Initiatives, etc. The Q-Free ITS-950 ParQSense Base Station is of slimline design to be installed onto lighting poles, building roof-tops/sides, etc. The installation process is easy and expected to take about 30 minutes for each ITS-950 ParQSense Base Station.
  • Page 6: System Communication

    3.3 Mounting location The ITS-950 ParQSense Base Station can be pole mounted or wall mounted. Prior to going on site to install the ITS-950 ParQSense Base Station it should be determined where the base station should be installed based on a site survey and direction by a Q-Free representative.
  • Page 7: Back End System Communication

    Connecting the POE cable for power and communication. 3.4 Back end system communication The ITS-950 ParQSense Base Station will connect to the provided hard wired network connection. The following should be complete prior to installing the Base station on site: ...
  • Page 8: Installation Of The Equipment

    The following section describes the installation steps for installing the ITS-950 ParQSense Base Station. Pole Mount The ITS-950 ParQSense Base Station will be provided with a pole mount kit. This can be used for mounting the ITS-950 ParQSense Base Station to the proposed pole location.
  • Page 9: Status Lights

    5. Attach back plate using hardware to installed anchors. 6. Reattach ITS-950 ParQSense Base Station to back plate. 7. Plug in the outdoor rated Cat5 cables using an outdoor rated connected to the ITS-950 ParQSense Base Station 8. Check for connectivity and activity on the Status Lights on the bottom of the unit near the Cat5 connection.
  • Page 10: Installation Validation

    For testing of the ITS-420 ParQSense Standard Outdoor Sensors communication to the ITS-950 ParQSense Base Station, refer to the ITS-420/421 ParQSense Outdoor Sensor Installation Manual. Any necessary adjustments to the default settings of the ITS-950 ParQSense Base Station can be made in the ParQSense backend software system.
  • Page 11: Ised Declarations

    This device and it's antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except inaccordance with IC multi-transmitter product procedures. Cet appareil et son antenne (s) ne doit pas être co-localisésou fonctionnement en association avec une autre antenne outransmetteur. Q-Free ITS-950 ParQSense Base station Installation Manual Page 11 of 12...
  • Page 12: Rf Exposure Statement, For Outdoor Mobile Device)

    Cet équipement est conforme aux limites d’exposition auxrayonnements IC établies pour un environnement non contrôlé.Cet équipement doit être installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps. Q-Free ITS-950 ParQSense Base station Installation Manual Page 12 of 12...