Download Print this page

Bircher Reglomat ProLoop2 Manual

Loop detector for industrial doors and gates, car parks and parking bollards

Advertisement

Quick Links

ProLoop2
Translation of the original instructions
General
1
Safety instructions
These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended supply voltage and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
Mechanical mounting in the switch cabinet
2
The 11-pin version of the ProLoop is mounted onto a mounting rail base (ES 12). This base is ordered and delivered separately as it is not included in the
scope of delivery.
3
Electrical connection
The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please wire the device in accordance with the terminal assignment. Make sure the terminals are assigned correctly.
Terminal connection diagram, ES 12 base assignment
Check the electrical connection (base assignment) when exchanging a loop detector from another manufacturer.
A:
B:
Supply
Loop connection
voltage
1-channel device
connection
34
AC
A1
24
1
AC
11
32
1)
Only applies to ProLoop2 with the designation «... .S.78. ... .»
4
Value and parameter setting options
General
The settings of the ProLoop devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be
made using the corresponding method.
LCD display and controls
4.1
Standard display
Standard display
1-loop device
2-loop device
1
1
2
(11-pin)
LCD display
«Mode»-button
«Data»-button
Plug-in connection, 11-pin
Info LED
1)
C2
:
C1:
Loop connection
Loop connection
2-channel device
2-channel device
34
34
2
2
24
32
1
1
32
24
Control button
Control button
Mode
Data
Sim1
Sim2
Loop detector for industrial doors and gates,
car parks and parking bollards
D:
E:
Relay connection
Relay connection
output 1
output 2
common
common
21
12
nc
nc
A2
31
22
14
no
no
Explanation of the LCD display
Loop 1
Function
Loop 2
1
2
Example:
Time
Example:
function set
Parameter
«h» set
Explanation of the LED
Red & green: Start-up phase
Green:
Operation
Red & green: Configuration
Info
Flashing green: Loop activated
Flashing red:
Error
Flashing
red + green:
Simulation
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProLoop2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bircher Reglomat ProLoop2

  • Page 1 Only applies to ProLoop2 with the designation «..S.78..» Value and parameter setting options General The settings of the ProLoop devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be made using the corresponding method.
  • Page 2 Basic functions 0 (see Table 4.11a for settings) Parameters 1: Door and gate The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition. 2: Barrier The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition. 3: Quiescent current The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
  • Page 4 Manufacturer: Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen declares that the product, Typ: ProLoop2 11-pin Model: ProLoop2 1.S.xxxxxx, ProLoop2 2.S.xxxxxx, ProLoop2 1.S.78.xxxxxx, ProLoop2 2.S.78.xxxxxx, 24ACDC, 115AC, 230AC Intended purpose: Programmable loop detector for controlling gates and barriers as well as for regulating and counting cars in parking areas if used in accordance with the intended purpose, complies with the basic requirements acc.