Advertisement

Quick Links

USER MANUAL
11UNO
Power Monitor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11UNO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Standa 11UNO

  • Page 1 USER MANUAL 11UNO Power Monitor...
  • Page 2 (from date of shipment) against material and/or workmanship defects, when used under normal operating conditions. The warranty does not cover damages related to battery leakage or misuse. Standa will repair or replace, optionally, any 11UNO that proves to be defective during the warranty period, except in the case of product misuse.
  • Page 3 Revision 6 SAFETY INFORMATION Do not use the 11UNO if the device or the detector looks damaged, or if you suspect that the 11UNO is not operating properly. Appropriate installation must be done for water-cooled and fan-cooled detectors. Refer to the specific instructions for more information.
  • Page 4: Table Of Contents

    ECYCLING AND SEPARATION PROCEDURE ..............................12 EPARATION ........................... 12 ISMANTLING PROCEDURE LIST OF ILLUSTRATIONS . 1-1 11UNO F ........................6 RONT ANEL . 1-2 11UNO C ........................7 ONNECTORS . 1-3 11UNO LCD D ........................9 ISPLAY Standa Ltd. All rights reserved...
  • Page 5: Introduction

    THE 11UNO SINGLE CHANNEL LASER POWER METER 1.1 Introduction To obtain full performance from the 11UNO, we recommend that you read this manual carefully. The 11UNO is a large display laser power monitor that features outstanding efficiency, ease of use and battery life. Unpacking Each Standa 11UNO is thoroughly tested and calibrated prior to shipment.
  • Page 6: Specifications

    The following specifications are based on a one-year calibration cycle, an operating temperature of 18 to 28ºC (64 to 82ºF) and a relative humidity not exceeding 80%. Table 1-1 List of Specifications 11UNO POWER METER SPECIFICATIONS 10 nW to 10 kW Power Range...
  • Page 7: Front Panel Description

    9). The hidden dBm function is available by pressing more than 2 seconds on the Zero control key.The 11UNO will convert the displayed number in dBm (dB referenced to 1mW) and will display “dBm” unit. To get back to the previous display in Watt, press again more than 2 seconds on the Zero control key.
  • Page 8: Connector Description

    This section contains important information concerning the installation and operation of the 11UNO. The 11UNO is delivered ready to use. Just install the 4 AA batteries, insert a detector head in the Probe Input Jack (#2 in Figure 1-2) and press the I/O key.
  • Page 9 Block off laser radiation to the detector. The power read by the 11UNO when no laser beam is incident on the detector may not be exactly zero. This is because the detector is not thermally stabilized OR there was a heat source in the detector’s field of view when you turned on the 11UNO, OR from the internal...
  • Page 10: Display Description

    The LCD provides measurement information, wavelength information, attenuator selection and other useful messages. When the batteries are discharged enough to compromise the measurement, the 11UNO displays “LO” instead of the measurement. Refer to the battery maintenance section to replace the batteries.
  • Page 11: Battery Selection

    11UNO. Good quality rechargeable batteries can also be used with the 11UNO and recharged with an external charger. The batteries need to be replaced if the 11UNO displays “LO” on its digital display or if it does not power- up when the I/O control key is pressed.
  • Page 12: Declaration Of Conformity

    Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for EN 61000-3-2:2006 Class A harmonic current emissions (equipment input current <= 16 A per +A1:2009 phase) We hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Standa Ltd. All rights reserved...
  • Page 13: Recycling And Separation Procedure

    3.4 Recycling and separation procedure This section is used by the recycling center when the monitor reaches its end of life. Breaking the calibration seal or opening the monitor will void the 11UNO warranty. The complete Monitor contains 1 Monitor...

Table of Contents