PART 1 - REGULATIONS AND ASSEMBLY
Instructions in English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRESIA 70 AIR 9 S1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Red Heating FRESIA 70 AIR 9 S1

  • Page 1 INSTALLATION AND USER MANUAL INSERT FRESIA 70 AIR 9 S1 PART 1 - REGULATIONS AND ASSEMBLY Instructions in English...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS ....................II INTRODUCTION ......................1 1-WARNINGS AND WARRANTY CONDITIONS ..............2 2-INSTALLATION ......................8 3-DRAWINGS AND TECHNICAL SPECIFICATIONS ............17 4-UNPACKING ......................19 5-OVERALL DIMENSIONS ...................20 6-PRELIMINARY OPERATIONS ..................23 7-TYPE OF FASTENING ....................26 8-ACCESSORIES ......................33 9-ASSEMBLING THE ACCESSORIES ................35 10-INSERT EXTRACTION AND LOADING PELLETS IN COLD MACHINE ......36 11-DOOR OPENING ....................38 12-ELECTRICAL CONNECTION ..................39...
  • Page 3: Introduction

    INTRODUCTION Dear Customer, our products are designed and manufactured in compliance with European reference standards for construction products (EN13240 for wood-burning stoves, EN14785 for pellet-burning appliances, EN13229 for fireplaces/wood-burning inserts and EN 12815 for wood- burning range cookers), with high quality materials and extensive experience in transformation processes. The products also meet the essential requirements of Directive 2006/95/EC (Low Voltage) and Directive 2004/108/EC (Electromagnetic Compatibility).
  • Page 4: 1-Warnings And Warranty Conditions

    1-WARNINGS AND WARRANTY CONDITIONS SAFETY WARNINGS • Installation, electrical connection, operating check and maintenance must only be carried out by authorised and qualified personnel. • Install the product in accordance with all local and national legislation and regulations in force in the region or state. • Only use the fuel recommended by the manufacturer.
  • Page 5 1-WARNINGS AND WARRANTY CONDITIONS • Do not dry linen on the product. Any drying racks or the like must be kept at a safe distance from the product. Fire hazard. • All liability for improper use of the product is entirely borne by the user and relieves the manufacturer of any civil and criminal liability.
  • Page 6 1-WARNINGS AND WARRANTY CONDITIONS • The product and the cladding must be stored in a dry place and must not be exposed to weathering. • It is recommended not to remove the feet that support the product in order to ensure adequate insulation, especially if the flooring is made of flammable materials.
  • Page 7 1-WARNINGS AND WARRANTY CONDITIONS INFORMATION: Please contact the retailer or qualified personnel authorised by the company to resolve a problem. • Only use the fuel specified by the manufacturer. • When the product is switched on for the first time, it is normal for it to emit smoke due to the paint heating for the first time. Therefore make sure the room in which it is installed is well ventilated.
  • Page 8 1-WARNINGS AND WARRANTY CONDITIONS Installations that do not meet the current standards, improper use and lack of maintenance as expected by the manufacturer, void the product warranty. The warranty is valid on the condition that the instructions and warnings contained in the user and maintenance manual are observed, and therefore the product is used correctly.
  • Page 9 1-WARNINGS AND WARRANTY CONDITIONS SPARE PARTS In the event of a malfunction, consult the retailer who shall forward the call to the technical support centre. Only use original spare parts. The retailer or support centre can provide all necessary information regarding spare parts. We do not recommend waiting for the parts to get worn out before having them replaced.
  • Page 10: 2-Installation

    2-INSTALLATION The instructions in this chapter refer explicitly to the Italian installation regulation UNI 10683. In any case, always observe the regulations in force in the country of installation. PELLETS Wood pellets are manufactured by extruding sawdust which is produced during the processing of natural dried wood (without paint). The compactness of the material is guaranteed by the lignin contained in the wood itself and allows the pellets to be produced without glue or binders.
  • Page 11 Flammable walls A = mm A = 100 + 30 (INSULATION) mm FRESIA 70 AIR 9 S1 B = mm B = 50 + 30 (INSULATION) mm If the floor is made of combustible material, it is recommended to use a protection made of non-combustible material (steel, glass...) that also protects the front from any falling combusted material during cleaning operations.
  • Page 12 2-INSTALLATION FOREWORD The Flue chapter has been drawn up with reference to the provisions of European Standards (EN13384 - EN1443 - EN1856 - EN1457). The chapter provides indications for installing an efficient and correct flue but is under no circumstances to substitute the regulations in force, which the qualified manufacturer must be in possession of.
  • Page 13 2-INSTALLATION TECHNICAL SPECIFICATIONS Have the efficiency of the flue checked by an authorised technician. The flue must be sealed against flue gasses, in a vertical direction without narrowing, be made with materials impermeable to smoke, condensation, thermally insulated and suitable to resist normal mechanical stress over time (we recommend fireplaces made of A/316 or refractory material with insulated round section double chamber).
  • Page 14 2-INSTALLATION ROOF AT 60° ROOF AT 45° 45° 60° A = MIN. 2.60 metres A = MIN. 2.00 metres FIGURE 5 FIGURE 6 B = DISTANCE > 1.20 metres B = DISTANCE > 1.30 metres C = DISTANCE < 1.20 metres C = DISTANCE <...
  • Page 15 2-INSTALLATION MAINTENANCE The flue must be kept clean, since the deposit of soot or unburnt oils reduces the cross-section, blocking the draught and thus compromising the efficient operation of the stove and, if large build-ups accumulate, can catch fire. The flue and chimney pot must be cleaned and checked by a qualified chimney sweep at least once a year.
  • Page 16 2-INSTALLATION EXTERNAL AIR INLET It is mandatory to provide an adequate external air inlet that supplies the combustion air required for the product to work properly. The flow of air between the outside and the installation room may be direct, through an inlet in an external wall of the room (preferable solution see Figure 9 a), or indirect, via air intake from adjoining rooms and connecting permanently with the installation room (see Figure 9 b).
  • Page 17 2-INSTALLATION DISTANCE (metres) The air inlet must be at a distance of: 1.5 m BELOW Doors, windows, smoke outlets, cavities, ..1.5 m HORIZONTALLY Doors, windows, smoke outlets, cavities, ..0.3 m ABOVE Doors, windows, smoke outlets, cavities, ..1.5 m AT A DISTANCE from smoke outlet CONNECTION TO THE FLUE...
  • Page 18 2-INSTALLATION EXAMPLES OF CORRECT INSTALLATION 1. Installation of Ø120mm flue with hole for the passage of the pipe increased by: minimum 100mm around the pipe if next to non flammable parts such as cement, brick, etc.; or minimum 300mm around the pipe (or as required by plate data) if next to flammable parts such as wood etc.
  • Page 19: 3-Drawings And Technical Specifications

    3-DRAWINGS AND TECHNICAL SPECIFICATIONS DRAWINGS AND CHARACTERISTICS FRESIA 70 AIR 9 S1 DIMENSIONS (dimensions in mm) Ø80 Ø80 Technical Dept. - All rights reserved - Reproduction prohibited...
  • Page 20 3-DRAWINGS AND TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FRESIA 70 AIR 9 S1 Energy Efficiency Class Nominal output power 8.8 kW (7568 kcal/h) Minimum power output 2.5 kW (2150 kcal/h) Efficiency at Max 90.6% Efficiency at Min 94.1% Temperature of exhaust smoke at Max 188 °C...
  • Page 21: 4-Unpacking

    4-UNPACKING PREPARATION AND UNPACKING The product is supplied in a single package. Open the package, remove any straps, cardboard and polystyrene and take the appliance off the pallet. To remove the product from the pallet you must extract the movable part of the insert and take out the four Phillips screws securing it to the pallet.
  • Page 22: 5-Overall Dimensions

    5-OVERALL DIMENSIONS FRESIA 70 AIR 9 S1 vedi disegno INSERTO vedi disegno INSERTO FRESIA 70 AIR 9 S1 (Pianta) vedi disegno INSERTO vedi disegno INSERTO INSERT SUPPORT (existing or new) WALL INSULATION SAFETY DISTANCE FROM COMBUSTIBLE MATERIAL*...
  • Page 23 5-OVERALL DIMENSIONS EXAMPLE OF PLACEMENT AT A 90° ANGLE Technical Dept. - All rights reserved - Reproduction prohibited...
  • Page 24 5-OVERALL DIMENSIONS EXAMPLE OF PLACEMENT AT A 45° ANGLE...
  • Page 25: 6-Preliminary Operations

    6-PRELIMINARY OPERATIONS COMBUSTION AIR During operation a certain amount of air is drawn from the room in which the product is installed and this air must be supplemented through an external air inlet. The combustion air “B” in this product is autonomously drawn directly from the front grille, however, the user can have the air drawn from outside by connecting pipe “A”...
  • Page 26 6-PRELIMINARY OPERATIONS PRELIMINARY STEPS Proceed as follows to release the fixed part of the insert: • remove the two nuts “d” and the two washers “r” from the right and left of the insert to make it easier to hold, take the two optional handles “M” and fasten them to the insert •...
  • Page 27 6-PRELIMINARY OPERATIONS • the handles “M” are now fastened on the insert. Hold the two handles “M” and lift the insert • the fixed part “A” is now free and you can fasten it onto the optional support or on an existing surface (as explained in the next pages) Technical Dept.
  • Page 28: 7-Type Of Fastening

    7-TYPE OF FASTENING HOW TO FASTEN THE INSERT It is mandatory to anchor the product to a surface since, during annual maintenance operations by the authorised technician, or when the fuel is loaded, the combustion chamber may be extracted from its seat with the aid of two retractable guides. The product can be anchored to an existing surface (which must have certain characteristics) or it can be fastened to the optional support.
  • Page 29 7-TYPE OF FASTENING Fastening to an existing surface POSITION DESCRIPTION FIXED INSERT PART EXISTING SURFACE ANCHOR BOLT (SEE PREVIOUS PAGE) WASHERS If installing on an existing surface, fitted with grille “G” (see next pages), it is strongly recommended to fasten it according to the diagram.
  • Page 30 7-TYPE OF FASTENING Fastening to the horizontal support Place the base in the desired position (after mounting it as explained in the instructions attached to the accessory) and adjust the height by using the feet (from a min. of 500 mm to a max. of 650 mm). Make sure there is a power socket behind the pedestal so that the plug is accessible after the unit has been installed.
  • Page 31 AIR INTAKE GRILLE IN THE BEST POSITION The best position for the air intake grille “G” is in the centre of the existing firebox with the measurements shown in the table. FRESIA 70 AIR 9 S1 MIN 200 MAX 250 G = AIR INTAKE GRILLE Technical Dept.
  • Page 32 7-TYPE OF FASTENING AIR INTAKE GRILLE ON THE LEFT If the position of the air intake grille “G” is on the left of the firebox, it needs to be changed and moved towards the centre of the firebox in the best position. The opening of the existing firebox must nevertheless have the measurements shown on the previous page. POS.1 PIT H60 mm MIN.
  • Page 33 7-TYPE OF FASTENING FASTENING TO THE EXISTING FIREBOX WITHOUT AIR OPENINGS If the existing firebox does not have any air openings (see next pages), you must use the “Feet kit” accessory (optional). Follow the procedure below to position it: • After separating the fixed part “A”...
  • Page 34 7-TYPE OF FASTENING • position the foot “W” on the surface “S” where the holes are • pick the rubber strip “v” up, remove the adhesive film and fix it under the piece “A” cut to size flush with the outer perimeter of the part “A”...
  • Page 35: 8-Accessories

    8-ACCESSORIES ACCESSORIES COMBUSTION AIR KIT The combustion air kit is used to withdraw combustion air from the outdoor environment. HANDLE KIT The handle kit is used to handle the insert conveniently. WI-FI KIT INSTALLATION (OPTIONAL) Install the Wi-Fi kit (code 4016003), according to the indications in the specific manual, on the back or near the stove using the velcro supplied with the accessory.
  • Page 36 8-ACCESSORIES 4-SIDED FRAME Passe-partout board with option of inserting the control panel. Support Used to position the insert at the required height without using an existing surface. Feet kit To be used if installing with an existing surface to allow the cooling air to flow correctly.
  • Page 37: 9-Assembling The Accessories

    9-ASSEMBLING THE ACCESSORIES ASSEMBLING COMBUSTION AIR KIT To install the combustion air kit, proceed as follows: • Unscrew the two screws “x” to remove the front grille “C” • take the plate “u” from the optional air kit and fasten it to the structure with the two screws “y” so that the front air inlet “B” is closed •...
  • Page 38: 10-Insert Extraction And Loading Pellets In Cold Machine

    10-INSERT EXTRACTION AND LOADING PELLETS IN COLD MACHINE INSERT EXTRACTION AND LOADING PELLETS Insert extraction The insert can be extracted in order to perform routine maintenance (clean the ash pipe at the end of the year) or special maintenance (replacement of electrical parts if the product breaks) Follow the procedure below to extract the insert: •...
  • Page 39 10-INSERT EXTRACTION AND LOADING PELLETS IN COLD MACHINE PELLET LOADING • open the drawer “L” using the cold handle “Z” supplied. The guides of the tray have an end-of-travel that block the mobile part when extracted completely. • Pour the pellets onto the tray either directly from the bag or by using the scoop supplied (A). •...
  • Page 40: 11-Door Opening

    11-DOOR OPENING DOOR OPENING To open the product door “C”, fit the cold handle “Z” into the hole in the handle and pull it towards you. Attention! The firebox door must be closed properly for the stove to work correctly. The door must only be opened with the product switched off and cold.
  • Page 41: 12-Electrical Connection

    12-ELECTRICAL CONNECTION ELECTRICAL CONNECTION First connect the power cable to the rear of the product and then to a wall socket, which must always remain accessible. Should this not be possible, during installation insert suitable devices for disconnection from the power mains, in compliance with national electrical installation standards.
  • Page 42 12-ELECTRICAL CONNECTION ROOM PROBE The room probe is inside the firebox on the door opening side. Check that the room probe bulb is near the holes on the frame.
  • Page 43 12-ELECTRICAL CONNECTION CONTROL PANEL The control panel is supplied with the insert and must be snap fitted in the wall. When the hole is drilled in the wall “W” for the insert, also drill a 160*45 mm hole “T” for the control panel. When making the hole for the panel, keep in mind that the connection cable between the panel and circuit board of the insert is 1.4 m and that the circuit board is on the right of the insert (firebox door opening side).
  • Page 44: 13-Cladding

    13-CLADDING SETTING UP THE CLADDING All product functionalities must be tested before cladding. The company shall not be liable for any damage to the cladding should operating anomalies arise, which were not ascertained before cladding was applied to the product. IT IS MANDATORY to check the seal of all piping the smoke goes through (smoke fitting, gaskets and insert in the flue) before installing the cladding.
  • Page 45 13-CLADDING The machine must be insulated (panel K) so as not to receive air from the hood “Z” and counter- hood “Y”. The ventilation air “3” must only come from the bottom. 2 - rigid or solid filler panel (not mesh) 1 - a grille can be used to vent the hot air accumulated at the top of the product Technical Dept.