DAVIS EnviroMonitor 6810 User Manual page 14

Ethernet gateway and node
Hide thumbs Also See for EnviroMonitor 6810:
Table of Contents

Advertisement

1. Install the sensor in the environment per the
manufacturer's instructions, making sure the
sensor is installed within cable reach of the Node
when it is mounted.
2. On your smartphone, open the EnviroMonitor
app and select this Node. Tap Add Sensor. From
the menu, first select the sensor type, then the
specific sensor. Follow the wiring diagram in the
app to correctly wire the sensor into one of the
green 6-wire sensor connectors. Using a 2.5mm
(3/32") precision slotted screwdriver, loosen the
appropriate screws and insert the bare wires.
3. Tighten the screws very tight.
4. Insert the 6-wire sensor connector into the sensor port indicated by the app.
Make sure it is aligned properly and not offset.
Note:
If the Davis sensor has an RJ-plug on its
cable, use the Davis RJ Adapter, product
number 6860. Or, you can remove the
plug and strip the wires.
Try not to strip the covering back so far
that the bare wires can touch each other
when the connector is plugged in, but make sure the clamp in the sensor port is
closing on wire, not plastic. (About 1/4" [6.4 mm] of exposed wire is ideal.)
5. Run the sensor cable down and
out of the box through the
bottom. Make sure it will be
enclosed by the foam when
the Node door is closed.
6. When all sensors are installed,
close the Node door, making
sure all cables are against the
foam and not the hard plastic
of the door. Use included zip
ties and adhesive mounts if
desired.
12
Wire each
sensor as
directed in
the App
RJ Adapter,
#6860
Adhesive
Mount
Make sure
cables exit
against
the foam.
Note: Make sure none of the
sensor cables are pinched in
the door; especially the cable
on the the sensor installed in
Port 1.
Foam

Advertisement