5
Simulation mode
Changeover to simulations mode Press «Sim1»
Changeover to simulation mode:
Press the Sim1 + Sim2 buttons
simultaneously for 2 seconds.
Simulation mode:
Activation of the loop
Activation of the output relay
Alarm output activation
Inductance of loop 1
Inductance of loop 2
Exiting simulation mode
6
Troubleshooting
If an error occurs, operating mode «A» and error display «E» light up alternately and an error code such as E 012 is displayed. The LED changes to
flashing red, the 4 most recent errors are stored and can be interrogated.
Display
E001
Interruption
Error
Loop 1
Briefly pressing the «Data» button shows the last of 4 errors on the display. Another short press switches to the error before that, and so on. When
the button is pressed for the 5th time, the device switches back to automatic mode. If you press the «Data» button for 4 seconds during the query,
all error messages are deleted. The figure shows memory slot 1 in which error 001, Interruption loop 1, has been stored (example).
7
Reset
Reset 1 (recalibration)
Mode
Sim1
The loop(s) is/are recalibrated.
2 Sekunden
Most important technical data
8
Supply voltage /
Current consumption /
Power consumption
Loop inductance
Loop connection wiring
Loop resistance
Output relay (loop)
Dimensions
Housing mounting
Connection type
Protection class
Approvals, safety
Operating temperature
Storage temperature
Air humidity
9
Declaration of conformity
Manufacturer: Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen declares that the
product, Typ: ProLoop2 11-pin
Model: ProLoop2 1.S.xxxxxx, ProLoop2 2.S.xxxxxx, ProLoop2 1.S.78.xxxxxx, ProLoop2 2.S.78.xxxxxx, 24ACDC, 115AC, 230AC
Intended purpose: Programmable loop detector for controlling gates and barriers as well as for regulating and counting cars in parking areas
if used in accordance with the intended purpose, complies with the basic requirements acc. to:
R&TTE Directive, Appendix III 1999/5/EC
Contact data
10
Manufacturer:
Bircher Reglomat AG
Wiesengasse 20
CH-8222 Beringen
Switzerland
4
Press «Sim2»
button
button
Data
Mode
Sim2
Sim1
2 seconds
2 seconds
Data
1
Sim2
Mode
Data
1
Sim1
Sim2
Mode
Data
Sim1
Sim2
Mode
1
Sim1
Mode
2
Sim1
Mode
1
2
Sim1
2 seconds
E002
E011
E012
Interruption
Short circuit
Short circuit
Loop 2
Loop 1
Loop 2
ProLoop2 11-pin
24 VAC –20% to +10%, 84 mA, max. 1.8 VA
24 VDC –10% to +20%, 84 mA, max. 1.3 W
115 VAC –15% to +10%, 30 mA, max. 3.5 VA
230 VAC –15% to +10%, 16 mA, max. 3.7 VA
max. 20 to 1000 µH,
ideally 80 to 300 µH
At 20-40 µH: max. 100 m at 1.5 mm
At >40 µH: max. 200 m with 1.5 mm
min. twisted 20x/m
< 8 Ohm with connection wire
AC-1: max. 240 VAC; 2 A / DC-1: max. 30 VDC; 1 A
36 x 74 x 88 mm (W x H x D)
Mounting rail installation via 11-pin base ES 12
Screw terminals base ES 12
IP 20
See declaration of conformity at www.bircher-reglomat.com
–20°C to +60°C
–40°C to +70°C
<95% non-condensing
www.bircher-reglomat.com
info@bircher.com
Phone +41 (0)52 687 1111
Fax
+41 (0)52 687 1112
Press «Sim2»
Press «Sim2»
button
button
1
Mode
1
2
Sim1
1
Mode
2
Sim1
E101
E102
E201/E202 E301
Under -
Over-
Saving
voltage
voltage
error
Mode
Data
Sim1
Sim2
8 Sekunden
2
2
Danish seller: Swissdoor ApS
Stenhuggervej 2
DK-5471 Soendersoe
Danmark
Anmerkungen
L0 -
L1 -
No loop activation (time functions are active)
Data
2
Loop activation (time functions are active)
Sim2
- Loop 1
- Loop 2
0 -
0
1 -
Activation of output
Data
0
2
Sim2
Activation of output
- Loop 1
- Loop 2
A0
A1
-Switch off alarm relay
Switch on alarm relay
-
Measurement of the inductance, value in
Measurement of the inductance, value in
Return to function mode
E302
E311
Loop 1
Loop 2
Loop 1
too large
too large
too small
Reset 2 (factory setting)
All values (except the error memory) are reset to the factory
settings (see Table 4.11a). The loop(s) is/are recalibrated.
Tel.: +45 86 28 00 00
mail@swissdoor.dk
www.swissdoor.dk
µH
µH
E312
Loop 2
too small

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProLoop2 and is the answer not in the manual?

Questions and answers