A detailed parts list for INGENIA CAH equipment can be found in the "Installation, Operation and Maintenance Manual for Ingenia Indoor Units" under section 8.0 "Installation Procedure for Indoor Modular Units." This section includes hardware supplied by Ingenia, such as bolts, screws, gaskets, and other components.
11.1 Addition / Modification of components to ETL units in the field (ETL Disclaimer) 12.0 Replacement Parts Appendix A Stacked modules and Floor Opening Appendix B Pulling together wide modules on roof curb or structural steel Appendix C Fan IOM Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Report any damaged equipment to the transport company on the packing slip. All Ingenia air handling systems are shipped fully shrink wrapped to prevent damage during transport. The transporting carrier is responsible for delivering all items in their original condi- tion as received at Ingenia.
A. When installing an air handler, ensure the proper protective devices are used to protect per- sonnel from moving parts and other hazards. A complete line of protective accessories are available from Ingenia including: plenum enclosures, inlet screens, outlet screens, motor co- vers, belt guards and electrical disconnects.
E. REFER TO THE LIFTING LUGS DRAWINGS SUPPLIED. COVER THE UNIT Cover the Unit properly if it is not fully assembled by the end of the work day and exposed to the environmental conditions (wind and rain). Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Come Along , Straps (short and long) and Jacks Threaded Rods with Nuts and Washers The following hardware will be supplied by Ingenia for the installation of a modular outdoor unit. VIS FTSQ 1/4”-20X5/8 GASK 20100MAA VIS AP HH 12-3/4”...
Keeping the modules together (figure 8A) By reinstalling the lifting lugs on the side of the unit, use threaded rods (not provided by In genia) to keep the modules compressed against each other. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 11
STEP 6: Sealing the Module Interior seams (figure 10) Caulk the interior wall and roof seam with either gray or white Silaprene depending on the ap plication and interior colour. The caulking will be supplied by Ingenia. STEP 7: Installation of the Roof top Cladding Each modular roof top joint requires a roof cladding segment to be field installed after com pleting steps 1 through 6.
Ingenia Panels Ingenia offers both fiberglass type insulated panels as well as foam injected panels. The foam panel offers a better thermal resistance, provides a stronger more rigid panel and elim- inates any moisture penetration inside the insulation.
Door Adjustment ACCESS DOOR WINDOWS Access door windows (Viewport) are safe for viewing UV-C germicidal lamps at 254nm wavelength. UV Transmittance report is readily available upon request. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Proper tightening is required. HEPA FILTER BRACKETS Use the provide filter brackets referred to as swing bolts. There are four (4) filter swing bolts per filter. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
No perforations are to be made through the HEPA Filter Frames and/or blanks for electrical or control conduits. Connections will have to be made from the outside of the unit or through a vestibule (if applicable). Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Fig. Angle Motor Hoisting from Monorail If the initial lift angle is more than 10 deg, the motor will have to be moved closer to the monorail before being lifted. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Therefore, it is important that the concrete be perfectly level and filled to the top of the c-channel. If this is not done, the fan and motor assembly center of gravity will be shifted and the isolators selected, will no longer be valid. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 29
PLEASE REFER TO THE IOM OF THE FAN AND MOTOR MANFACTURER FOR LUBRICATION SCHEDULES. THEY MAY DIFFER FROM EACH OTHER. Appendix C shows the IOM for the most used fans. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 33
An air leak can usually be detected by sound or feel and should be noted on the start-up check-list and also mentioned to the installing contractor. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 34
START-UP INFORMATION General Notes: 1. Send a copy of the start-up check-list to Ingenia when completed. All information should be filled in to facilitate an internal review by Ingenia. 2. If at start-up there are any deficiencies or abnormalities, please indicate it on the start-up sheet.
Page 35
Heat Recovery Wheel Seals to be properly adjusted (if applicable) (refer to wheel manufacturer IOM) Heat Recovery Wheel Rotation and Run-out to be verified (if applicable) (refer to wheel manufacturer IOM) Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 36
Fan Total Static Pressure (“ W.G.) Fan External Static Pressure (“ W.G.) Fan RPM Brake HP Return Fan Motor Data Phase 1 Phase 2 Phase 3 Oper. Amps Oper. Volts Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 37
Indicate below any deficiencies or abnormalities noticed when performing the start-up. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
It is important to clean inside the fins to remove any potential mould build-up especially in cooling coils. The benefits of cleaning the coils will also be seen in the energy savings due to reduced air pressure drop and also increased coil efficiency. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Please note that items coated with Antimicrobial powder coatings must be kept clean in order to maintain antimicrobial behavior. Regular house keeping is required to prevent dust, dirt and other potential barriers from accumulating. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
YEAR from start-up or EIGHTEEN (18) MONTHS from shipment, whichever comes first. Ingenia will, at its option, repair or replace the product, or any part thereof, found in its opinion to be defective, provided the defective part or product is returned to Ingenia. Notwithstanding the preceding, the present war-...
ETL Certification of the unit if the component(s) are not ETL, UL or CSA listed and if the connections/wiring are not to the UL standards. Thus Ingenia will not be liable, in any manner, should any non-listed or certified components are added to the Ingenia ETL listed units.
APPENDIX B PULLING TOGETHER WIDE MODULES ON ROOF CURB OR STRUCTURAL STEEL (IF NECESSARY) Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Page 45
(come-along) and the jack. Anchoring of the jack will depend on site conditions and should be done with proper support. This method is to be used if absolutely necessary and with care. Installation, Operation and Maintenance Manual for Ingenia Outdoor Units CAH-OD-16-00...
Need help?
Do you have a question about the CAH and is the answer not in the manual?
Questions and answers
Where can I get a detailed parts list of this equipment?
A detailed parts list for INGENIA CAH equipment can be found in the "Installation, Operation and Maintenance Manual for Ingenia Indoor Units" under section 8.0 "Installation Procedure for Indoor Modular Units." This section includes hardware supplied by Ingenia, such as bolts, screws, gaskets, and other components.
This answer is automatically generated
how often do you change the filters