Vetter V10 Technical Data Manual

Vetter V10 Technical Data Manual

Mini-lifting bags 8 bar (116 psi) / super mini-lifting bags 8 bar (116 psi)

Advertisement

Vetter Mini-Lifting Bags 8 bar (116 psi)
Vetter Super Mini-Lifting Bags 8 bar (116 psi)
Contents
Introduction .................................. 18
Safety instructions ........................ 18
height ........................................... 20
Vetter System ............................... 20
Air supply ..................................... 21
cylinders 200 or 300 bar ................ 21
deadman control ........................... 22
construction .................................. 22
(116 psi) ....................................... 23
8 bar (116 psi) .............................. 23
sources ........................................ 24
Practical tips ................................. 25
Troubleshooting ............................ 27
Recurrent tests ............................. 27
Table of recurrent tests .................. 28
89/392/EEC ................................. 32
18

Introduction

Lifting bags may only be
operated with compressed-
air - or with water in excep-
tional cases -(accessories
on request), though never
with flammable or aggres-
sive gases. The lifting bags
may only be operated using
original Vetter fittings.
Mini-Lifting Bags (steel or
Aramide) of types V24 -
V31 - V40 - V54 - V68
(VS26 - VS34 - VS43 -
VS59 - VS74) fall under the
Pressure Vessel Legislation
from July 1st, 1980, in
Germany (DruckbehV).
These lifting bags may only
be put into operation after
submission of the manufac-
turer's certificate of official
acceptance. This test
certificate should be kept in
a safe place and presented
to the test expert at the
repeat test.
Pay attention to DIN 7716 if
stored for longer periods of
time. We will be happy to
supply an excerpt from this
standard.

Safety instructions

Use only Vetter original
fittings. Only these have
been tested in the
works in accordance
with the Pressure
Vessel Legislation.
Please check the
perfect and correct
condition of the lifting
bags and accessories
before and after every
use.
Insert bags at suitable
points so that at least
75% of the bag's
surface is beneath the
load.
Avoid angles larger than
30 degrees (relationship
between base and load
to be lifted). The bag
could be catapulted out
of the gap. Create a
parallel base to the load
to be lifted whenever
possible using a sturdy
substructure.
Never place more than
two bags on top of one
another.

Advertisement

Table of Contents
loading

Summary of Contents for Vetter V10

  • Page 1: Table Of Contents

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Contents Introduction Safety instructions Introduction ........18 Lifting bags may only be • Use only Vetter original Safety instructions ......18 operated with compressed- fittings. Only these have Behaviour of the lifting power ..
  • Page 2: Behaviour Of The Lifting Power

    - 20°C (- 4°F) The Vetter Mini-Lifting Bags (max. - 40°C (- 40°F)) • If a substructure is used 8 bar (116 psi) operate and temporarily up to...
  • Page 3: Increasing The Lifting Power And Lifting Height

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) The lifting power - load path Increasing the lifting bags cannot be inflated diagram (cf. P . 31) facilitates power and lifting with an excess operating...
  • Page 4: Air Supply

    Air reserve (l) = pressure If the pressure is greater (bar) x cylinder volume (l) than 10 bar (146 psi) the Vetter pressure reducer (Art.-No. 160 21 000) has Set the back pressure to to be used. approx. 10 bar (146 psi) with the adjusting screw (4) (display on manometer (2)).
  • Page 5: Operating With The Dual Controller And Deadman Control

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Operating with the exceeds 8 bar (116 psi) the dual controller and safety valve opens. deadman control Push the lever forwards to lower the load or com- pletely deflate the Mini- Lifting Bags.
  • Page 6: Safety Against Exceeding The Maximum Working Pressure Of 8 Bar

    Close the air supply. Open Operating Once the desired lifting the ball valve briefly to Super Mini-Lifting height or maximum depressurise the pressure Bags 8 bar (116 psi) working pressure of 8 bar reducer’s air hose or air (116 psi) is reached, close Version with supply hose from the the cylinder valve by turning...
  • Page 7: Operation With Other Compressed-Air Sources

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Version with foot pump Operation with other compressed-air The foot pump included sources with the bags is fitted with a Vetter adaptor sets are safety valve and mano-...
  • Page 8: Practical Tips

    Insert prop under axle bag then the lower bag. Vetter Mini Lifting Bag 8 after raising, though Never deflate the bar (116 psi) and Super never work under a...
  • Page 9: Maintenance And Servicing

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Warning Maintenance and use. They cannot be servicing repaired for safety reasons. Risk of injuries from broken metal Damages to the bag’s Check that the Mini-Lifting parts and stones.
  • Page 10: Troubleshooting

    Troubleshooting Recurrent tests Vetter Mini-Lifting Bags See following pages for have no moving parts tables. which can wear or have to The operator is responsible be serviced. for the correct performance Despite the greatest of care of the recurrent tests in...
  • Page 11: Table Of Recurrent Tests

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Table of recurrent tests Time Type of test Tester Documentation Basis Interval Before initial Acceptance inspection Safety expert or DruckbehV § 9,5 commissioning Within the scope of...
  • Page 12: Technical Data With Steelcord Reinforcement (European Versions)

    Technical data with steelcord reinforcement (European versions) Type V24L Art.-No. 131 01 000 131 02 000 131 03 000 131 04 000 131 05 000 Lifting capacity max. 9,600 12,000 17,700 24,000 24,000 Lifting height, max. 20.3 20.0 27.0 30.6 20.1 Size 37 x 37...
  • Page 13: Technical Data With Aramide Reinforcement (European Versions)

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Technical data with aramide reinforcement (European versions) Type Art.-No. 139 01 000 139 02 000 139 03 000 139 41 000 131 42 000 Lifting capacity max.
  • Page 14: Lifting Power - Load Path Diagram

    Type V24L Art.-No. 131 43 000 131 44 000 131 45 000 131 46 000 Lifting height, max. 17,700 24,000 24,000 31,400 Lifting height, max. 27.0 30.6 20.1 37.0 Size 47 x 52 52 x 62 31 x 102 65 x 69 Insertion height Nominal content litre 21.7...
  • Page 15: Ec Declaration Of Conformity In The Intendment Of Ec Machine Directive 89/392/Eec

    Lifting Bags 8 bar / 116 psi (with aramide reinforcement) V1, V3, V6, V10, V12, V18, V24, V24L, V31, V40, V54, V68 Lifting Bags 8 bar / 116 psi (with steel cord reinforcement) V10, V12, V18, V24, V24L, V31, V40, V54, V68 to raise and lower loads Serial no.:...
  • Page 16: Technical Data With Steelcord Reinforcement (Us Versions)

    Technical data with steelcord reinforcement (US versions) Type VS10 VS13 VS19 VS26 VS26L Art.-No. 131 01 000 131 02 000 131 03 000 131 04 000 131 05 000 Lifting capacity max. tons 10.58 13.2 19.51 26.46 26.46 Lifting height, max. 10.6 Size 15 x 15...
  • Page 17: Technical Data With Aramide Reinforcement (Us Versions)

    Vetter Mini-Lifting Bags 8 bar (116 psi) Vetter Super Mini-Lifting Bags 8 bar (116 psi) Technical data with aramide reinforcement (US versions) Type VSK1 VSK3) VSK6 VSK10 VSK13 Art.-No. 139 01 000 139 02 000 139 03 000 131 41 000 131 42 000 Lifting capacity max.
  • Page 18 Type VSK19 VSK26 VSK26L VSK34 Art.-No. 131 43 000 131 44 000 131 45 000 131 46 000 Lifting height, max. tons 19.51 26.46 26.46 34.61 Lifting height, max. 10.6 11.9 14.6 Size 47 x 52 52 x 62 31 x 102 65 x 69 Insertion height Nominal content...

Table of Contents